Literature DB >> 16126767

Evaluation of particulate filtering respirators using inward leakage (IL) or total inward leakage (TIL) testing--Korean experience.

Don-Hee Han1, Jinheon Lee.   

Abstract

Korean certification regulation for particulate filtering respirators requires inward leakage (IL) or total inward leakage (TIL) testing according to European Standard EN 13274-1, and the standard levels of compliance are similar to those of the European Standard. This study was conducted to evaluate particulate filtering respirators being commercially used in the Korean market using an IL or TIL test and the validity of standard level in Korea. Three half masks and 10 filtering facepieces (two top class, four 1st class and four 2nd class)-a total of 13 brand name respirators-were selected for the test with panels of 10 subjects. Each subject was classified with nine facial dimension grid squares in accordance with face length and lip length. IL or TIL testing was conducted at the laboratory of the 3M Innovation Center in which the experimental instruments and systems were established in compliance with European standards. The testing procedure followed EN 13274-1 (2001). As expected, leakages of half masks were less than those of filtering facepieces and the latter were significantly different among brands. TILs of the 1st class filtering facepieces were found to be much more than those of the 2nd class and the result may cause a wearer to get confused when selecting a mask. The main route leakage for filtering facepieces may not be the filter medium but the face seal. Therefore, it is necessary to develop well-fitting filtering facepieces for Koreans. Because leakages were significantly different for different facial dimensions, a defined test panel for IL or TIL testing according to country or race should be developed. A more precise method to demonstrate fit, for example, fit testing such as in the US regulations, will be needed before IL or TIL testing or when selecting a respirator. Another finding implies that geometric mean of five exercises for IL or TIL may be better than arithmetic mean to establish a standard individual subject mean.

Entities:  

Mesh:

Year:  2005        PMID: 16126767     DOI: 10.1093/annhyg/mei034

Source DB:  PubMed          Journal:  Ann Occup Hyg        ISSN: 0003-4878


  7 in total

1.  Correlation of respirator fit measured on human subjects and a static advanced headform.

Authors:  Michael S Bergman; Xinjian He; Michael E Joseph; Ziqing Zhuang; Brian K Heimbuch; Ronald E Shaffer; Melanie Choe; Joseph D Wander
Journal:  J Occup Environ Hyg       Date:  2015       Impact factor: 2.155

2.  Respirator Performance against Nanoparticles under Simulated Workplace Activities.

Authors:  Evanly Vo; Ziqing Zhuang; Matthew Horvatin; Yuewei Liu; Xinjian He; Samy Rengasamy
Journal:  Ann Occup Hyg       Date:  2015-07-15

3.  A comparison of total inward leakage measured using sodium chloride (NaCl) and corn oil aerosol methods for air-purifying respirators.

Authors:  Samy Rengasamy; Ziqing Zhuang; George Niezgoda; Gary Walbert; Robert Lawrence; Brenda Boutin; Judith Hudnall; William P Monaghan; Michael Bergman; Colleen Miller; James Harris; Christopher Coffey
Journal:  J Occup Environ Hyg       Date:  2018-08       Impact factor: 2.155

4.  Development of an advanced respirator fit-test headform.

Authors:  Michael S Bergman; Ziqing Zhuang; David Hanson; Brian K Heimbuch; Michael J McDonald; Andrew J Palmiero; Ronald E Shaffer; Delbert Harnish; Michael Husband; Joseph D Wander
Journal:  J Occup Environ Hyg       Date:  2014       Impact factor: 2.155

5.  Effects of breathing frequency and flow rate on the total inward leakage of an elastomeric half-mask donned on an advanced manikin headform.

Authors:  Xinjian He; Sergey A Grinshpun; Tiina Reponen; Roy McKay; Michael S Bergman; Ziqing Zhuang
Journal:  Ann Occup Hyg       Date:  2013-10-08

6.  A quantitative assessment of the total inward leakage of NaCl aerosol representing submicron-size bioaerosol through N95 filtering facepiece respirators and surgical masks.

Authors:  Samy Rengasamy; Benjamin C Eimer; Jonathan Szalajda
Journal:  J Occup Environ Hyg       Date:  2014       Impact factor: 2.155

7.  Fitting characteristics of N95 filtering-facepiece respirators used widely in China.

Authors:  Yanyan Yu; Luman Jiang; Ziqing Zhuang; Yuewei Liu; Xinyan Wang; Juyuan Liu; Mingna Yang; Weihong Chen
Journal:  PLoS One       Date:  2014-01-21       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.