Literature DB >> 29988268

Prospective Evaluation of Lesion Index-Guided Pulmonary Vein Isolation Technique in Patients with Paroxysmal Atrial Fibrillation: 1-year Follow-Up.

Luca De Mattia1, Martino Crosato1, Stefano Indiani2, Elena Causin1, Claudia Licciardello2, Paolo Antonio Maria Squasi1, Alessandro De Leo1, Vittorio Calzolari1.   

Abstract

INTRODUCTION: Pulmonary vein isolation (PVI) using contact force (CF) sensing ablation catheters currently relies on CF and force-time integral (FTI) guidelines. Such measurement of lesion effectiveness still lacks information on current delivery to the tissue, influenced by system impedance and power. Lesion Index (LSI) is a multi-parametric index incorporating CF and radiofrequency current data across time. We aimed to prospectively assess the efficacy of an LSI-guided approach to PVI in patients with paroxysmal atrial fibrillation (PAF). METHODS AND
RESULTS: The study prospectively enrolled 28 consecutive patients with PAF undergoing PVI with a CF sensing catheter (TactiCathTM, Abbott). LSI-guided ablation target was adapted according to the mean regional thickness of pulmonary vein antra (PVA): LSI range 5.5-6 was pursued in the anterior and septal portions of PVA, 5-5.5 elsewhere. Data from 32 consecutive PAF patients who underwent PVI ablation with a non-CF guided approach (NCF-group) were retrospectively collected for comparison of procedural and clinical outcome.AF-free survival rate at follow-up (17±6 months) was higher for LSI-guided group than NCF-group (89.3% vs 65.6%, p=0.037), with no increase in periprocedural complication rate (no tamponades or other major adverse events reported). Among 1126 lesions with LSI within target range (5-6), average CF was >10g and <30g for 976 lesions (86.7%). Moreover, 1015 lesions (90.1%) had FTI>400gs, but with wide distribution: 30.2% within 400-500gs, 30.0% within 501-600gs, 29.9% over 600gs.
CONCLUSION: In this first prospective study, LSI-guided PVI improved clinical outcome without any increase in complication rate when compared with standard, non-LSI-guided approach.

Entities:  

Keywords:  Contact Force; Lesion Index; RadioFrequency Ablation

Year:  2018        PMID: 29988268      PMCID: PMC6009787          DOI: 10.4022/jafib.1858

Source DB:  PubMed          Journal:  J Atr Fibrillation        ISSN: 1941-6911


  19 in total

1.  Area under the real-time contact force curve (force-time integral) predicts radiofrequency lesion size in an in vitro contractile model.

Authors:  Dipen C Shah; Hendrik Lambert; Hiroshi Nakagawa; Arne Langenkamp; Nicolas Aeby; Giovanni Leo
Journal:  J Cardiovasc Electrophysiol       Date:  2010-09

2.  Electromagnetic Contact-Force Sensing Electrophysiological Catheters: How Accurate is the Technology?

Authors:  Felix Bourier; Gabriele Hessling; Sonia Ammar-Busch; Marc Kottmaier; Alessandra Buiatti; Christian Grebmer; Marta Telishevska; Verena Semmler; Carsten Lennerz; Christine Schneider; Christof Kolb; Isabel Deisenhofer; Tilko Reents
Journal:  J Cardiovasc Electrophysiol       Date:  2016-01-11

3.  Variation in left atrial transmural wall thickness at sites commonly targeted for ablation of atrial fibrillation.

Authors:  Burr Hall; Vinodh Jeevanantham; Rochelle Simon; John Filippone; Gabriel Vorobiof; James Daubert
Journal:  J Interv Card Electrophysiol       Date:  2007-01-17       Impact factor: 1.900

4.  Paroxysmal AF catheter ablation with a contact force sensing catheter: results of the prospective, multicenter SMART-AF trial.

Authors:  Andrea Natale; Vivek Y Reddy; George Monir; David J Wilber; Bruce D Lindsay; H Thomas McElderry; Charan Kantipudi; Moussa C Mansour; Daniel P Melby; Douglas L Packer; Hiroshi Nakagawa; Baohui Zhang; Robert B Stagg; Lee Ming Boo; Francis E Marchlinski
Journal:  J Am Coll Cardiol       Date:  2014-08-19       Impact factor: 24.094

5.  Fiberoptic Contact-Force Sensing Electrophysiological Catheters: How Precise Is the Technology?

Authors:  Felix Bourier; Carola Gianni; Matthew Dare; Isabel Deisenhofer; Gabriele Hessling; Tilko Reents; Sanghamitra Mohanty; Chintan Trivedi; Andrea Natale; Amin Al-Ahmad
Journal:  J Cardiovasc Electrophysiol       Date:  2016-10-24

6.  Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation.

Authors:  Riccardo Cappato; Hugh Calkins; Shih-Ann Chen; Wyn Davies; Yoshito Iesaka; Jonathan Kalman; You-Ho Kim; George Klein; Andrea Natale; Douglas Packer; Allan Skanes; Federico Ambrogi; Elia Biganzoli
Journal:  Circ Arrhythm Electrophysiol       Date:  2009-12-07

7.  The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study.

Authors:  Vivek Y Reddy; Dipen Shah; Josef Kautzner; Boris Schmidt; Nadir Saoudi; Claudia Herrera; Pierre Jaïs; Gerhard Hindricks; Petr Peichl; Aude Yulzari; Hendrik Lambert; Petr Neuzil; Andrea Natale; Karl-Heinz Kuck
Journal:  Heart Rhythm       Date:  2012-07-20       Impact factor: 6.343

8.  Importance of catheter contact force during irrigated radiofrequency ablation: evaluation in a porcine ex vivo model using a force-sensing catheter.

