Impact of advanced detector technology and iterative reconstruction on low-dose quantitative assessment of lung computed tomography density in a biological lung model.

E Hammond1,2, K S Chan3, J C Ames1, N Stoyles1, C M Sloan1, J Guo1,2, J D Newell1,2, E A Hoffman1,2, J C Sieren1,2.   

Abstract

PURPOSE: Quantitative computed tomography (QCT)-derived measures of lung density are valued methods for objectively characterizing lung parenchymal and peripheral airways disease and are being used in a growing number of lung disease focused trials. Detector and reconstruction improvements in CT technology have allowed for significant radiation dose reduction in image acquisition with comparable qualitative image quality. We report the impact of detector type and reconstruction type on QCT lung density measures in relation to decreasing dose indices.
METHODS: Two sets of studies were completed in an in vivo pig model with a SOMATOM Definition Flash CT system: (a) prior to system upgrade with conventional detectors (UFC) and filtered back projection (FBP), and (b) post system upgrade with integrated electronic detectors (STELLAR) and iterative reconstruction (SAFIRE). CT data were acquired across estimated CT volume dose indices (CTDIvol ) ranging from 0.75 to 15 mGy at both inspiratory and expiratory breath holds. Semiautomated lung segmentations allowed calculation of histogram median, kurtosis, and 15th percentile. Percentage of voxels below -910 HU and -950 HU (inspiratory), and -856 HU (expiratory) were also examined. The changes in these QCT metrics from dose reduction (15 mGy down to 0.75 mGy) were calculated relative to paired reference values (15 mGy). Results were compared based on detector and reconstruction type.
RESULTS: In this study, STELLAR detectors improved concordance with 15 mGy values down to 3 mGy for inspiratory scans and 6 mGy for expiratory scans. The addition of SAFIRE reconstruction in all acquired measurements resulted in minimal deviation from reference values at 0.75 mGy.
CONCLUSION: The use of STELLAR integrated electronic detectors and SAFIRE iterative reconstruction may allow for comparable lung density measures with CT dose indices down to 0.75 mGy.
© 2018 American Association of Physicists in Medicine.

Entities:  

Keywords:  air-trapping; emphysema; low-dose computed tomography; lung density measures; quantitative computed tomography

Year:  2018        PMID: 29926932      PMCID: PMC6309498          DOI: 10.1002/mp.13057

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  28 in total

1.  Stress relaxation of the human lung.

Authors:  R MARSHALL; J G WIDDICOMBE
Journal:  Clin Sci       Date:  1961-02       Impact factor: 6.124

2.  Design of the Subpopulations and Intermediate Outcomes in COPD Study (SPIROMICS).

Authors:  David Couper; Lisa M LaVange; MeiLan Han; R Graham Barr; Eugene Bleecker; Eric A Hoffman; Richard Kanner; Eric Kleerup; Fernando J Martinez; Prescott G Woodruff; Stephen Rennard
Journal:  Thorax       Date:  2013-09-12       Impact factor: 9.139

3.  Air trapping on expiratory high-resolution CT scans in the absence of inspiratory scan abnormalities: correlation with pulmonary function tests and differential diagnosis.

Authors:  H Arakawa; W R Webb
Journal:  AJR Am J Roentgenol       Date:  1998-05       Impact factor: 3.959

4.  A model of lung parenchyma stress relaxation using fractional viscoelasticity.

Authors:  Zoujun Dai; Ying Peng; Hansen A Mansy; Richard H Sandler; Thomas J Royston
Journal:  Med Eng Phys       Date:  2015-06-03       Impact factor: 2.242

5.  Relationships between diffusing capacity for carbon monoxide (DLCO), and quantitative computed tomography measurements and visual assessment for chronic obstructive pulmonary disease.

Authors:  Atsushi Nambu; Jordan Zach; Joyce Schroeder; Gong Yong Jin; Song Soo Kim; Yu-Il Kim; Christina Schnell; Russell Bowler; David A Lynch
Journal:  Eur J Radiol       Date:  2015-01-22       Impact factor: 3.528

Review 6.  The Role of Chest Computed Tomography in the Evaluation and Management of the Patient with Chronic Obstructive Pulmonary Disease.

