Jin Hwan Ahn1, Taeg Su Ko2, Yong Seuk Lee3, Hwa Jae Jeong1, Jong Kuen Park1.
Abstract
BACKGROUND: Cortical suspensory femoral fixation is commonly performed for graft fixation to the femur in anterior cruciate ligament (ACL) reconstruction using hamstring tendons. The purpose of this study was to compare graft healing in the femoral tunnel, implant-related failure, and clinical results between fixed- and adjustable-length loop devices in outside-in ACL reconstruction.Entities:
Keywords: Anterior cruciate ligament; Femoral tunnel; Graft healing; Suspensory fixation device
Mesh:
Year: 2018 PMID: 29854338 PMCID: PMC5964263 DOI: 10.4055/cios.2018.10.2.157
Source DB: PubMed Journal: Clin Orthop Surg ISSN: 2005-291X
Demographic and Clinical Characteristics of the Patients
| Variable | Fixed-loop group | Adjustable-loop group | |
|---|---|---|---|
| Demographic characteristic | n = 48 | n = 61 | |
| Female sex | 9 (18.8) | 10 (16.4) | 0.803 |
| Age (yr) | 30.7 ± 10.6 | 32.6 ± 10.8 | 0.489 |
| Postoperative MRI follow-up (mo) | 6.6 ± 0.6 | 6.4 ± 0.8 | 0.135 |
| Clinical characteristic | n = 22 | n = 17 | |
| Preoperative IKDC subjective score | 53.2 ± 19.5 | 51.2 ± 24.7 | 0.778 |
| Preoperative Tegner and Lysholm activity scale | 63.0 ± 21.0 | 52.2 ± 23.0 | 0.134 |
| Preoperative IKDC objective score | 0.034 | ||
| A | 0 | 0 | |
| B | 0 | 4 (23.5) | |
| C | 16 (72.7) | 7 (41.2) | |
| D | 6 (27.3) | 6 (35.3) | |
| Preoperative Lachman test | 0.091 | ||
| Negative | 0 | 0 | |
| 1+ | 1 (4.6) | 0 | |
| 2+ | 5 (22.7) | 9 (52.9) | |
| 3+ | 16 (72.7) | 8 (47.1) | |
| Preoperative Pivot shift test | 0.164 | ||
| Negative | 0 | 0 | |
| 1+ | 2 (9.1) | 6 (35.3) | |
| 2+ | 17 (77.3) | 9 (52.9) | |
| 3+ | 3 (13.6) | 2 (11.8) | |
| Clinical follow-up (mo) | 29.4 ± 7.9 | 26.9 ± 5.6 | 0.289 |
| Follow-up for more than 2 years | 22 (45.8) | 17 (27.9) | 0.052 |
Values are presented as number (%) or mean ± standard deviation.
MRI: magnetic resonance imaging, IKDC: International Knee Documentation Committee.
Fig. 1Patient flowchart. ACL: anterior cruciate ligament.
Fig. 2Postoperative X-ray. (A) Fixedlength loop device. (B) Adjustable-length loop device.
Fig. 3Coronal oblique T2-weighted magnetic resonance imaging. (A) Presence of synovial fluid case. (B) Absence of fluid case. Arrow: presence of synovial fluid at the exit of femoral tunnel.
Fig. 4Signal intensity of anterior cruciate ligament graft using the signal-to-noise quotient. (A) Tunnel aperture. (B) Tunnel midsection. (C) Tunnel exit. Arrow: tendon-bone interface, arrowhead: tendon graft.
