Literature DB >> 21249662

Preoperative intra aortic balloon pumps in patients undergoing coronary artery bypass grafting.

Thomas Theologou1, Mohamad Bashir, Arvind Rengarajan, Omar Khan, Tom Spyt, David Richens, Mark Field.   

Abstract

BACKGROUND: The intra aortic balloon pump (IABP) is a mechanical assist device which improves cardiac function. The device has a well-established place in algorithms for managing low cardiac output following cardiac surgery. There is increasing evidence that certain cardiac surgery patients benefit from a period of preoperative augmentation with the intra aortic balloon pump.
OBJECTIVES: To determine the effect of the preoperative intra aortic balloon pump on mortality and morbidity in a number of different patients groups undergoing coronary artery bypass grafting. SEARCH STRATEGY: The Cochrane Central Register of Controlled Trials (CENTRAL) on The Cochrane Library (Issue 3, 2009), MEDLINE (2000 to August 2009), EMBASE (1998 to August 2009), BIOSIS previews (1969 to August 2009) and ISI Proceedings (1990 to August 2009) were searched. References and ongoing registers of studies were checked. No language restrictions were applied. SELECTION CRITERIA: Randomised controlled trials (RCTs) of any size or length were included. DATA COLLECTION AND ANALYSIS: Papers were assessed for inclusion by two authors independently and differences were settled by consensus with a third author. Date are presented in the form of odds ratios (OR) and 95% confidence intervals (CI). MAIN
RESULTS: Six trials were included (five on-pump and one off-pump). This update adds the results of one further trial. Data from a total of 255 patients were included in the meta-analysis of mortality outcomes; all on-pump. Generally, the patients were considered as "high risk" and 132 were treated preoperatively with IABP and 123 served as controls. There were four hospital deaths in the intervention arm and 23 in the non-intervention arm (OR 0.18, 95% CI 0.08 to 0.41; P<0.0001). In a subgroup analysis, low cardiac index (<2.0 L/min/m(2)) was noted in 21 out of 105 patients in the treatment arm and 59 patients out of 88 in the non-treatment arm (OR 0.14, 95% CI: 0.08 to 0.25; P<0.00001). An off-pump versus on-pump analysis was not possible due to the limited number of off-pump studies. However a single well-conducted RCT suggested favourable effect of the preoperative IABP in off-pump patients. AUTHORS'
CONCLUSIONS: Evidence suggests that preoperative IABP may have a beneficial effect on mortality and morbidity in specific high risk patient groups undergoing coronary artery bypass grafting, however there are many problems with the quality, validity and generalisability of the trials. However, the available evidence is not robust enough to extend the use of IABP to truly elective, high risk patients. Defining more precisely which patient groups may benefit would be the challenge for the future.

Entities:  

Mesh:

Year:  2011        PMID: 21249662      PMCID: PMC8094869          DOI: 10.1002/14651858.CD004472.pub3

Source DB:  PubMed          Journal:  Cochrane Database Syst Rev        ISSN: 1361-6137


  36 in total

1.  The role of intra-aortic counterpulsation in high-risk OPCAB surgery: a prospective randomized study.

Authors:  Jan T Christenson; Marc Licker; Afksendiyos Kalangos
Journal:  J Card Surg       Date:  2003 Jul-Aug       Impact factor: 1.620

2.  Usefulness of preoperative intraaortic balloon pump therapy during off-pump coronary artery bypass grafting in high-risk patients.

Authors:  Tomoaki Suzuki; Manabu Okabe; Mitsuteru Handa; Fuyuhiko Yasuda; Yoichiro Miyake
Journal:  Ann Thorac Surg       Date:  2004-06       Impact factor: 4.330

3.  Aggressive preoperative use of intraaortic balloon pump in elderly patients undergoing coronary artery bypass grafting.

Authors:  D E Gutfinger; R A Ott; M Miller; A Selvan; M A Codini; H Alimadadian; T M Tanner
Journal:  Ann Thorac Surg       Date:  1999-03       Impact factor: 4.330

4.  Intraaortic balloon pump therapy facilitates posterior vessel off-pump coronary artery bypass grafting in high-risk patients.

Authors:  K B Kim; C Lim; H Ahn; J K Yang
Journal:  Ann Thorac Surg       Date:  2001-06       Impact factor: 4.330

5.  Pre-operative balloon counterpulsation and off-pump coronary surgery for high-risk patients.

Authors:  G Babatasi; M Massetti; P G Bruno; M Hamon; O Le Page; R Morello; A Khayat
Journal:  Cardiovasc Surg       Date:  2003-04

Review 6.  Preoperative intra-aortic balloon pump in patients undergoing coronary bypass surgery: a systematic review and meta-analysis.

