The carina as a useful radiographic landmark for positioning the intraaortic balloon pump.

Jin-Tae Kim1, Jeong-Rim Lee, Jae-Kwang Kim, Seung Zhoo Yoon, Yunseok Jeon, Jae-Hyon Bahk, Ki-Bong Kim, Chong-Sung Kim, Young-Jin Lim, Hee-Soo Kim, Seong-Deok Kim.   

Abstract

BACKGROUND: The aortic knob is thought to be the most useful radiographic landmark for the proper positioning of the intraaortic balloon pump (IABP) tip. However, this has not been studied formally. In this study we assessed whether the aortic knob is a reliable landmark for positioning the IABP and compared it with another potential landmark, the carina.
METHODS: We measured the distance from the top of the distal aortic arch (aortic knob) to the left subclavian artery (LSCA) on three-dimensional computed tomography angiography in 100 patients. The distance from the level of the LSCA origin to the level of the carina was also measured using three-dimensional computed tomography in 150 additional patients.
RESULTS: In 16% of the aortic knob study population, the LSCA to aortic knob distance was <0 cm or 0 cm. The median distance from the LSCA to the carina was 42 mm (range: 30-63 mm). In the carina study population, the origin of the LSCA was 35-55 mm above the carina in 95.3% of patients.
CONCLUSION: In 16% of patients, the IABP was too close to the LSCA origin when it was placed at the aortic knob, whereas positioning the IABP at 2 cm above the carina provided an adequate position for the IABP tip (1.5-3.5 cm distal to the origin of the LSCA) in 95.3% of patients. The carina may be a more reliable landmark for positioning the IABP than the aortic knob.

Entities:  

Mesh:

Year:  2007        PMID: 17717232     DOI: 10.1213/01.ane.0000278086.23266.35

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  6 in total

Review 1.  Radiology of cardiac devices and their complications.

Authors:  J Dipoce; A Bernheim; H Spindola-Franco
Journal:  Br J Radiol       Date:  2014-11-20       Impact factor: 3.039

2.  Radiology of Intra-Aortic Balloon Pump Catheters.

Authors:  Nicholas G Rhodes; Tucker F Johnson; James H Boyum; Ashish Khandelwal; Barrett D Howell; Adam T Froemming; Atta Behfar
Journal:  Radiol Cardiothorac Imaging       Date:  2022-04-14

Review 3.  Mechanical Circulatory Support for Acute Heart Failure Complicated by Cardiogenic Shock.

Authors:  Min Suk Choi; Hunbo Shim; Yang Hyun Cho
Journal:  Int J Heart Fail       Date:  2020-01-22

4.  A novel technique for intra-aortic balloon positioning in the intensive care unit.

Authors:  Vijish Venugopal
Journal:  J Extra Corpor Technol       Date:  2012-09

5.  Contemporary applications of intra-aortic balloon counterpulsation for cardiogenic shock: a "real world" experience.

Authors:  Federico Pappalardo; Silvia Ajello; Massimiliano Greco; Małgorzata Celińska-Spodar; Michele De Bonis; Alberto Zangrillo; Andrea Montisci
Journal:  J Thorac Dis       Date:  2018-04       Impact factor: 2.895

6.  Imaging of mechanical cardiac assist devices.

Authors:  Daniel Ginat; Howard Todd Massey; Shweta Bhatt; Vikram S Dogra
Journal:  J Clin Imaging Sci       Date:  2011-05-02
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.