| Literature DB >> 34141595 |
Yoshimasa Ono1,2, Yusuke Sato1, Hiroki Mukai3, Takahiro Enomoto1, Seiji Kimura1, Ryosuke Nakagawa1, Ryuichiro Akagi1, Yosuke Inaba4, Yohei Kawasaki4, Seiji Ohtori1, Takahisa Sasho1,2.
Abstract
BACKGROUND: In double-bundle anterior cruciate ligament reconstruction (ACLR), fixed-loop and adjustable-loop cortical suspensory devices are commonly used to fix the soft graft on the femoral side. However, few studies have compared in vivo elongation of the two devices. The purpose of this study was to determine whether EndoButton CL (EB) and TightRope RT (TR), the suspensory fixation devices used in ACLR, maintained their length in vivo from the time of surgery through the postoperative period in a randomized controlled trial.Entities:
Keywords: Adjustable loop; Anterior cruciate ligament reconstruction; Cortical suspensory fixation device; Fixed loop
Year: 2021 PMID: 34141595 PMCID: PMC8184406 DOI: 10.1016/j.asmart.2021.05.007
Source DB: PubMed Journal: Asia Pac J Sports Med Arthrosc Rehabil Technol ISSN: 2214-6873
Fig. 1Schematic and MRI measurements of the distance from the reconstructed ligament to the lateral cortical bone of the femur. Red line: Distance between the lateral cortical surface of the femur and the tip of graft; Blue line: Axis of the femoral tunnel; Yellow line: Axis perpendicular to femoral tunnel axis. (For interpretation of the references to colour in this figure legend, the reader is referred to the Web version of this article.)
Fig. 2CONSORT flow diagram. EB, EndoButton; TR, TightRope. (This figure is uploaded separately.)
Patient characteristics and preoperative evaluation.
| Preoperative characteristics | EndoButton CL | TightRope RT | |
|---|---|---|---|
| Age (years) | 25.2 ± 9.6 | 25.7 ± 8.4 | 0.88 |
| Sex (male/female) | 6/7 | 8/7 | 0.70 |
| Side (right/left) | 3/10 | 10/5 | 0.03 |
| Lachman test grade (1/2/3) | 2/10/1 | 1/12/2 | 0.83 |
| Lateral pivot shift test (+/-) | 12/1 | 15/0 | 0.46 |
| Lysholm score | 69.7 ± 22.4 | 71.6 ± 19.3 | 0.70 |
Mean ± standard deviation.
Elongation from immediately after surgery to three, six and twelve months after surgery.
| Time elapsed and bundles | EB group (mm) | TR group (mm) | TR – EB (mm) | ||
|---|---|---|---|---|---|
| 3 months | |||||
| AM bundle (95% CI) | −0.04 (−0.93, 0.85) | −0.29 (−0.87, 0.30) | −0.24 (−1.26, 0.77) | 0.61 | |
| PL bundle (95% CI) | 0.43 (−0.50, 1.37) | −0.23 (−0.91, 0.46) | −0.66 (−1.73, 0.41) | 0.21 | |
| 6 months | |||||
| AM bundle (95% CI) | 0.53 (−0.48, 1.53) | −0.002 (−0.89, 0.85) | −0.54 (−1.80, 0.71) | 0.19 | |
| PL bundle (95% CI) | 0.80 (0.003, 1.60) | 0.12 (−0.84, 1.07) | −0.68 (−1.86, 0.49) | 0.23 | |
| 12 months | |||||
| AM bundle (95% CI) | 0.85 (−0.48, 2.19) | 1.05 (0.07, 2.03) | 0.20 (−1.33, 1.72) | 0.26 | |
| PL bundle (95% CI) | 0.66 (−0.14, 1.46) | 0.41 (−0.23, 1.04) | −0.25 (−1.21, 0.71) | 0.59 | |
AM, anteromedial; PL, posterolateral; CI, confidence interval.
Clinical evaluation one year after surgery.
| Items examined | EndoButton CL | TightRope RT | |
|---|---|---|---|
| HOP index | 0.90 ± 0.13 | 0.83 ± 0.19 | 0.27 |
| KSM-100 (mm) | 0.5 ± 1.7 | 1.0 ± 2.5 | 0.51 |
| Lachman test grade (1/2) | 12/1 | 12/3 | 0.60 |
| Lateral pivot shift test (+/-) | 13/0 | 14/1 | 1.00 |
| Lysholm score | 94.9 ± 8.3 | 86.7 ± 13.3 | 0.07 |
Mean ± standard deviation.