Literature DB >> 29850116

Contemporary applications of intra-aortic balloon counterpulsation for cardiogenic shock: a "real world" experience.

Federico Pappalardo1, Silvia Ajello1, Massimiliano Greco2, Małgorzata Celińska-Spodar3, Michele De Bonis4, Alberto Zangrillo1, Andrea Montisci5.   

Abstract

BACKGROUND: Intra-aortic balloon pump (IABP) had a pivotal role in the therapy of cardiogenic shock (CS), but recent studies have questioned its effects on patients' outcome. Aim of this study is the description of a "real world" series of patients in which IABP was used as a primary mechanical circulatory support (MCS).
METHODS: All patients who received IABP in our institution during 1 year were prospectively enrolled in our study. The outcomes were: ICU mortality, length of ICU stay, factors associated with mortality and complications of IABP. A logistic regression model was developed to estimate the effect of several risk factors on mortality.
RESULTS: A total of 119 patients were enrolled, 54 patients underwent IABP placement for CS unrelated to cardiac surgery (medical CS) and 65 after open-heart surgery. There was no significant difference for mortality between medical CS [12/54 (22.2%)] and cardiac surgery [7/65 (10.8%)] (P=0.09). The morbidity rate related to IABP was 11.3%. Multivariable analysis identified AKI (OR =9.3; 95% CI, 2.0-40.0; P=0.004), inotropic score at the time of IABP implantation (OR =1.06; 95% CI, 1.01-1.11; P=0.009) and history of myocardial revascularization (OR =4.7; 95% CI, 1.1-20.2; P=0.036) as independent predictors for early death (P<0.05). A ROC curve analysis for inotropic score at time of implantation and mortality was performed in the overall population [AUC=0.78 (95% CI, 0.66-0.90)]. A cutoff of 20 has a specificity =72% and sensitivity=74% in this population.
CONCLUSIONS: Mortality is similar in medical and postcardiotomy CS. The benefits of IABP are limited if the amount of inotropes and the severity of shock are too high.

Entities:  

Keywords:  Cardiac surgery; heart failure; inotropic agents; postoperative care; postoperative complications

Year:  2018        PMID: 29850116      PMCID: PMC5949499          DOI: 10.21037/jtd.2018.04.20

Source DB:  PubMed          Journal:  J Thorac Dis        ISSN: 2072-1439            Impact factor:   2.895


  23 in total

1.  Prognosis after the implantation of an intra-aortic balloon pump in cardiac surgery calculated with a new score.

Authors:  Harald Hausmann; Evgenij V Potapov; Andreas Koster; Thomas Krabatsch; Julia Stein; Ruhi Yeter; Marian Kukucka; Ralf Sodian; Hermann Kuppe; Roland Hetzer
Journal:  Circulation       Date:  2002-09-24       Impact factor: 29.690

2.  Guidelines for the echocardiographic assessment of the right heart in adults: a report from the American Society of Echocardiography endorsed by the European Association of Echocardiography, a registered branch of the European Society of Cardiology, and the Canadian Society of Echocardiography.

Authors:  Lawrence G Rudski; Wyman W Lai; Jonathan Afilalo; Lanqi Hua; Mark D Handschumacher; Krishnaswamy Chandrasekaran; Scott D Solomon; Eric K Louie; Nelson B Schiller
Journal:  J Am Soc Echocardiogr       Date:  2010-07       Impact factor: 5.251

3.  Recommendations for chamber quantification: a report from the American Society of Echocardiography's Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology.

