| Literature DB >> 26865754 |
Rajesh Ashok Kinhikar1, Yogesh G Ghadi1, Priyadarshini Sahoo1, Sarbani Ghosh Laskar2, Deepak D Deshpande1, Shyam K Shrivastava2, Jaiprakash Agarwal2.
Abstract
To compare the treatment plans generated with three-dimensional conformal radiation therapy (3DCRT), intensity modulated radiotherapy (IMRT), and helical tomotherapy (HT) for stereotactic body radiotherapy of lung, twenty patients with medically inoperable (early nonsmall cell lung cancer) were retrospectively reviewed for dosimetric evaluation of treatment delivery techniques (3DCRT, IMRT, and HT). A dose of 6 Gy per fraction in 8 fractions was prescribed to deliver 95% of the prescription dose to 95% volume of planning target volume (PTV). Plan quality was assessed using conformity index (CI) and homogeneity index (HI). Doses to critical organs were assessed. Mean CI with 3DCRT, IMRT, and HT was 1.19 (standard deviation [SD] 0.13), 1.18 (SD 0.11), and 1.08 (SD 0.04), respectively. Mean HI with 3DCRT, IMRT, and HT was 1.14 (SD 0.05), 1.08 (SD 0.02), and 1.07 (SD 0.04), respectively. Mean R50% values for 3DCRT, IMRT, and HT was 8.5 (SD 0.35), 7.04 (SD 0.45), and 5.43 (SD 0.29), respectively. D2cm was found superior with IMRT and HT. Significant sparing of critical organs can be achieved with highly conformal techniques (IMRT and HT) without compromising the PTV conformity and homogeneity.Entities:
Keywords: Helical tomotherapy; intensity modulated radiotherapy; lung stereotactic body radiotherapy; three-dimensional conformal radiation therapy; treatment planning
Year: 2015 PMID: 26865754 PMCID: PMC4728889 DOI: 10.4103/0971-6203.170792
Source DB: PubMed Journal: J Med Phys ISSN: 0971-6203
Figure 1From top to bottom: Three-dimensional conformal radiation therapy, intensity modulated radiotherapy, and helical tomotherapy. Axial, coronal, and sagittal views from one representative patient. Projected isodose wash 107%, 100%, 95%, and 50% isodoses
DVH based analysis for PTV for 20 patients
DVH based analysis for Lung-PTV for 20 patients
DVH based analysis for organs at risk for 20 patients
Figure 2Conformity index for planning target volume with three-dimensional conformal radiation therapy, intensity modulated radiotherapy, and helical tomotherapy for 20 patients
Figure 3Homogeneity index for planning target volume with three-dimensional conformal radiation therapy, intensity modulated radiotherapy, and helical tomotherapy for 20 patients
Statistical validation with paired sample t-test (two-tailed)