Literature DB >> 18500082

Pseudoaccommodation and visual acuity with Technovision presbyLASIK and a theoretical simulated Array multifocal intraocular lens.

Carlos Illueca1, Jorge L Alió, David Mas, Dolores Ortiz, Jorge Pérez, J Espinosa, Sala Esperanza.   

Abstract

PURPOSE: To compare the visual results of presbyLASIK patients to the best theoretical pseudoaccommodation that could be achieved using a multifocal refractive intraocular lens (IOL) model based on the optical structure of a simulated AMO Array multifocal IOL.
METHODS: The study included 10 hyperopic eyes that underwent central presbyLASIK surgery using a Technovision excimer laser platform. Mean patient age was 57 years, and mean preoperative spherical equivalent refraction was 1.28+/-0.87 diopters. The optical quality was evaluated by objective distance and near decimal visual acuities calculated using a Fresnel propagation algorithm based on a realistic eye model. Results of the presbyLASIK technique were compared with the theoretical results obtained for the same eye with an ideal, best-fit multifocal IOL (simulated Array multifocal IOL) substituted for the crystalline lens.
RESULTS: For near objective visual acuity (from 25 cm to 1 m), the ideal, theoretical Array-like lens provided values of visual acuity above 0.5 for all object distances, whereas presbyLASIK also provided good visual responses for distances beyond 45 cm. For distance vision (from 1.5 to 6 m), both the IOL and presbyLASIK visual acuities were over 0.5, but the optical performance of the ideal Array-like lens was slightly worse than with presbyLASIK.
CONCLUSIONS: Overall near to distance visual acuity obtained with the presbyLASIK technique is comparable to the best visual acuity that could be achieved with a simulated Array multifocal IOL. Near visual acuity with presbyLASIK falls off from the ideal.

Entities:  

Mesh:

Year:  2008        PMID: 18500082     DOI: 10.3928/1081597X-20080401-05

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  5 in total

1.  A new method of cornea modulation with excimer laser for simultaneous correction of presbyopia and ametropia.

Authors:  Detlef Uthoff; Markus Pölzl; Daniel Hepper; Detlef Holland
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-02-22       Impact factor: 3.117

Review 2.  [Accommodation and presbyopia : part 2: surgical procedures for the correction of presbyopia].

Authors:  M Baumeister; T Kohnen
Journal:  Ophthalmologe       Date:  2008-11       Impact factor: 1.059

3.  Corneal Stability following Hyperopic LASIK with Advanced Laser Ablation Profiles Analyzed by a Light Propagation Study.

Authors:  Almutez M Gharaibeh; Asier Villanueva; David Mas; Julian Espinosa; Jorge L Alió
Journal:  J Ophthalmol       Date:  2018-03-28       Impact factor: 1.909

Review 4.  Presbyopic correction on the cornea.

Authors:  Samuel Arba Mosquera; Jorge L Alió
Journal:  Eye Vis (Lond)       Date:  2014-11-13

5.  Long-term visual outcomes after Crystalens(®) HD intraocular lens implantation.

Authors:  Alexandra E Karavitaki; Ioannis G Pallikaris; Sophia I Panagopoulou; George A Kounis; George Kontadakis; George D Kymionis
Journal:  Clin Ophthalmol       Date:  2014-05-22
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.