Literature DB >> 31171521

Flow-Pattern Details in an Aneurysm Model Using High-Speed 1000-Frames-per-Second Angiography.

J M Krebs1, A Shankar1, S V Setlur Nagesh1,2, J M Davies3,2,4,5, K V Snyder1,3,2,6,5, E I Levy1,3,2,7,5, L N Hopkins1,3,2,7,5, M Mokin8, D R Bednarek1,2,7, A H Siddiqui1,3,2,7,5, S Rudin9,10,11,12,3,2,7.   

Abstract

Traditional digital subtraction angiography provides rather limited evaluation of contrast flow dynamics when studying and treating intracranial brain aneurysms. A 1000-frames-per-second photon-counting x-ray detector was used to image detailed iodine-contrast flow patterns in an internal carotid artery aneurysm of a 3D-printed vascular phantom. High-speed imaging revealed differences in vortex and inflow patterns with and without a Pipeline Embolization Device flow diverter in more detail and clarity than could be seen in standard pulsed angiography. Improved temporal imaging has the potential to impact the outcomes of endovascular interventions by allowing clinicians to better understand and act on flow dynamics in real-time.
© 2019 by American Journal of Neuroradiology.

Entities:  

Mesh:

Year:  2019        PMID: 31171521      PMCID: PMC7048558          DOI: 10.3174/ajnr.A6090

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  5 in total

1.  Evaluation of a new photon-counting imaging detector (PCD) with various acquisition modes.

Authors:  A Shankar; J Krebs; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2018-03-09

2.  Use of the microangiographic fluoroscope for coiling of intracranial aneurysms.

Authors:  Mandy J Binning; David Orion; Parham Yashar; Sharon Webb; Ciprian N Ionita; Amit Jain; Stephen Rudin; L Nelson Hopkins; Adnan H Siddiqui; Elad I Levy
Journal:  Neurosurgery       Date:  2011-11       Impact factor: 4.654

3.  Hemodynamics of Flow Diverters.

Authors:  Ronak Dholakia; Chander Sadasivan; David J Fiorella; Henry H Woo; Baruch B Lieber
Journal:  J Biomech Eng       Date:  2017-02-01       Impact factor: 2.097

4.  Treatment Planning for Image-Guided Neuro-Vascular Interventions Using Patient-Specific 3D Printed Phantoms.

Authors:  M Russ; R O'Hara; S V Setlur Nagesh; M Mokin; C Jimenez; A Siddiqui; D Bednarek; S Rudin; C Ionita
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-03-19

5.  Computational fluid dynamics simulations of intracranial aneurysms at varying heart rates: a "patient-specific" study.

Authors:  Jingfeng Jiang; Charles Strother
Journal:  J Biomech Eng       Date:  2009-09       Impact factor: 2.097

  5 in total
  3 in total

1.  2D vessel contrast dilution gradient (CDG) analysis using 1000 fps high speed angiography (HSA) for velocity distribution estimation.

Authors:  Kyle A Williams; Allison Shields; S V Setlur Nagesh; Daniel R Bednarek; Stephen Rudin; Ciprian N Ionita
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2022-04-04

2.  Use of 1000fps High Speed X-ray Angiography (HSAngio) to quantify differences in flow diversion effects of three stents with different coverage densities in a cerebral aneurysm invitro model.

Authors:  S V Setlur Nagesh; A Shields; X Wu; C Ionita; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2022-04-04

3.  Initial investigations of scatter cross-talk in simultaneous biplane high-speed 1000 frames per second neuro-angiography using Monte Carlo simulations.

Authors:  J Troville; R S Dhonde; A Shields; S Rudin; D R Bednarek
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2022-04-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.