Literature DB >> 29988318

Comparison of outcomes of stereotactic body radiation therapy delivered with three different technologies to the lung.

Sameera S Kumar1, Logan Hall1, Xingzhe Li1, Laura Downes1, Andrew Shearer2, Brent J Shelton2, Samuel Gerring1, Ronald C McGarry1.   

Abstract

PURPOSE/
OBJECTIVES: Since the inception of stereotactic body radiation therapy (SBRT), treatment delivery has been performed with volumetric modulated arc therapy (VMAT), helical tomotherapy (HT) and noncoplanar static fields (SF). The purpose of this study is to compare SBRT delivery among these treatment modalities to the lung. MATERIALS/
METHODS: A retrospective review of SBRT treatments of 30 to 60 Gy in 1 to 5 fractions from 2007 to 2015 was performed. Dosimetric parameters included V5, V20, D2cm, gross tumor volume (GTV) and planning target volume (PTV) size and coverage, rib/esophageal minimum/maximum doses, R30Gy, R50%, and the conformality index (CI). Clinical outcomes evaluated included local control, pneumonitis and other toxicities. ANOVA, Student's t-test and Kruskal-Wallis test were used to compare the parameters among modalities. Kaplan-Meier estimates of time-to-local failure were produced.
RESULTS: 176 Treatments included 106 SF, 36 VMAT and 34 HT. HT had better PTV coverage (p=0.0166) but higher lung V5 and esophageal doses (p<0.001 and p=0.0032). R30Gy, R50%, and CI were significantly better with VMAT SBRT (p<0.001). Clinically, Grade 2+ pneumonitis was associated with larger median GTV's of 21.39 cc versus 7.65 cc (p=0.0016), larger median PTV's of 65.62 cc versus 31.75 cc (p=0.0030), and higher V20 6.62% versus 4.08% (p=0.0408). For patients surviving >1 year, overall local failure rate was 9.4%. Actuarial control rates trended toward statistical significance with time to local failure with VMAT being the most favorable group on the Kaplan-Meier curve (p=0.0733).
CONCLUSION: VMAT showed superior conformality compared to the other modalities. Among the modalities examined, HT had higher values for parameters associated with toxicity such as V5 and maximum esophageal dose, but all were within acceptable limits. There was a trend to better local control with VMAT.

Entities:  

Keywords:  SBRT; Tomotherapy; VMAT; linear accelerator; outcomes

Year:  2018        PMID: 29988318      PMCID: PMC6018041     

Source DB:  PubMed          Journal:  J Radiosurg SBRT


  22 in total

1.  Stereotactic body radiation therapy for inoperable early stage lung cancer.

Authors:  Robert Timmerman; Rebecca Paulus; James Galvin; Jeffrey Michalski; William Straube; Jeffrey Bradley; Achilles Fakiris; Andrea Bezjak; Gregory Videtic; David Johnstone; Jack Fowler; Elizabeth Gore; Hak Choy
Journal:  JAMA       Date:  2010-03-17       Impact factor: 56.272

2.  Radiological and clinical pneumonitis after stereotactic lung radiotherapy: a matched analysis of three-dimensional conformal and volumetric-modulated arc therapy techniques.

Authors:  David A Palma; Suresh Senan; Cornelis J A Haasbeek; Wilko F A R Verbakel; Andrew Vincent; Frank Lagerwaard
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-06-26       Impact factor: 7.038

3.  Stereotactic radiotherapy for peripheral lung tumors: a comparison of volumetric modulated arc therapy with 3 other delivery techniques.

Authors:  Chin Loon Ong; Wilko F A R Verbakel; Johan P Cuijpers; Ben J Slotman; Frank J Lagerwaard; Suresh Senan
Journal:  Radiother Oncol       Date:  2010-11-11       Impact factor: 6.280

4.  Dose--volume metrics associated with radiation pneumonitis after stereotactic body radiation therapy for lung cancer.

