Literature DB >> 29691781

Characterization of Harmonic Signal Acquisition with Parallel Dipole and Multipole Detectors.

Sung-Gun Park1, Gordon A Anderson2, James E Bruce3.   

Abstract

Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) is a powerful instrument for the study of complex biological samples due to its high resolution and mass measurement accuracy. However, the relatively long signal acquisition periods needed to achieve high resolution can serve to limit applications of FTICR-MS. The use of multiple pairs of detector electrodes enables detection of harmonic frequencies present at integer multiples of the fundamental cyclotron frequency, and the obtained resolving power for a given acquisition period increases linearly with the order of harmonic signal. However, harmonic signal detection also increases spectral complexity and presents challenges for interpretation. In the present work, ICR cells with independent dipole and harmonic detection electrodes and preamplifiers are demonstrated. A benefit of this approach is the ability to independently acquire fundamental and multiple harmonic signals in parallel using the same ions under identical conditions, enabling direct comparison of achieved performance as parameters are varied. Spectra from harmonic signals showed generally higher resolving power than spectra acquired with fundamental signals and equal signal duration. In addition, the maximum observed signal to noise (S/N) ratio from harmonic signals exceeded that of fundamental signals by 50 to 100%. Finally, parallel detection of fundamental and harmonic signals enables deconvolution of overlapping harmonic signals since observed fundamental frequencies can be used to unambiguously calculate all possible harmonic frequencies. Thus, the present application of parallel fundamental and harmonic signal acquisition offers a general approach to improve utilization of harmonic signals to yield high-resolution spectra with decreased acquisition time. Graphical Abstract ᅟ.

Entities:  

Keywords:  Harmonic frequencies; High resolution; Parallel acquisition; Scan rate

Year:  2018        PMID: 29691781      PMCID: PMC6537869          DOI: 10.1007/s13361-018-1954-6

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  13 in total

Review 1.  Quantitative mass spectrometry in proteomics: critical review update from 2007 to the present.

Authors:  Marcus Bantscheff; Simone Lemeer; Mikhail M Savitski; Bernhard Kuster
Journal:  Anal Bioanal Chem       Date:  2012-07-08       Impact factor: 4.142

2.  Fourier transform ion cyclotron resonance mass spectrometer with coaxial multi-electrode cell ('O-trap'): first experimental demonstration.

Authors:  A S Misharin; R A Zubarev; V M Doroshenko
Journal:  Rapid Commun Mass Spectrom       Date:  2010-07-30       Impact factor: 2.419

3.  Coaxial multi-electrode cell ('O-trap') for high-sensitivity detection at a multiple frequency in Fourier transform ion cyclotron resonance mass spectrometry: main design and modeling results.

Authors:  Alexander S Misharin; Roman A Zubarev
Journal:  Rapid Commun Mass Spectrom       Date:  2006       Impact factor: 2.419

Review 4.  Proteomics by mass spectrometry: approaches, advances, and applications.

Authors:  John R Yates; Cristian I Ruse; Aleksey Nakorchevsky
Journal:  Annu Rev Biomed Eng       Date:  2009       Impact factor: 9.590

Review 5.  Mass spectrometry: from proteomics to metabolomics and lipidomics.

Authors:  William J Griffiths; Yuqin Wang
Journal:  Chem Soc Rev       Date:  2009-02-04       Impact factor: 54.564

6.  21 Tesla Fourier Transform Ion Cyclotron Resonance Mass Spectrometer: A National Resource for Ultrahigh Resolution Mass Analysis.

Authors:  Christopher L Hendrickson; John P Quinn; Nathan K Kaiser; Donald F Smith; Greg T Blakney; Tong Chen; Alan G Marshall; Chad R Weisbrod; Steven C Beu
Journal:  J Am Soc Mass Spectrom       Date:  2015-06-20       Impact factor: 3.109

7.  21 Tesla Fourier Transform Ion Cyclotron Resonance Mass Spectrometer Greatly Expands Mass Spectrometry Toolbox.

Authors:  Jared B Shaw; Tzu-Yung Lin; Franklin E Leach; Aleksey V Tolmachev; Nikola Tolić; Errol W Robinson; David W Koppenaal; Ljiljana Paša-Tolić
Journal:  J Am Soc Mass Spectrom       Date:  2016-10-12       Impact factor: 3.109

8.  High-resolution Fourier transform ion cyclotron resonance mass spectrometry with increased throughput for biomolecular analysis.

Authors:  Konstantin O Nagornov; Mikhail V Gorshkov; Anton N Kozhinov; Yury O Tsybin
Journal:  Anal Chem       Date:  2014-09-03       Impact factor: 6.986

9.  Basics of mass spectrometry based metabolomics.

Authors:  Frédérique Courant; Jean-Philippe Antignac; Gaud Dervilly-Pinel; Bruno Le Bizec
Journal:  Proteomics       Date:  2014-09-25       Impact factor: 3.984

10.  Parallel Spectral Acquisition with an Ion Cyclotron Resonance Cell Array.

Authors:  Sung-Gun Park; Gordon A Anderson; Arti T Navare; James E Bruce
Journal:  Anal Chem       Date:  2015-12-24       Impact factor: 6.986

View more
  3 in total

1.  Parallel Detection of Fundamental and Sixth Harmonic Signals Using an ICR Cell with Dipole and Sixth Harmonic Detectors.

Authors:  Sung-Gun Park; Gordon A Anderson; James E Bruce
Journal:  J Am Soc Mass Spectrom       Date:  2020-01-30       Impact factor: 3.109

Review 2.  Applications and advancements of FT-ICR-MS for interactome studies.

Authors:  Juan D Chavez; Sung-Gun Park; Jared P Mohr; James E Bruce
Journal:  Mass Spectrom Rev       Date:  2020-12-08       Impact factor: 10.946

3.  Application of frequency multiple FT-ICR-MS signal acquisition for improved proteome research.

Authors:  Sung-Gun Park; Jared P Mohr; Gordon A Anderson; James E Bruce
Journal:  Int J Mass Spectrom       Date:  2021-03-19       Impact factor: 1.934

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.