Authors:  Wassim W Labaki; Carlos H Martinez; Fernando J Martinez; Craig J Galbán; Brian D Ross; George R Washko; R Graham Barr; Elizabeth A Regan; Harvey O Coxson; Eric A Hoffman; John D Newell; Douglas Curran-Everett; James C Hogg; James D Crapo; David A Lynch; Ella A Kazerooni; MeiLan K Han
Journal:  Am J Respir Crit Care Med       Date:  2017-12-01       Impact factor: 21.405

7.  Genetic epidemiology of COPD (COPDGene) study design.

Authors:  Elizabeth A Regan; John E Hokanson; James R Murphy; Barry Make; David A Lynch; Terri H Beaty; Douglas Curran-Everett; Edwin K Silverman; James D Crapo
Journal:  COPD       Date:  2010-02       Impact factor: 2.409

8.  Repeatability and Sample Size Assessment Associated with Computed Tomography-Based Lung Density Metrics.

Authors:  Krishna S Iyer; Randall W Grout; Gideon K Zamba; Eric A Hoffman
Journal:  Chronic Obstr Pulm Dis       Date:  2014

9.  Image Noise, CNR, and Detectability of Low-Contrast, Low-Attenuation Liver Lesions in a Phantom: Effects of Radiation Exposure, Phantom Size, Integrated Circuit Detector, and Iterative Reconstruction.

Authors:  Ajit H Goenka; Brian R Herts; Frank Dong; Nancy A Obuchowski; Andrew N Primak; Wadih Karim; Mark E Baker
Journal:  Radiology       Date:  2016-03-02       Impact factor: 11.105

Review 10.  Quantitative computed tomography in COPD: possibilities and limitations.

Authors:  O M Mets; P A de Jong; B van Ginneken; H A Gietema; J W J Lammers
Journal:  Lung       Date:  2011-12-17       Impact factor: 2.584

View more
  5 in total

Review 1.  Origins of and lessons from quantitative functional X-ray computed tomography of the lung.

Authors:  Eric A Hoffman
Journal:  Br J Radiol       Date:  2022-03-01       Impact factor: 3.629

2.  Menstrual cycle impacts lung structure measures derived from quantitative computed tomography.

Authors:  Jessica C Sieren; Kimberly E Schroeder; Junfeng Guo; Kewal Asosingh; Serpil Erzurum; Eric A Hoffman
Journal:  Eur Radiol       Date:  2021-12-20       Impact factor: 7.034

3.  Factors Affecting Radiation Dose in Computed Tomography Angiograms for Pulmonary Embolism: A Retrospective Cohort Study.

Authors:  Prashant Nagpal; Sarv Priya; Ali Eskandari; Aidan Mullan; Tanya Aggarwal; Sabarish Narayanasamy; Kamesh Parashar; Ambarish P Bhat; Jessica C Sieren
Journal:  J Clin Imaging Sci       Date:  2020-11-13

4.  Personalized Chest Computed Tomography: Minimum Diagnostic Radiation Dose Levels for the Detection of Fibrosis, Nodules, and Pneumonia.

Authors:  Matthias May; Rafael Heiss; Julia Koehnen; Matthias Wetzl; Marco Wiesmueller; Christoph Treutlein; Lars Braeuer; Michael Uder; Markus Kopp
Journal:  Invest Radiol       Date:  2022-03-01       Impact factor: 6.016

5.  Case Studies in Physiology: Temporal variations of the lung parenchyma and vasculature in asymptomatic COVID-19 pneumonia: a multispectral CT assessment.

Authors:  Prashant Nagpal; Amin Motahari; Sarah E Gerard; Junfeng Guo; Joseph M Reinhardt; Alejandro P Comellas; Eric A Hoffman; David W Kaczka
Journal:  J Appl Physiol (1985)       Date:  2021-06-24
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.