Trace element analysis in biological samples by using XRF spectrometry with secondary radiation.

R Cesareo, G Viezzoli.   

Abstract

An x-ray fluorescence method for in vitro analysis of trace elements in biological samples is presented. The method is characterised by the use of an x-ray tube with secondary targets as a monoenergetic radiation source, and by 'infinitely thin' specimens. In the experimental work, different aspects have been examined in order to optimise the sensitivity of the method. It is shown that it is extremely important to use collimators of high purity materials and very pure and thin sample supports. Regarding the geometry, it is pointed out that a collimator between specimen and detector reduces the counting rate caused by scattering in air and other materials. Scattering in the biological matrix is reduced by preconcentration of biological liquids or tissues. The method has been applied to the analysis of blood serum samples. Typical sensitivities for Fe and Rb are 1.6 ng cm-2 and 1.5 ng cm-2 respectively, in a counting time of 10(3) s.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6657741     DOI: 10.1088/0031-9155/28/11/002

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Biomedical applications of photon-induced X-ray fluorescence.

Authors:  R Cesareo
Journal:  Biol Trace Elem Res       Date:  1987-08       Impact factor: 3.738

2.  A detector's eye view (DEV)-based OSEM algorithm for benchtop x-ray fluorescence computed tomography (XFCT) image reconstruction.

Authors:  Luzhen Deng; Md F Ahmed; Sandun Jayarathna; Peng Feng; Biao Wei; Sang Hyun Cho
Journal:  Phys Med Biol       Date:  2019-04-08       Impact factor: 3.609

3.  Near-Field High-Energy Spectroscopic Gamma Imaging Using a Rotation Modulation Collimator.

Authors:  Amy C Sharma; Timothy G Turkington; Georgia D Tourassi; Carey E Floyd
Journal:  Nucl Instrum Methods Phys Res B       Date:  2008-11       Impact factor: 1.377

4.  A Monte Carlo Model of a Benchtop X-Ray Fluorescence Computed Tomography System and Its Application to Validate a Deconvolution-Based X-Ray Fluorescence Signal Extraction Method.

Authors:  Md Foiez Ahmed; Selcuk Yasar; Sang Hyun Cho
Journal:  IEEE Trans Med Imaging       Date:  2018-05-15       Impact factor: 10.048

5.  A Geant4-based Monte Carlo study of a benchtop multi-pinhole X-ray fluorescence computed tomography imaging.

Authors:  Luzhen Deng; Biao Wei; Peng He; Yi Zhang; Peng Feng
Journal:  Int J Nanomedicine       Date:  2018-11-08
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.