Authors:  Yukinori Matsuo; Keiko Shibuya; Mitsuhiro Nakamura; Masaru Narabayashi; Katsuyuki Sakanaka; Nami Ueki; Ken Miyagi; Yoshiki Norihisa; Takashi Mizowaki; Yasushi Nagata; Masahiro Hiraoka
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-03-19       Impact factor: 7.038

5.  A planning comparison of 3-dimensional conformal multiple static field, conformal arc, and volumetric modulated arc therapy for the delivery of stereotactic body radiotherapy for early stage lung cancer.

Authors:  Mike Dickey; Wilson Roa; Suzanne Drodge; Sunita Ghosh; Brad Murray; Rufus Scrimger; Zsolt Gabos
Journal:  Med Dosim       Date:  2015-05-28       Impact factor: 1.482

6.  Analysis of stage and clinical/prognostic factors for lung cancer from SEER registries: AJCC staging and collaborative stage data collection system.

Authors:  Vivien W Chen; Bernardo A Ruiz; Mei-Chin Hsieh; Xiao-Cheng Wu; Lynn A G Ries; Denise R Lewis
Journal:  Cancer       Date:  2014-12-01       Impact factor: 6.860

7.  Dose as a function of lung volume and planned treatment volume in helical tomotherapy intensity-modulated radiation therapy-based stereotactic body radiation therapy for small lung tumors.

Authors:  Joseph M Baisden; Davis A Romney; Andrew G Reish; Jing Cai; Ke Sheng; David R Jones; Stanley H Benedict; Paul W Read; James M Larner
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-05-21       Impact factor: 7.038

8.  Volumetric modulated arc therapy with flattening filter free (FFF) beams for stereotactic body radiation therapy (SBRT) in patients with medically inoperable early stage non small cell lung cancer (NSCLC).

Authors:  Pierina Navarria; Anna Maria Ascolese; Pietro Mancosu; Filippo Alongi; Elena Clerici; Angelo Tozzi; Cristina Iftode; Giacomo Reggiori; Stefano Tomatis; Maurizio Infante; Marco Alloisio; Alberto Testori; Antonella Fogliata; Luca Cozzi; Emanuela Morenghi; Marta Scorsetti
Journal:  Radiother Oncol       Date:  2013-05-28       Impact factor: 6.280

9.  Dosimetric comparison of three-dimensional conformal radiotherapy, intensity modulated radiotherapy, and helical tomotherapy for lung stereotactic body radiotherapy.

Authors:  Rajesh Ashok Kinhikar; Yogesh G Ghadi; Priyadarshini Sahoo; Sarbani Ghosh Laskar; Deepak D Deshpande; Shyam K Shrivastava; Jaiprakash Agarwal
Journal:  J Med Phys       Date:  2015 Oct-Dec

10.  Critical structure sparing in stereotactic ablative radiotherapy for central lung lesions: helical tomotherapy vs. volumetric modulated arc therapy.

Authors:  Alexander Chi; Pan Ma; Guishan Fu; Gerry Hobbs; James S Welsh; Nam P Nguyen; Si Young Jang; Jinrong Dai; Jing Jin; Ritsuko Komaki
Journal:  PLoS One       Date:  2013-04-05       Impact factor: 3.240

View more
  2 in total

1.  Optimal prescription isodose line in SBRT for lung tumor treatment with volumetric-modulated arc therapy.

Authors:  David Wang; Albert DeNittis; Tracey Evans; Thomas Meyer
Journal:  J Radiosurg SBRT       Date:  2020

2.  Outcomes Following Stereotactic Body Radiotherapy with Intensity-Modulated Therapy versus Three-Dimensional Conformal Radiotherapy in Early Stage Non-Small Cell Lung Cancer.

Authors:  Michael Mix; Sean Tanny; Tamara Nsouli; Ryan Alden; Rishabh Chaudhari; Russell Kincaid; Paula F Rosenbaum; Jeffrey A Bogart; Paul Aridgides
Journal:  Lung Cancer (Auckl)       Date:  2019-12-20
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.