Authors:  Roberto M Lang; Michelle Bierig; Richard B Devereux; Frank A Flachskampf; Elyse Foster; Patricia A Pellikka; Michael H Picard; Mary J Roman; James Seward; Jack S Shanewise; Scott D Solomon; Kirk T Spencer; Martin St John Sutton; William J Stewart
Journal:  J Am Soc Echocardiogr       Date:  2005-12       Impact factor: 5.251

4.  ESC Guidelines for the management of acute myocardial infarction in patients presenting with ST-segment elevation.

Authors:  Ph Gabriel Steg; Stefan K James; Dan Atar; Luigi P Badano; Carina Blömstrom-Lundqvist; Michael A Borger; Carlo Di Mario; Kenneth Dickstein; Gregory Ducrocq; Francisco Fernandez-Aviles; Anthony H Gershlick; Pantaleo Giannuzzi; Sigrun Halvorsen; Kurt Huber; Peter Juni; Adnan Kastrati; Juhani Knuuti; Mattie J Lenzen; Kenneth W Mahaffey; Marco Valgimigli; Arnoud van 't Hof; Petr Widimsky; Doron Zahger
Journal:  Eur Heart J       Date:  2012-08-24       Impact factor: 29.983

5.  Intra-aortic balloon counterpulsation in acute myocardial infarction complicated by cardiogenic shock (IABP-SHOCK II): final 12 month results of a randomised, open-label trial.

Authors:  Holger Thiele; Uwe Zeymer; Franz-Josef Neumann; Miroslaw Ferenc; Hans-Georg Olbrich; Jörg Hausleiter; Antoinette de Waha; Gert Richardt; Marcus Hennersdorf; Klaus Empen; Georg Fuernau; Steffen Desch; Ingo Eitel; Rainer Hambrecht; Bernward Lauer; Michael Böhm; Henning Ebelt; Steffen Schneider; Karl Werdan; Gerhard Schuler
Journal:  Lancet       Date:  2013-09-03       Impact factor: 79.321

Review 6.  Preoperative intra aortic balloon pumps in patients undergoing coronary artery bypass grafting.

Authors:  Thomas Theologou; Mohamad Bashir; Arvind Rengarajan; Omar Khan; Tom Spyt; David Richens; Mark Field
Journal:  Cochrane Database Syst Rev       Date:  2011-01-19

7.  The carina as a useful radiographic landmark for positioning the intraaortic balloon pump.

Authors:  Jin-Tae Kim; Jeong-Rim Lee; Jae-Kwang Kim; Seung Zhoo Yoon; Yunseok Jeon; Jae-Hyon Bahk; Ki-Bong Kim; Chong-Sung Kim; Young-Jin Lim; Hee-Soo Kim; Seong-Deok Kim
Journal:  Anesth Analg       Date:  2007-09       Impact factor: 5.108

8.  Intraaortic balloon support for myocardial infarction with cardiogenic shock.

Authors:  Holger Thiele; Uwe Zeymer; Franz-Josef Neumann; Miroslaw Ferenc; Hans-Georg Olbrich; Jörg Hausleiter; Gert Richardt; Marcus Hennersdorf; Klaus Empen; Georg Fuernau; Steffen Desch; Ingo Eitel; Rainer Hambrecht; Jörg Fuhrmann; Michael Böhm; Henning Ebelt; Steffen Schneider; Gerhard Schuler; Karl Werdan
Journal:  N Engl J Med       Date:  2012-08-26       Impact factor: 91.245

Review 9.  Intraaortic balloon pump use in high-risk percutaneous coronary intervention.

Authors:  Sumeet Sharma; Matthew Lumley; Divaka Perera
Journal:  Curr Opin Cardiol       Date:  2013-11       Impact factor: 2.161

10.  Does intra-aortic balloon support for myocardial infarction with cardiogenic shock improve outcome?

Authors:  Mohamed Y Khashan; Michael R Pinsky
Journal:  Crit Care       Date:  2013-03-06       Impact factor: 9.097

View more
  1 in total

1.  Temporary mechanical circulatory support for refractory heart failure: the German Heart Center Berlin experience.

Authors:  Gaik Nersesian; Felix Hennig; Marcus Müller; Johanna Mulzer; Dmytro Tsyganenko; Christoph Starck; Tom Gromann; Volkmar Falk; Evgenij Potapov; Felix Schoenrath
Journal:  Ann Cardiothorac Surg       Date:  2019-01
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.