Authors:  Aravinda Thiagalingam; Andre D'Avila; Lori Foley; J Luis Guerrero; Hendrik Lambert; Giovanni Leo; Jeremy N Ruskin; Vivek Y Reddy
Journal:  J Cardiovasc Electrophysiol       Date:  2010-02-01

9.  Response of atrial fibrillation to pulmonary vein antrum isolation is directly related to resumption and delay of pulmonary vein conduction.

Authors:  Atul Verma; Fethi Kilicaslan; Ennio Pisano; Nassir F Marrouche; Raffaele Fanelli; Johannes Brachmann; Jens Geunther; Domenico Potenza; David O Martin; Jennifer Cummings; J David Burkhardt; Walid Saliba; Robert A Schweikert; Andrea Natale
Journal:  Circulation       Date:  2005-08-02       Impact factor: 29.690

10.  Randomized, Controlled Trial of the Safety and Effectiveness of a Contact Force-Sensing Irrigated Catheter for Ablation of Paroxysmal Atrial Fibrillation: Results of the TactiCath Contact Force Ablation Catheter Study for Atrial Fibrillation (TOCCASTAR) Study.

Authors:  Vivek Y Reddy; Srinivas R Dukkipati; Petr Neuzil; Andrea Natale; Jean-Paul Albenque; Josef Kautzner; Dipen Shah; Gregory Michaud; Marcus Wharton; David Harari; Srijoy Mahapatra; Hendrik Lambert; Moussa Mansour
Journal:  Circulation       Date:  2015-08-10       Impact factor: 29.690

View more
  12 in total

1.  Lesion index: a novel guide in the path of successful pulmonary vein isolation.

Authors:  Antonio Dello Russo; Gaetano M Fassini; Michela Casella; Elena Romanelli; Salvatore Pala; Stefania Riva; Valentina Catto; Massimo Moltrasio; Fabrizio Tundo; Martina Zucchetti; Benedetta Majocchi; Maria Antonietta Dessanai; Francesca Pizzamiglio; Giulia Vettor; Valentina Ribatti; Alessio Gasperetti; Selene Cellucci; Gabriele Negro; Rita Sicuso; Corrado Carbucicchio; Claudio Tondo
Journal:  J Interv Card Electrophysiol       Date:  2018-12-04       Impact factor: 1.900

2.  Higher than recommended lesion size index target values for pulmonary vein isolation result in better clinical outcomes in paroxysmal atrial fibrillation patients.

Authors:  Josip Katić; Ante Anić; Toni Brešković; Zrinka Jurišić
Journal:  J Interv Card Electrophysiol       Date:  2021-08-28       Impact factor: 1.759

3.  Monitoring of irrigated lesion formation with single fiber based multispectral system using machine learning.

Authors:  Soo Young Park; Rajinder P Singh-Moon; Haiqiu Yang; Christine P Hendon
Journal:  J Biophotonics       Date:  2022-06-15       Impact factor: 3.390

4.  Catheter ablation for atrial fibrillation in a low-volume center using contemporary technology.

Authors:  Julian Cheong Kiat Tay; Xinzhe James Cai; Jing Lin; Shufen Liang; Ai Ling Him; Sherida Binte Syed Hamid; Kelvin Cheok Keng Wong; Colin Yeo; Vern Hsen Tan
Journal:  Int J Cardiol Heart Vasc       Date:  2020-10-23

Review 5.  Catheter ablation for atrial fibrillation: current indications and evolving technologies.

Authors:  Ramanathan Parameswaran; Ahmed M Al-Kaisey; Jonathan M Kalman
Journal:  Nat Rev Cardiol       Date:  2020-10-13       Impact factor: 32.419

Review 6.  The challenge of optimising ablation lesions in catheter ablation of ventricular tachycardia.

Authors:  Riccardo Proietti; Luca Lichelli; Nicolas Lellouche; Tarvinder Dhanjal
Journal:  J Arrhythm       Date:  2020-12-28

7.  Quantification of irrigated lesion morphology using near-infrared spectroscopy.

Authors:  Soo Young Park; Rajinder Singh-Moon; Haiqiu Yang; Deepak Saluja; Christine Hendon
Journal:  Sci Rep       Date:  2021-10-11       Impact factor: 4.379

8.  Optimal Lesion Size Index for Pulmonary Vein Isolation in High-Power Radiofrequency Catheter Ablation of Atrial Fibrillation.

Authors:  Chi Cai; Jing Wang; Hong-Xia Niu; Jian-Min Chu; Wei Hua; Shu Zhang; Yan Yao
Journal:  Front Cardiovasc Med       Date:  2022-04-07

9.  High-power, short-duration ablation in the coronary sinus: clinical cases and preliminary observations on swine hearts.

Authors:  Chengming Ma; Xiaomeng Yin; Yunlong Xia; Jiao Sun; Shiyu Dai; Lianjun Gao; Xianjie Xiao; Yuanjun Sun; Rongfeng Zhang; Yingxue Dong; Zhongzhen Wang; Xiaohong Yu
Journal:  J Interv Card Electrophysiol       Date:  2021-04-15       Impact factor: 1.900

10.  Optimized lesion size index (o-LSI): A novel predictor for sufficient ablation of pulmonary vein isolation.

Authors:  Gen Matsuura; Jun Kishihara; Hidehira Fukaya; Jun Oikawa; Naruya Ishizue; Daiki Saito; Tetsuro Sato; Yuki Arakawa; Shuhei Kobayashi; Yuki Shirakawa; Ryo Nishinarita; Ai Horiguchi; Shinichi Niwano; Junya Ako
Journal:  J Arrhythm       Date:  2021-04-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.