Literature DB >> 24674169

Plan quality and treatment planning technique for single isocenter cranial radiosurgery with volumetric modulated arc therapy.

Grant M Clark1, Richard A Popple1, Brendan M Prendergast1, Sharon A Spencer1, Evan M Thomas1, John G Stewart1, Barton L Guthrie2, James M Markert2, John B Fiveash3.   

Abstract

PURPOSE: To demonstrate plan quality and provide a practical, systematic approach to the treatment planning technique for single isocenter cranial radiosurgery with volumetric modulated arc therapy (VMAT; RapidArc, Varian Medical systems, Palo Alto, CA). METHODS AND MATERIALS: Fifteen patients with 1 or more brain metastases underwent single isocenter VMAT radiosurgery. All plans were normalized to deliver 100% of the prescription dose to 99%-100% of the target volume. All targets per plan were treated to the same dose. Plans were created with dose control tuning structures surrounding targets to maximize conformity and dose gradient. Plan quality was evaluated by calculation of conformity index (CI = 100% isodose volume/target volume) and homogeneity index (HI = maximum dose/prescription dose) scores for each target and a Paddick gradient index (GI = 50% isodose volume/100% isodose volume) score for each plan.
RESULTS: The median number of targets per patient was 2 (range, 1-5). The median number of non-coplanar arcs utilized per plan was 2 (range, 1- 4). Single target plans were created with 1 or 2 non-coplanar arcs while multitarget plans utilized 2 to 4 non-coplanar arcs. Prescription doses ranged from 5-16 Gy in 1-5 fractions. The mean conformity index was 1.12 (± SD, 0.13) and the mean HI was 1.44 (± SD, 0.11) for all targets. The mean GI per plan was 3.34 (± SD, 0.42).
CONCLUSIONS: We have outlined a practical approach to cranial radiosurgery treatment planning using the single isocenter VMAT platform. One or 2 arc single isocenter plans are often adequate for treatment of single targets, while 2-4 arcs may be more advantageous for multiple targets. Given the high plan quality and extreme clinical efficiency, this single isocenter VMAT approach will continue to become more prevalent for linac-based radiosurgical treatment of 1 or more intracranial targets and will likely replace multiple isocenter techniques.
Copyright © 2012 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

Entities:  

Year:  2012        PMID: 24674169     DOI: 10.1016/j.prro.2011.12.003

Source DB:  PubMed          Journal:  Pract Radiat Oncol        ISSN: 1879-8500


  62 in total

1.  Distant brain recurrence in patients with five or more newly diagnosed brain metastases treated with focal stereotactic radiotherapy alone.

Authors:  Olivia Claire Barrett; Andrew M McDonald; Jonathan W Thompson; Markus Bredel; Gerald McGwin; Kristen O Riley; John B Fiveash
Journal:  J Radiosurg SBRT       Date:  2017

2.  Single-Isocenter Frameless Volumetric Modulated Arc Radiosurgery for Multiple Intracranial Metastases.

Authors:  Steven K M Lau; Kaveh Zakeri; Xiao Zhao; Ruben Carmona; Erik Knipprath; Daniel R Simpson; Sameer K Nath; Gwe-Ya Kim; Parag Sanghvi; Jona A Hattangadi-Gluth; Clark C Chen; Kevin T Murphy
Journal:  Neurosurgery       Date:  2015-08       Impact factor: 4.654

3.  Intrafraction motion during frameless radiosurgery using Varian HyperArcTM and BrainLab ElementsTM immobilization systems.

Authors:  Amish P Shah; Dylan T Meeks; Twyla R Willoughby; Naren Ramakrishna; Christopher J Warner; Cameron W Swanick; Patrick Kelly; Sanford L Meeks
Journal:  J Radiosurg SBRT       Date:  2020

4.  Evaluation of multiple factors affecting normal brain dose in single-isocenter multiple target radiosurgery.

Authors:  Yu Yuan; Evan M Thomas; Grant A Clark; James M Markert; John B Fiveash; Richard A Popple
Journal:  J Radiosurg SBRT       Date:  2018

5.  Single fraction volumetric modulated arc radiosurgery of brain metastases.

Authors:  A Serna; P P Escolar; V Puchades; F Mata; D Ramos; M A Gómez; A Iglesias; J Salinas; M Alcaraz
Journal:  Clin Transl Oncol       Date:  2015-03-17       Impact factor: 3.405

6.  A Systematic Analysis of 2 Monoisocentric Techniques for the Treatment of Multiple Brain Metastases.

Authors:  Ganesh Narayanasamy; Sotirios Stathakis; Alonso N Gutierrez; Evangelos Pappas; Richard Crownover; John R Floyd; Niko Papanikolaou
Journal:  Technol Cancer Res Treat       Date:  2016-09-09

7.  Comparison of plan quality and delivery time between volumetric arc therapy (RapidArc) and Gamma Knife radiosurgery for multiple cranial metastases.

Authors:  Evan M Thomas; Richard A Popple; Xingen Wu; Grant M Clark; James M Markert; Barton L Guthrie; Yu Yuan; Michael C Dobelbower; Sharon A Spencer; John B Fiveash
Journal:  Neurosurgery       Date:  2014-10       Impact factor: 4.654

8.  Postoperative radiosurgery for the treatment of metastatic brain tumor: Evaluation of local failure and leptomeningeal disease.

Authors:  Paul M Foreman; Bradford E Jackson; Karan P Singh; Andrew K Romeo; Barton L Guthrie; Winfield S Fisher; Kristen O Riley; James M Markert; Christopher D Willey; Markus Bredel; John B Fiveash
Journal:  J Clin Neurosci       Date:  2017-12-14       Impact factor: 1.961

9.  The effect of MLC leaf width in single-isocenter multi-target radiosurgery with volumetric modulated arc therapy.

Authors:  Zhanerke Abisheva; Scott R Floyd; Joseph K Salama; John Kirkpatrick; Fang-Fang Yin; Michael J Moravan; William Giles; Justus Adamson
Journal:  J Radiosurg SBRT       Date:  2019

10.  SBRT treatment of multiple extracranial oligometastases using a single isocenter with distinct optimizations.

Authors:  Michael Trager; Joseph Salama; Fang-Fang Yin; Justus Adamson
Journal:  J Radiosurg SBRT       Date:  2017
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.