Literature DB >> 9846328

[Fracture of the great trochanter treated by dynamic hip screw plate: measure of impaction according to fracture type].

P Oger1, V Katz, N Lecorre, P Beaufils.   

Abstract

INTRODUCTION: The sliding plate has appeared to be a reliable answer for trochanteric fractures. However, impaction allowed by the material may, have an adverse effect (medialisation, shortening, jutting out of the lag screw). The aim of our study was to measure the sliding of the screw in order to assess the impaction in various types of fracture, according to the Ender classification.
MATERIAL AND METHODS: Hundred trochanteric fractures have been treated between 1991 and 1993. Eighty four have been analyzed with a follow-up of three months after surgery. The average age was 80.1 years with a 4.2 sex ratio (16 males). One hundred and thirty five degrees free sliding plates were employed for fracture fixation. Full weight bearing was allowed in 78.6 per cent of patients. According to Ender classification, 35 per cent of fractures were type 1, 4 or 5. This was the first group. The second group consisted of types 2 and 3 and the third group of types 6, 7 and 8. The results were assessed on AP and lateral X-rays. The ratio between screw thread length (constant) and screw outside the barrel length, was used to measure impaction on AP view. Osteoporosis was evaluated according to Singh.
RESULTS: Despite two screw protrusions out of the femoral head and two failures of the plate, we have observed a healing rate of 100 per cent after three months. Sliding averaged 6.2 mm in group 1, 10.5 mm in group 2 and 16.4 mm in groupe 3. Weight bearing had a low influence on the amount of sliding. DISCUSSION: Group 1 consists of fractures (types 1, 4 and 5) which are two parts fractures considered as stable. Group 2 corresponds to types 2 and 3 considered as intermediate fractures with relative stability. In group 3 (types 6, 7 and 8) we have observed major fracture instability. Osteoporosis does not seem to be the major factor regarding screw sliding.
CONCLUSION: The sliding plate is reliable. However, complex fractures healed in a wrong position which is definitely not acceptable, especially for young patients. Therefore, we advise to avoid the use of sliding plate in case of Ender type 6, 7 and 8.

Entities:  

Mesh:

Year:  1998        PMID: 9846328

Source DB:  PubMed          Journal:  Rev Chir Orthop Reparatrice Appar Mot        ISSN: 0035-1040


  2 in total

1.  Correlation between femoral offset loss and dynamic hip screw cut-out complications after pertrochanteric fractures: a case-control study.

Authors:  Baptiste Boukebous; Pascal Guillon; Eric Vandenbussche; Marc Antoine Rousseau
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-04-27

2.  The Influence of Static Load and Sideways Impact Fall on Extramedullary Bone Plates Used to Treat Intertrochanteric Femoral Fracture: A Preclinical Strength Assessment.

Authors:  Pratik Nag; Bhaskar Borgohain; Kashif Akhtar Ahmed; Pranjal Phukan; Neeraj Kumar; Alireza Borjali; Kartik Mangudi Varadarajan; Souptick Chanda
Journal:  Ann Biomed Eng       Date:  2022-07-12       Impact factor: 4.219

  2 in total