| Literature DB >> 29785300 |
Almutez M Gharaibeh1,2, Asier Villanueva3, David Mas3, Julian Espinosa3, Jorge L Alió2,4.
Abstract
PURPOSE: To assess anterior corneal surface stability 12 months following hyperopic LASIK correction with a light propagation algorithm.Entities:
Year: 2018 PMID: 29785300 PMCID: PMC5896223 DOI: 10.1155/2018/3060939
Source DB: PubMed Journal: J Ophthalmol ISSN: 2090-004X Impact factor: 1.909
Figure 1Axial visual quality versus corneal power. The peak is taken as the OCP.
Figure 2Simulation of rays inside the eye.
Preoperative and postoperative visual, refractive, and objective outcomes 12 months after hyperopic LASIKa,b,c.
| Pre | 3 months | 12 months |
|
|
|
| |
|---|---|---|---|---|---|---|---|
| Patients | 37 | ||||||
| Age | 35.35 ± 9.23 (18 to 51) | ||||||
| UDVA (logMAR) | 0.29 ± 0.31 (−0.08 to 1.30) | 0.06 ± 0.08 (0.00 to 0.40) | 0.03 ± 0.06 (0.00 to 0.22) | <0.01 | <0.01 | <0.01 | 1.0 |
| CDVA (logMAR) | 0.02 ± 0.03 (−0.08 to 0.15) | 0.02 ± 0.04 (0.00 to 0.15) | 0.02 ± 0.05 (0.00 to 0.22) | 0.50 | 1.0 | 0.85 | 1.0 |
| SPH (D) | 4.46 ± 1.47 (1.75 to 8.50) | 0.45 ± 0.99 (−1.25 to 3.50) | 0.55 ± 0.93 (−1.00 to 3.00) | <0.01 | <0.01 | <0.01 | 1.0 |
| CYL (D) | −1.57 ± 1.27 (−4.75 to 0.00) | −0.60 ± 0.42 (−2.00 to 0.00) | −0.55 ± 0.35 (−1.50 to 0.00) | <0.01 | 0.01 | <0.01 | 1.0 |
| SE (D) | 3.66 ± 1.44 (0.63 to 8.00) | 0.15 ± 0.99 (−1.38 to 3.00) | 0.29 ± 0.94 (−1.00 to 3.25) | <0.01 | <0.01 | <0.01 | 0.83 |
| OCP r3 (D) | 43.09 ± 1.48 (40.64 to 47.91) | 46.63 ± 1.68 (43.63 to 50.91) | 46.24 ± 1.94 (41.61 to 50.68) | <0.01 | <0.01 | <0.01 | 0.09 |
| OCP r4.5 (D) | 43.14 ± 1.48 (40.74 to 48.01) | 46.59 ± 1.70 (43.46 to 50.90) | 46.16 ± 1.92 (41.60 to 50.68) | <0.01 | <0.01 | <0.01 | 0.06 |
UDVA = uncorrected distance visual acuity; CDVA = corrected distance visual acuity; SPH = sphere; CYL = cylinder; SE = spherical equivalent; OCP r3 = objective corneal power radius 3 mm; OCP r4.5 = objective corneal power radius 4.5 mm. aValues shown as mean ± standard deviation (range). bANOVA for paired data. cPost hoc with Bonferroni correction.
Preoperative and postoperative visual, refractive, and objective outcomes 12 months after hyperopic LASIKa,b,c (group 1, SE ≤ 3).
