Quantitative assessment of variation in CBCT image technical parameters related to CBCT detector lateral-offset position.

Gustavo Machado Santaella1, Pedro Luiz Rosalen2, Polyane Mazucatto Queiroz1, Francisco Haiter-Neto1, Ann Wenzel3, Rubens Spin-Neto3.   

Abstract

OBJECTIVES: To assess the effect of CBCT detector position (aligned/lateral-offset) on image technical parameters (mean voxel value - MVV, standard deviation of voxel value (SDVV) distribution), comparing peripheral regions of interest (ROIs) to the central ROI in CBCT volumes.
METHODS: 40 CBCT volumes of a wax phantom were acquired in six units with aligned and/or lateral-offset detectors: Cranex 3Dx (CRA), Ortophos SL (ORT), Picasso Trio (PIC), Promax 3D Mid (PRO), Scanora 3D (SCA), and X1. Four image-acquisition protocols used an aligned detector, and four a lateral-offset detector. In each volume, 13 ROIs (12 peripheral and 1 central) were evaluated. MVV and SDVV of the peripheral ROI were compared to those of the central ROI in the volume. MVVD (the difference in percentage, between the MVV of a peripheral and the central ROI) was calculated.
RESULTS: For aligned-detectors, MVV increased (ORT and PRO) or decreased (CRA and X1) in the ROIs farther from the centre. For lateral-offset detectors, ROIs farther from the centre showed increased MVV. SDVV for most aligned detectors was lower, the nearer the ROI was to the centre. For lateral-offset detectors, it was lower for the peripheral ROIs, except with PIC. Range for MVVD was -32.8% to 22.8% for units with aligned detectors, and -20.7% to 69.5% for lateral-offset detectors.
CONCLUSION: Lateral-offset detectors to acquire CBCT images significantly change SDVV distribution within the field-of-view, and lead to MVVD with increased range, compared to aligned detectors. This must be taken in consideration in the clinic, if voxel-value dependent measurements are to be performed.

Entities:  

Keywords:  cone beam computed tomography; quality control

Mesh:

Year:  2019        PMID: 31469317      PMCID: PMC7026930          DOI: 10.1259/dmfr.20190077

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  17 in total

1.  Effective doses from cone beam CT investigation of the jaws.

Authors:  J Davies; B Johnson; Na Drage
Journal:  Dentomaxillofac Radiol       Date:  2012-01       Impact factor: 2.419

Review 2.  Flat-detector computed tomography (FD-CT).

Authors:  Willi A Kalender; Yiannis Kyriakou
Journal:  Eur Radiol       Date:  2007-06-23       Impact factor: 5.315

3.  Prospects and challenges of rendering tissue density in Hounsfield units for cone beam computed tomography.

Authors:  Roberto Molteni
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol       Date:  2013-07

4.  What is cone-beam CT and how does it work?

Authors:  William C Scarfe; Allan G Farman
Journal:  Dent Clin North Am       Date:  2008-10

5.  Comparison of the accuracy of full head cone beam CT images obtained using a large field of view and stitched images.

Authors:  Mehmet Ozgur Ozemre; Ayse Gulsahi
Journal:  Dentomaxillofac Radiol       Date:  2018-06-19       Impact factor: 2.419

6.  CBCT volumetric coverage extension using a pair of complementary circular scans with complementary kV detector lateral and longitudinal offsets.

Authors:  Deshan Yang; H Harold Li; S Murty Goddu; Jun Tan
Journal:  Phys Med Biol       Date:  2014-10-08       Impact factor: 3.609

7.  An ex vivo study of automated motion artefact correction and the impact on cone beam CT image quality and interpretability.

Authors:  Rubens Spin-Neto; Louise H Matzen; Lars W Schropp; Thomas S Sørensen; Ann Wenzel
Journal:  Dentomaxillofac Radiol       Date:  2018-03-22       Impact factor: 2.419

8.  Effect of anatomical region on the formation of metal artefacts produced by dental implants in cone beam computed tomographic images.

Authors:  Alessiana Helena Machado; Karolina Aparecida Castilho Fardim; Camila Furtado de Souza; Bruno Salles Sotto-Maior; Neuza Maria Souza Picorelli Assis; Karina Lopes Devito
Journal:  Dentomaxillofac Radiol       Date:  2018-01-10       Impact factor: 2.419

Review 9.  Cone Beam Computed Tomographic imaging in orthodontics.

Authors:  W C Scarfe; B Azevedo; S Toghyani; A G Farman
Journal:  Aust Dent J       Date:  2017-03       Impact factor: 2.291

10.  Reduction of scatter-induced image noise in cone beam computed tomography: effect of field of view size and position.

Authors:  Ruben Pauwels; Reinhilde Jacobs; Ria Bogaerts; Hilde Bosmans; Soontra Panmekiate
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol       Date:  2015-10-20
View more
  1 in total

1.  Impact of movement and motion-artefact correction on image quality and interpretability in CBCT units with aligned and lateral-offset detectors.

Authors:  Gustavo Machado Santaella; Ann Wenzel; Francisco Haiter-Neto; Pedro Luiz Rosalen; Rubens Spin-Neto
Journal:  Dentomaxillofac Radiol       Date:  2019-09-24       Impact factor: 2.419

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.