Literature DB >> 26027510

A planning comparison of 3-dimensional conformal multiple static field, conformal arc, and volumetric modulated arc therapy for the delivery of stereotactic body radiotherapy for early stage lung cancer.

Mike Dickey1, Wilson Roa2, Suzanne Drodge2, Sunita Ghosh3, Brad Murray1, Rufus Scrimger2, Zsolt Gabos4.   

Abstract

The primary objective of this study was to compare dosimetric variables as well as treatment times of multiple static fields (MSFs), conformal arcs (CAs), and volumetric modulated arc therapy (VMAT) techniques for the treatment of early stage lung cancer using stereotactic body radiotherapy (SBRT). Treatments of 23 patients previously treated with MSF of 48Gy to 95% of the planning target volume (PTV) in 4 fractions were replanned using CA and VMAT techniques. Dosimetric parameters of the Radiation Therapy Oncology Group (RTOG) 0915 trial were evaluated, along with the van׳t Riet conformation number (CN), monitor units (MUs), and actual and calculated treatment times. Paired t-tests for noninferiority were used to compare the 3 techniques. CA had significant dosimetric improvements over MSF for the ratio of the prescription isodose volume to PTV (R100%, p < 0.0001), the maximum dose 2cm away from the PTV (D2cm, p = 0.005), and van׳t Riet CN (p < 0.0001). CA was not statistically inferior to MSF for the 50% prescription isodose volume to PTV (R50%, p = 0.05). VMAT was significantly better than CA for R100% (p < 0.0001), R50% (p < 0.0001), D2cm (p = 0.006), and CN (p < 0.0001). CA plans had significantly shorter treatment times than those of VMAT (p < 0.0001). Both CA and VMAT planning showed significant dosimetric improvements and shorter treatment times over those of MSF. VMAT showed the most favorable dosimetry of all 3 techniques; however, the dosimetric effect of tumor motion was not evaluated. CA plans were significantly faster to treat, and minimize the interplay of tumor motion and dynamic multileaf collimator (MLC) motion effects. Given these results, CA has become the treatment technique of choice at our facility.
Copyright © 2015 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Stereotactic body radiotherapy; non-small cell lung cancer; treatment delivery; volumetric modulated arc therapy

Mesh:

Year:  2015        PMID: 26027510     DOI: 10.1016/j.meddos.2015.04.006

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  8 in total

1.  Evaluating which plan quality metrics are appropriate for use in lung SBRT.

Authors:  Ravindra Yaparpalvi; Madhur K Garg; Jin Shen; William R Bodner; Dinesh K Mynampati; Aleiya Gafar; Hsiang-Chi Kuo; Amar K Basavatia; Nitin Ohri; Linda X Hong; Shalom Kalnicki; Wolfgang A Tome
Journal:  Br J Radiol       Date:  2018-01-10       Impact factor: 3.039

2.  Development of a novel detection method for changes in lung conditions during radiotherapy using a temporal subtraction technique.

Authors:  Yoshinori Tanabe; Takayuki Ishida
Journal:  Phys Eng Sci Med       Date:  2021-10-26

3.  Comparison of outcomes of stereotactic body radiation therapy delivered with three different technologies to the lung.

Authors:  Sameera S Kumar; Logan Hall; Xingzhe Li; Laura Downes; Andrew Shearer; Brent J Shelton; Samuel Gerring; Ronald C McGarry
Journal:  J Radiosurg SBRT       Date:  2018

4.  Stereotactic body radiotherapy for primary non-small cell lung cancer patients with clinical T3-4N0M0 (UICC 8th edition): outcomes and patterns of failure.

Authors:  Atsuya Narita; Atsuya Takeda; Takahisa Eriguchi; Yusuke Saigusa; Naoko Sanuki; Yuichiro Tsurugai; Tatsuji Enomoto; Hidehiko Kuribayashi; Tomikazu Mizuno; Kae Yashiro; Yu Hara; Takeshi Kaneko
Journal:  J Radiat Res       Date:  2019-10-23       Impact factor: 2.724

5.  Verification of an optimizer algorithm by the beam delivery evaluation of intensity-modulated arc therapy plans.

Authors:  Tamas Pocza; Domonkos Szegedi; Tibor Major; Csilla Pesznyak
Journal:  Radiol Oncol       Date:  2021-11-19       Impact factor: 2.991

Review 6.  Special stereotactic radiotherapy techniques: procedures and equipment for treatment simulation and dose delivery.

Authors:  Lisa Paoletti; Corrado Ceccarelli; Claudia Menichelli; Cynthia Aristei; Simona Borghesi; Enrico Tucci; Paolo Bastiani; Salvatore Cozzi
Journal:  Rep Pract Oncol Radiother       Date:  2022-03-22

7.  Fractionated stereotactic radiotherapy of benign skull-base tumors: a dosimetric comparison of volumetric modulated arc therapy with Rapidarc® versus non-coplanar dynamic arcs.

Authors:  Fanny Martin; Florian Magnier; Lucie Berger; Jessica Miroir; Emmanuel Chautard; Pierre Verrelle; Michel Lapeyre; Julian Biau
Journal:  Radiat Oncol       Date:  2016-04-18       Impact factor: 3.481

8.  A dosimetric and treatment efficiency evaluation of stereotactic body radiation therapy for peripheral lung cancer using flattening filter free beams.

Authors:  Ji-Yong Zhang; Jia-Yang Lu; Li-Li Wu; Dan-Li Hong; Chang-Chun Ma; Xun Peng; Zhi-Xiong Lin
Journal:  Oncotarget       Date:  2016-11-08
  8 in total