Literature DB >> 29988324

Gamma Knife and volumetric modulated arc therapy stereotactic radiosurgery plan quality and OAR sparing comparison for pituitary adenomas and vestibular schwannomas.

Salim Balik1, Samuel Chao1, Gennady Neyman1.   

Abstract

PURPOSE: To compare the plan quality and organs at risk (OAR) sparing of auto-planned volumetric modulated art therapy (VMAT) and Gamma Knife (GK) for stereotactic radiosurgery of pituitary adenomas (PA) and vestibular schwannomas (VS).
METHODS: VMAT radiosurgery plans were made using auto planning tool for eight vestibular schwannoma and eight pituitary adenoma patients previously treated with GK. VMAT plans were made with three non-coplanar arcs using 315, 0 and 45 degrees angles, 6MV FFF energy at 1400 MU/min dose rate and 2.5 mm thick MLC leaves. Both GK and VMAT plans were prescribed to similar isodose lines (50% - 60%).
RESULTS: Respectively for GK and VMAT, the mean Paddick conformity index (PCI) was 0.62 ± 0.08 and 0.67 ± 0.10 (p > 0.05) for PA and 0.72 ± 0.09 and 0.660 ± 0.13 (p > 0.05) for VS; the mean gradient index (GI) was 2.76 ± 0.14 and 3.14 ± 0.40 Gy (p < 0.05) for PA and 3.71 ± 1.83 and 3.60 ± 0.84 Gy (p > 0.05) for VS; mean brainstem maximum dose was 9.13 ± 3.50 Gy and 7.31 ± 2.01 Gy (p > 0.05) for PA and 11.67 ± 4.56 Gy and 12.22 ± 4.55 Gy (p > 0.05) for VS; mean optic nerve maximum dose was 9.66 ± 1.0 Gy and 7.67 ± 2.58 Gy (p < 0.05); mean cochlea mean dose was 7.31 ± 2.7 Gy and 7.23 ± 3.13 Gy (p > 0.05); and mean treatment time was 68 min and 5 min for PA and 40 min and 3 min for VS.
CONCLUSIONS: Auto planning with standard template simplified the planning stage for VMAT and provided clinically acceptable plans. Comparison of GK and VMAT for plan quality and OAR sparing varied across patients but both were overall comparable.

Entities:  

Keywords:  FFF; Gamma Knife; Linac SRS; OAR sparing; SmartArc; VMAT; acoustic schwannoma; auto planning; flattening filter free; pituitary adenoma; plan quality; radiosurgery; vestibular schwannoma

Year:  2018        PMID: 29988324      PMCID: PMC6018045     

Source DB:  PubMed          Journal:  J Radiosurg SBRT


  21 in total

1.  Comparison of radiation dose spillage from the Gamma Knife Perfexion with that from volumetric modulated arc radiosurgery during treatment of multiple brain metastases in a single fraction.

Authors:  Daniel McDonald; John Schuler; Istvan Takacs; Jean Peng; Joseph Jenrette; Kenneth Vanek
Journal:  J Neurosurg       Date:  2014-12       Impact factor: 5.115

2.  Evaluation of the setup margins for cone beam computed tomography-guided cranial radiosurgery: A phantom study.

Authors:  Juan Francisco Calvo Ortega; Wouter Wunderink; David Delgado; Sandra Moragues; Miquel Pozo; Joan Casals
Journal:  Med Dosim       Date:  2016-03-16       Impact factor: 1.482

3.  Single-Isocenter Frameless Volumetric Modulated Arc Radiosurgery for Multiple Intracranial Metastases.

Authors:  Steven K M Lau; Kaveh Zakeri; Xiao Zhao; Ruben Carmona; Erik Knipprath; Daniel R Simpson; Sameer K Nath; Gwe-Ya Kim; Parag Sanghvi; Jona A Hattangadi-Gluth; Clark C Chen; Kevin T Murphy
Journal:  Neurosurgery       Date:  2015-08       Impact factor: 4.654

4.  A clinical comparison of patient setup and intra-fraction motion using frame-based radiosurgery versus a frameless image-guided radiosurgery system for intracranial lesions.

Authors:  Naren Ramakrishna; Florin Rosca; Scott Friesen; Evrim Tezcanli; Piotr Zygmanszki; Fred Hacker
Journal:  Radiother Oncol       Date:  2010-01-28       Impact factor: 6.280

5.  Plan quality and treatment planning technique for single isocenter cranial radiosurgery with volumetric modulated arc therapy.

Authors:  Grant M Clark; Richard A Popple; Brendan M Prendergast; Sharon A Spencer; Evan M Thomas; John G Stewart; Barton L Guthrie; James M Markert; John B Fiveash
Journal:  Pract Radiat Oncol       Date:  2012-01-30

6.  Initial experience with volumetric IMRT (RapidArc) for intracranial stereotactic radiosurgery.

Authors:  Charles S Mayo; Linda Ding; Anthony Addesa; Sidney Kadish; T J Fitzgerald; Richard Moser
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-03-06       Impact factor: 7.038

7.  Dosimetric consequences of translational and rotational errors in frame-less image-guided radiosurgery.

Authors:  Matthias Guckenberger; Johannes Roesch; Kurt Baier; Reinhart A Sweeney; Michael Flentje
Journal:  Radiat Oncol       Date:  2012-04-24       Impact factor: 3.481

8.  Frameless linac-based stereotactic radiosurgery (SRS) for brain metastases: analysis of patient repositioning using a mask fixation system and clinical outcomes.

Authors:  Giuseppe Minniti; Claudia Scaringi; Enrico Clarke; Maurizio Valeriani; Mattia Osti; Riccardo Maurizi Enrici
Journal:  Radiat Oncol       Date:  2011-11-16       Impact factor: 3.481

Review 9.  Radiosurgery with photons or protons for benign and malignant tumours of the skull base: a review.

Authors:  Maurizio Amichetti; Dante Amelio; Giuseppe Minniti
Journal:  Radiat Oncol       Date:  2012-12-14       Impact factor: 3.481

10.  Evaluation of an automated knowledge based treatment planning system for head and neck.

Authors:  Jerome Krayenbuehl; Ian Norton; Gabriela Studer; Matthias Guckenberger
Journal:  Radiat Oncol       Date:  2015-11-10       Impact factor: 3.481

View more
  1 in total

1.  Is there a volume threshold of brain metastases for Linac-based stereotactic radiotherapy?

Authors:  Chieh-Wen Liu; Saeed Ahmed; Tara Gray; Tianjun Ma; Young-Bin Cho; Gennady Neyman; Samuel Chao; John Suh; Ping Xia
Journal:  J Radiosurg SBRT       Date:  2021
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.