| Pre | 3 months | 12 months |
|
|
|
| |
|---|---|---|---|---|---|---|---|
| Eyes ( | 9 | ||||||
| Age | 37.56 ± 7.41 (27 to 45) | ||||||
| UDVA (logMAR) | 0.29 ± 0.28 (0.00 to 0.82) | 0.04 ± 0.05 (0.00 to 0.15) | 0.03 ± 0.07 (0.00 to 0.22) | <0.01 | <0.01 | <0.01 | 0.40 |
| CDVA (logMAR) | 0.01 ± 0.02 (0.00 to 0.07) | 0.01 ± 0.02 (0.00 to 0.05) | 0.02 ± 0.07 (0.00 to 0.22) | 1.0 | 1.0 | 1.0 | 1.0 |
| SPH (D) | 3.03 ± 0.88 (1.75 to 4.50) | 0.25 ± 0.31 (−0.25 to 0.75) | 0.33 ± 0.48 (0.00 to 1.50) | <0.01 | <0.01 | <0.01 | 0.69 |
| CYL (D) | −2.31 ± 1.45 (−4.75 to −0.50) | −0.53 ± 0.29 (−1.00 to −0.25) | −0.50 ± 0.27 (−1.00 to −0.25) | <0.01 | 0.02 | 0.01 | 1.0 |
| SE (D) | 1.88 ± 0.73 (0.63 to 2.88) | 0.01 ± 0.43 (−0.50 to 0.63) | 0.08 ± 0.40 (−0.25 to 1.13) | <0.01 | <0.01 | <0.01 | 0.53 |
| OCP r3 (D) | 43.33 ± 1.08 (41.91 to 44.67) | 45.67 ± 1.42 (43.63 to 47.52) | 45.42 ± 1.45 (43.21 to 47.63) | <0.01 | <0.01 | <0.01 | 0.30 |
| OCP r4.5 (D) | 43.41 ± 1.07 (42.01 to 44.76) | 45.61 ± 1.37 (43.53 to 47.57) | 45.35 ± 1.46 (43.01 to 47.52) | <0.01 | <0.01 | <0.01 | 0.36 |
UDVA = uncorrected distance visual acuity; CDVA = corrected distance visual acuity; SPH = sphere; CYL = cylinder; SE = spherical equivalent; OCP r3 = objective corneal power radius 3 mm; OCP r4.5 = objective corneal power radius 4.5 mm. aValues shown as mean ± standard deviation (range). bFriedman test. cWilcoxon test with Bonferroni correction (p < 0.017).
Preoperative and postoperative visual, refractive and objective outcomes 12 months after hyperopic LASIKa,b,c (group 2, SE > 3).
| Pre | 3 months | 12 months |
|
|
|
| |
|---|---|---|---|---|---|---|---|
| Eyes ( | 28 | ||||||
| Age | 34.64 ± 9.75 (18 to 51) | ||||||
| UDVA (logMAR) | 0.30 ± 0.33 (−0.08 to 1.30) | 0.06 ± 0.09 (0.00 to 0.40) | 0.03 ± 0.05 (0.00 to 0.15) | <0.01 | <0.01 | <0.01 | 0.31 |
| CDVA (logMAR) | 0.01 ± 0.04 (−0.08 to 0.15) | 0.02 ± 0.05 (0.00 to 0.15) | 0.02 ± 0.04 (0.00 to 0.14) | 0.66 | 1.0 | 1.0 | 1.0 |
| SPH (D) | 4.88 ± 1.35 (3.50 to 8.50) | 0.51 ± 1.13 (−1.25 to 3.50) | 0.62 ± 1.03 (−1.00 to 3.00) | <0.01 | <0.01 | <0.01 | 1.0 |
| CYL (D) | −1.33 ± 1.13 (−4.25 to 0.00) | −0.61 ± 0.41 (−2.00 to 0.00) | −0.57 ± 0.38 (−1.50 to 0.00) | <0.01 | 0.02 | <0.01 | 1.0 |
| SE (D) | 4.22 ± 1.12 (2.75 to 8.00) | 0.21 ± 1.13 (−1.38 to 3.00) | 0.35 ± 1.06 (−1.00 to 3.25) | <0.01 | <0.01 | <0.01 | 1.0 |
| OCP r3 (D) | 43.01 ± 1.60 (40.64 to 47.91) | 46.94 ± 1.66 (44.46 to 50.91) | 46.50 ± 2.02 (41.61 to 50.68) | <0.01 | <0.01 | <0.01 | 0.17 |
| OCP r4.5 (D) | 43.05 ± 1.60 (40.74 to 48.01) | 46.91 ± 1.70 (44.27 to 50.90) | 46.44 ± 2.00 (41.60 to 50.68) | <0.01 | <0.01 | <0.01 | 0.13 |
UDVA = uncorrected distance visual acuity; CDVA = corrected distance visual acuity; SPH = sphere; CYL = cylinder; SE = spherical equivalent; OCP r3 = objective corneal power radius 3 mm; OCP r4.5 = objective corneal power radius 4.5 mm. aValues shown as mean ± standard deviation (range). bANOVA for paired data. cPost hoc with Bonferroni correction.
Figure 3Clinical outcomes. Postoperative follow-up results (12 months after surgery). (a) Postoperative uncorrected visual acuity compared with the preoperative corrected distance visual acuity (CDVA). (b) Changes in lines of CDVA. (c) Intended versus achieved correction (manifest refraction). (d) Distribution of postoperative spherical equivalent (predictability). (e) Distribution of preoperative and postoperative astigmatism. (f) Stability of the manifest refraction.
Figure 4OCP stability.