Authors:  Adel M Dyub; Richard P Whitlock; Labib L Abouzahr; Claudio S Cinà
Journal:  J Card Surg       Date:  2008 Jan-Feb       Impact factor: 1.620

7.  A method of uniform stratification of risk for evaluating the results of surgery in acquired adult heart disease.

Authors:  V Parsonnet; D Dean; A D Bernstein
Journal:  Circulation       Date:  1989-06       Impact factor: 29.690

8.  Prophylactic intra-aortic balloon pump in high-risk patients undergoing coronary artery bypass grafting: a propensity score analysis.

Authors:  Antonio Miceli; Brenno Fiorani; Tommaso Hinna Danesi; Giovanni Melina; Riccardo Sinatra
Journal:  Interact Cardiovasc Thorac Surg       Date:  2009-04-09

9.  EuroSCORE: useful in directing preoperative intra-aortic balloon pump placement in cardiac surgery?

Authors:  David G Healy; Devendran Veerasingam; Alfred E Wood
Journal:  Heart Surg Forum       Date:  2006       Impact factor: 0.676

10.  Preoperative intraaortic balloon pumping improves outcomes for high-risk patients in routine coronary artery bypass graft surgery.

Authors:  Giuseppe Santarpino; Francesco Onorati; Antonino S Rubino; Karim Abdalla; Santo Caroleo; Ermenegildo Santangelo; Attilio Renzulli
Journal:  Ann Thorac Surg       Date:  2009-02       Impact factor: 4.330

View more
  15 in total

1.  Prophylactic intraaortic balloon counterpulsation in high-risk cardiac surgery: a survey of opinion and current practice.

Authors:  E Litton; A Delaney
Journal:  HSR Proc Intensive Care Cardiovasc Anesth       Date:  2013

2.  Contemporary applications of intra-aortic balloon counterpulsation for cardiogenic shock: a "real world" experience.

Authors:  Federico Pappalardo; Silvia Ajello; Massimiliano Greco; Małgorzata Celińska-Spodar; Michele De Bonis; Alberto Zangrillo; Andrea Montisci
Journal:  J Thorac Dis       Date:  2018-04       Impact factor: 2.895

3.  Preoperative IABP in high risk patients undergoing CABG.

Authors:  T Theologou; M L Field
Journal:  HSR Proc Intensive Care Cardiovasc Anesth       Date:  2011

Review 4.  Intra-aortic balloon pump counterpulsation (IABP) for myocardial infarction complicated by cardiogenic shock.

Authors:  Susanne Unverzagt; Michael Buerke; Antoinette de Waha; Johannes Haerting; Diana Pietzner; Melchior Seyfarth; Holger Thiele; Karl Werdan; Uwe Zeymer; Roland Prondzinsky
Journal:  Cochrane Database Syst Rev       Date:  2015-03-27

5.  Analysis of clinical outcomes of intra-aortic balloon pump during coronary artery bypass surgery.

Authors:  Gunduz Yumun; Ufuk Aydin; Yusuf Ata; Faruk Toktaş; Arda Aybars Pala; Ahmet Fatih Ozyazicioglu; Tamer Turk; Senol Yavuz
Journal:  Cardiovasc J Afr       Date:  2015 May-Jun       Impact factor: 1.167

6.  Analysis of clinical outcomes of intra-aortic balloon pump use during coronary artery bypass surgery.

Authors:  Gunduz Yumun; Ufuk Aydin; Yusuf Ata; Faruk Toktaş; Arda Aybars Pala; Ahmet Fatih Ozyazicioglu; Tamer Turk; Senol Yavuz
Journal:  Cardiovasc J Afr       Date:  2015 Jul-Aug       Impact factor: 1.167

7.  Temporal Trends of In-Hospital Mortality in Patients Treated with Intra-Aortic Balloon Pumping: A Nationwide Population Study in Taiwan, 1998-2008.

Authors:  Chung-Han Ho; Zhih-Cherng Chen; Chin-Chen Chu; Jhi-Joung Wang; Chun-Yen Chiang
Journal:  PLoS One       Date:  2015-06-26       Impact factor: 3.240

Review 8.  Evaluating outcomes used in cardiothoracic surgery interventional research: a systematic review of reviews to develop a core outcome set.

Authors:  Carina Benstoem; Ajay Moza; Rüdiger Autschbach; Christian Stoppe; Andreas Goetzenich
Journal:  PLoS One       Date:  2015-04-01       Impact factor: 3.240

9.  Preventive use of intra-aortic balloon pump in patients undergoing high-risk coronary artery bypass grafting: a retrospective study.

Authors:  Jingchao Zhang; Yan Lang; Longhui Guo; Xiaodong Song; Liliang Shu; Gang Su; Hai Liu; Jing Xu
Journal:  Med Sci Monit       Date:  2015-03-23

10.  Technological advancements in the care of the trauma patient.

Authors:  J J Siracuse; N N Saillant; C J Hauser
Journal:  Eur J Trauma Emerg Surg       Date:  2011-11-09       Impact factor: 3.693

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.