Literature DB >> 29704127

Correlation between femoral offset loss and dynamic hip screw cut-out complications after pertrochanteric fractures: a case-control study.

Baptiste Boukebous1, Pascal Guillon2, Eric Vandenbussche3, Marc Antoine Rousseau4.   

Abstract

BACKGROUND: Screw-plates disassembly incidence after pertrochanteric fracture (PF) amounts to 1 and 16% among the elderly population. The main occurrence is early cervical screw cut-out. The population at highest risk of disassembly remains difficult to identify. The correlation between femoral offset loss and disassembly occurrence has never been surveyed.
OBJECTIVES: A radiological prognosis score for screw plate disassembly was defined to reflect trochanteric impaction (TI); it was based on a femoral offset ratio. STUDY DESIGN AND METHODS: Our single-centre retrospective case-control study surveyed patients suffering from Dynamic Hip Screw (DHS, Synthes®) disassembly following osteosynthesis of non-pathological osteoporotic PF between 2004 and 2014. All cases were categorised by age and gender and paired to three patients in the control group. The primary endpoint was TI measurement, corresponding to offset loss on the operated hip compared to healthy hip offset and expressed as a percentage. The measurement was done on an immediate postoperative X-ray. The secondary endpoints were tip apex distance (TAD) measurement, Ender and AO classifications, as well as postoperative weight-bearing prescription.
RESULTS: Twenty-three cases and 69 controls were surveyed. The case group's average age was 87; 70% of the cases were women. The main disassembly occurrence delay was after 27 days. Average TI was 26% within the patients global group and 12% within the control group (p < 10-5). Over a 21% impaction percentage, disassembly occurrence represents a greater risk: OR = 21.95% CI [5.4-104.3], p < 10-5. Ender 3 type fractures were the most frequent indication for surgery within the case group. Average TAD was 20 mm within the case group, and 17 mm within the control group (p = 0.03). The weight-bearing prescription rate was 52% within the control group and 21% within the case group (p = 0.014). 14.5% of the control group had a TI > 21%.
CONCLUSIONS: Using the offset ratio tool, TI measurement was associated with a greater risk of DHS disassembly when it was higher than 21%. The exclusive use of a DHS device does not seem optimal for a TI > 21%. Weight-bearing may be prescribed for all the patients with a TI < 21%, provided good implant positioning is secured.

Entities:  

Keywords:  Cut-out; DHS; Disassembly; Dynamic hip screws; Femoral offset; Pertrochanteric fractures; Plates; TAD; Tip Apex distance; Weight-bearing

Mesh:

Year:  2018        PMID: 29704127     DOI: 10.1007/s00590-018-2204-0

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  23 in total

1.  [Osteosynthesis of lesions of the proximal femur using dynamic screw plates. Multicenter study: 1871 cases].

Authors:  P Putz; E Coussaert; D Delvaux; P Long Pretz; R Thys; F Cantraine
Journal:  Int Orthop       Date:  1990       Impact factor: 3.075

2.  Sliding hip screws: modes of failure.

Authors:  A H Simpson; K Varty; C A Dodd
Journal:  Injury       Date:  1989-07       Impact factor: 2.586

3.  Loss of offset after pertrochanteric hip fractures affects hip function one year after surgery with a short intramedullary nail. A prospective cohort study.

Authors:  Max Gordon; Per-Olov Berntsson; Erik Sjölund; Yilmaz Demir; Carl Johan Hedbeck; André Stark; Olof Sköldenberg
Journal:  Int Orthop       Date:  2015-06-24       Impact factor: 3.075

4.  The effect of local bone density on mechanical failure after internal fixation of pertrochanteric fractures.

Authors:  Changhua Li; Bingju Xie; Shanxi Chen; Guangmao Lin; Guojing Yang; Lei Zhang
Journal:  Arch Orthop Trauma Surg       Date:  2015-12-01       Impact factor: 3.067

5.  The Gotfried PerCutaneous Compression Plate versus the Dynamic Hip Screw in the treatment of pertrochanteric hip fractures: minimal invasive treatment reduces operative time and postoperative pain.

Authors:  Heinrich M J Janzing; Bert J J Houben; Sven E Brandt; Vuthy Chhoeurn; Samuel Lefever; Paul Broos; Peter Reynders; Paul Vanderschot
Journal:  J Trauma       Date:  2002-02

6.  DHS osteosynthesis for stable pertrochanteric femur fractures with a two-hole side plate.

Authors:  Michiel H J Verhofstad; Chris van der Werken
Journal:  Injury       Date:  2004-10       Impact factor: 2.586

7.  [Fracture of the great trochanter treated by dynamic hip screw plate: measure of impaction according to fracture type].

Authors:  P Oger; V Katz; N Lecorre; P Beaufils
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  1998-10

8.  Risk factors in cutout of sliding hip screw in intertrochanteric fractures: an evaluation of 937 patients.

Authors:  Kuang-Kai Hsueh; Chi-Kuang Fang; Chuan-Mu Chen; Yu-Ping Su; Heng-Fei Wu; Fang-Yao Chiu
Journal:  Int Orthop       Date:  2009-09-26       Impact factor: 3.075

9.  Healing complications after internal fixation of trochanteric hip fractures: the prognostic value of osteoporosis.

Authors:  C Barrios; L A Broström; A Stark; G Walheim
Journal:  J Orthop Trauma       Date:  1993       Impact factor: 2.512

10.  The influence of hip rotation on femoral offset in plain radiographs.

Authors:  Philipp Lechler; Michael Frink; Aashish Gulati; David Murray; Tobias Renkawitz; Benjamin Bücking; Steffen Ruchholtz; Christoph Kolja Boese
Journal:  Acta Orthop       Date:  2014-06-23       Impact factor: 3.717

View more
  1 in total

1.  No difference between lag screw and helical blade for cephalomedullary nail cut-out a systematic review and meta-analysis.

Authors:  Mitchell Ng; Nihar S Shah; Ivan Golub; Matthew Ciminero; Kevin Zhai; Kevin K Kang; Ahmed K Emara; Nicolas S Piuzzi
Journal:  Eur J Orthop Surg Traumatol       Date:  2021-10-19
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.