Comparison of Mean SNR Values in the Femoral Bone Tunnel between Total Patients and Patients Available for Last Clinical Follow-up in Each Group
| Variable | Fixed-loop group | Adjustable-loop group | ||||
|---|---|---|---|---|---|---|
| Total patients (n = 48) | Follow-up patients (n = 22) | Total patients (n = 61) | Follow-up patients (n = 17) | |||
| Tunnel aperture | ||||||
| Tendon graft | 11.8 ± 8.6 | 12.3 ± 10.7 | 0.844 | 14.5 ± 17.1 | 11.8 ± 5.3 | 0.324 |
| Tendon-bone interface | 11.9 ± 7.9 | 10.4 ± 7.6 | 0.461 | 12.6 ± 6.3 | 12.0 ± 5.7 | 0.379 |
| Tunnel midsection | ||||||
| Tendon graft | 12.2 ± 9.2 | 12.0 ± 11.2 | 0.937 | 11.3 ± 7.4 | 10.0 ± 6.0 | 0.675 |
| Tendon-bone interface | 14.0 ± 9.5 | 12.4 ± 11.0 | 0.552 | 14.3 ± 7.0 | 13.5 ± 6.6 | 0.507 |
| Tunnel exit | ||||||
| Tendon graft | 11.5 ± 10.2 | 10.8 ± 12.9 | 0.813 | 10.4 ± 7.2 | 8.7 ± 6.3 | 0.722 |
| Tendon-bone interface | 15.6 ± 11.3 | 15.0 ± 13.8 | 0.833 | 17.3 ± 7.5 | 15.3 ± 7.9 | 0.523 |
Values are presented as mean ± standard deviation.
SNR: signal-to-noise ratio.
Comparison of Mean SNR Values in the Femoral Bone Tunnel between the Fixed-Loop Group and the Adjustable-Loop Group
| Variable | Fixed-loop group (n = 48) | Adjustable-loop group (n = 61) | 95% CI | |
|---|---|---|---|---|
| Tunnel aperture | ||||
| Tendon graft | 11.8 ± 8.6 | 14.5 ± 17.1 | −8.1 to 2.7 | 0.320 |
| Tendon-bone interface | 11.9 ± 7.9 | 12.6 ± 6.3 | −3.4 to 2.0 | 0.620 |
| Tunnel midsection | ||||
| Tendon graft | 12.2 ± 9.2 | 11.3 ± 7.4 | −2.3 to 4.0 | 0.603 |
| Tendon-bone interface | 14.0 ± 9.5 | 14.3 ± 7.0 | −3.5 to 2.8 | 0.824 |
| Tunnel exit | ||||
| Tendon graft | 11.5 ± 10.1 | 10.4 ± 7.2 | −2.2 to 4.4 | 0.517 |
| Tendon-bone interface | 15.6 ± 11.3 | 17.3 ± 7.5 | −5.3 to 1.8 | 0.341 |
Values are presented as mean ± standard deviation.
SNR: signal-to-noise ratio, CI: confidence interval.
Fig. 5A wide gap between the graft end and the exit of the femoral bone tunnel. Arrow: length of wide gap.
Clinical Results at Last Follow-up between the Fixed-Loop Group and the Adjustable-Loop Group
| Variable | Fixed-loop group (n = 22) | Adjustable-loop group (n = 17) | |
|---|---|---|---|
| IKDC subjective score | 79.43 ± 12.0 | 78.6 ± 17.7 | 0.931 |
| Tegner-Lysholm score | 82.3 ± 13.3 | 85.7 ± 17.3 | 0.624 |
| IKDC objective score | 0.973 | ||
| A | 14 (63.6) | 11 (64.7) | |
| B | 7 (31.8) | 5 (29.4) | |
| C | 1 (4.6) | 1 (5.9) | |
| D | 0 | 0 | |
| Lachman test | 0.240 | ||
| Negative | 16 (72.7) | 15 (88.2) | |
| 1+ | 6 (27.3) | 2 (11.8) | |
| 2+ | 0 | 0 | |
| 3+ | 0 | 0 | |
| Pivot shift test | 0.587 | ||
| Negative | 18 (81.8) | 15 (88.2) | |
| 1+ | 4 (18.2) | 2 (11.8) | |
| 2+ | 0 | 0 | |
| 3+ | 0 | 0 |
Values are presented as mean ± standard deviation or number (%).
IKDC: International Knee Documentation Committee.