Evaluation of a new photon-counting imaging detector (PCD) with various acquisition modes.

A Shankar1, J Krebs1, D R Bednarek1, S Rudin1.   

Abstract

The prospect of improved low noise, high speed, and dual-energy imaging that may be associated with the use of photon-counting imaging detectors (PCD) has motivated this evaluation of a newly upgraded version of a prototype PCD. The XCounter Actaeon was evaluated in its four acquisition modes each based upon varying signal processing firmware including a mode with charge sharing correction that enables neighboring pixels that share the energy from one incident x-ray photon detection to be counted only once at the proper summed energy in the pixel with the largest charge deposition. Since this PCD is a CdTe-based direct detector with 100 μm pixels, such charge sharing for typical medical x-ray energy photons may occur frequently and must be corrected to achieve more accurate counts. This charge sharing correction is achieved with an Anti-Coincidence Circuit (ACC) which prevents double pixel counting from one event as well as prevents counting from either event if they are below a preset threshold. Various physical parameters of the PCD were evaluated including linearity, sensitivity, pulse pile-up effects, dark noise, spatial resolution, noise power spectrum, and detective quantum efficiency.

Entities:  

Keywords:  Detector Quantum Efficiency (DQE); Modulation Transfer Function (MTF); Noise Power Spectrum (NPS); Photon Counting Detectors (PCD)

Year:  2018        PMID: 29881136      PMCID: PMC5987190          DOI: 10.1117/12.2294629

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  4 in total

1.  Intercomparison of methods for image quality characterization. I. Modulation transfer function.

Authors:  Ehsan Samei; Nicole T Ranger; James T Dobbins; Ying Chen
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

Review 2.  Vision 20/20: Single photon counting x-ray detectors in medical imaging.

Authors:  Katsuyuki Taguchi; Jan S Iwanczyk
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

3.  A method for measuring the presampled MTF of digital radiographic systems using an edge test device.

Authors:  E Samei; M J Flynn; D A Reimann
Journal:  Med Phys       Date:  1998-01       Impact factor: 4.071

4.  Assessment of a photon-counting detector for a dual-energy C-arm angiographic system.

Authors:  Moiz Ahmad; Rebecca Fahrig; Leland Pung; Martin Spahn; Niko S Köster; Silke Reitz; Teri Moore; Jang-Hwan Choi; Waldo Hinshaw; Yan Xia; Kerstin Müller
Journal:  Med Phys       Date:  2017-09-22       Impact factor: 4.071

  4 in total
  5 in total

1.  Flow-Pattern Details in an Aneurysm Model Using High-Speed 1000-Frames-per-Second Angiography.

Authors:  J M Krebs; A Shankar; S V Setlur Nagesh; J M Davies; K V Snyder; E I Levy; L N Hopkins; M Mokin; D R Bednarek; A H Siddiqui; S Rudin
Journal:  AJNR Am J Neuroradiol       Date:  2019-06-06       Impact factor: 3.825

2.  Gantry rotational motion-induced blur in cone-beam computed tomography.

Authors:  J Krebs; A Shankar; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2018-03-09

3.  Simultaneous Biplane High Speed 1000 fps X-ray Angiography (HSAngio).

Authors:  S V Setlur Nagesh; A Shields; X Wu; C Ionita; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2022-04-04

4.  Comparison of quantitative imaging characteristics between a new, larger-FOV 1000 fps high-speed angiographic (HSA) photon-counting detector (Aries) with a smaller HSA detector (Actaeon).

Authors:  X Wu; A Shields; S V Setlur Nagesh; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2021-04-04

5.  Spectroscopy with a CdTe-based photon-counting imaging detector (PCD) having charge sharing correction capability.

Authors:  A Shankar; J Krebs; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2018-03-09
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.