Literature DB >> 27881383

Clinical and Radiological Outcomes After Hamstring Anterior Cruciate Ligament Reconstructions: Comparison Between Fixed-Loop and Adjustable-Loop Cortical Suspension Devices.

Nam-Hong Choi1, Bong-Seok Yang2, Brian N Victoroff3.   

Abstract

BACKGROUND: Few studies have compared clinical and radiological outcomes after hamstring anterior cruciate ligament (ACL) reconstruction with fixed-loop and adjustable-loop cortical suspension devices. Purpose/Hypothesis: The purpose of this retrospective study was to compare clinical outcomes and tunnel widening after hamstring ACL reconstructions with fixed- and adjustable-loop cortical suspension devices. The hypothesis was that compared with femoral graft fixation with the fixed-loop device, fixation with the adjustable-loop device would show similar clinical outcomes and would result in less tunnel widening after hamstring ACL reconstruction. STUDY
DESIGN: Cohort study; Level of evidence, 3.
METHODS: A total of 117 consecutive patients underwent hamstring ACL reconstruction at a single institution. The fixed-loop cortical suspension device was used in 67 patients, and the adjustable-loop cortical suspension device was used in 50 patients. All patients were observed for a minimum of 2 years. Postoperative knee laxity was evaluated with the Lachman test, pivot-shift test, and KT-1000 arthrometer. Functional evaluations were performed by use of the Lysholm score and the Tegner activity scale. On anteroposterior (AP) and lateral radiographs, the measured diameters of the femoral tunnel at 1 year after surgery were compared with the diameter of the reamer used at surgery. The measured diameters of the tibial tunnel at 1 year after surgery were compared with those taken immediately after surgery.
RESULTS: The mean KT-1000 arthrometer laxity measurement was 1.5 ± 1.8 mm in the fixed-loop group and 1.2 ± 2.3 mm in the adjustable-loop group ( P = .530). Results of postoperative knee laxity evaluations and functional outcomes from both groups showed no statistically significant differences. However, the fixed-loop group showed significantly better stability in the pivot-shift test than did the adjustable-loop group ( P = .018). On AP radiographs, the mean diameter of the femoral and tibial tunnels increased by 42.2% ± 15.9% and 37.0% ± 17.8%, respectively, in the fixed-loop group and by 43.0% ± 15.4% and 36.8% ± 18.2% in the adjustable-loop group. On lateral radiographs, the mean diameter of the femoral and tibial tunnels increased by 38.1% ± 14.8% and 39.9% ± 13.8%, respectively, in the fixed-loop group and by 35.8% ± 12.2% and 38.1% ± 21.0% in the adjustable-loop group. No significant differences were found between the 2 groups in postoperative femoral and tibial tunnel widening on AP radiographs ( P = .801 and .951, respectively) or lateral radiographs ( P = .422 and .621, respectively).
CONCLUSION: Compared with femoral fixation by use of the fixed-loop device, femoral fixation by use of the adjustable-loop device showed similar clinical outcomes but did not reduce tunnel widening after hamstring ACL reconstructions.

Entities:  

Keywords:  adjustable-loop; anterior cruciate ligament reconstruction; cortical suspension device; fixed-loop; hamstring; tunnel widening

Mesh:

Year:  2016        PMID: 27881383     DOI: 10.1177/0363546516674183

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  24 in total

1.  Increased lateral tibial posterior slope is related to tibial tunnel widening after primary ACL reconstruction.

Authors:  Soheil Sabzevari; Amir Ata Rahnemai-Azar; Humza S Shaikh; Justin W Arner; James J Irrgang; Freddie H Fu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-03-04       Impact factor: 4.342

2.  Adjustable buttons for ACL graft cortical fixation partially fail with cyclic loading and unloading.

Authors:  J Glasbrenner; C Domnick; M J Raschke; T Willinghöfer; C Kittl; P Michel; D Wähnert; Mirco Herbort
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-10-27       Impact factor: 4.342

3.  ACL hamstring grafts fixed using adjustable cortical suspension in both the femur and tibia demonstrate healing and integration on MRI at one year.

Authors:  Sven Putnis; Thomas Neri; Samuel Grasso; James Linklater; Brett Fritsch; David Parker
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-06-17       Impact factor: 4.342

4.  A survey on prognosis of anterior cruciate ligament (ACL) reconstruction surgeries following fixed loop and adjustable loop methods.

Authors:  Pedram Yavari; Ghasem Mohammadsharifi; Behrooz Fadaei; Sina Talebi; Morteza Akbari
Journal:  Int J Physiol Pathophysiol Pharmacol       Date:  2020-12-15

5.  Adjustable-loop implants are non-inferior to fixed-loop implants for femoral fixation in anterior cruciate ligament reconstruction.

Authors:  Simone B Elmholt; Torsten G Nielsen; Martin Lind
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2022-06-23       Impact factor: 4.342

6.  [Lengths of the fixed loop and the adjustable loop in the coarse bone tunnel were compared to influence the widening of the femoral bone tunnel and the function of the knee joint].

Authors:  Y Yin; Y Mei; Z G Wang; S Y Song; P F Liu; P F He; W J Wu; X Xie
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2021-10-18

7.  Anterior Cruciate Ligament Reconstruction: A Comparative Clinical Study Between Adjustable and Fixed Length Suspension Devices.

Authors:  Bastian Uribe-Echevarria; Justin A Magnuson; Annunziato Amendola; Matthew J Bollier; Brian R Wolf; Carolyn M Hettrich
Journal:  Iowa Orthop J       Date:  2020

8.  Graft isometry during anatomical ACL reconstruction has little effect on surgical outcomes.

Authors:  Hyun-Soo Moon; Chong-Hyuk Choi; Je-Hyun Yoo; Min Jung; Tae-Ho Lee; Kee-Bum Hong; Sung-Hwan Kim
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2021-07-15       Impact factor: 4.342

9.  Laterally shifted tibial tunnel can be the risk of residual knee laxity for double-bundle anterior cruciate ligament reconstruction.

Authors:  Daisuke Chiba; Yuji Yamamoto; Yuka Kimura; Shizuka Sasaki; Eiji Sasaki; Shohei Yamauchi; Eiichi Tsuda; Yasuyuki Ishibashi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2021-04-30       Impact factor: 4.342

Review 10.  Adjustable Loop Femoral Cortical Suspension Devices for Anterior Cruciate Ligament Reconstruction: A Systematic Review.

Authors:  Sarvpreet Singh; Shalin Shaunak; Sebastian C K Shaw; John L Anderson; Vipul Mandalia
Journal:  Indian J Orthop       Date:  2020-01-13       Impact factor: 1.251

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.