High-resolution Fourier transform ion cyclotron resonance mass spectrometry with increased throughput for biomolecular analysis.

Konstantin O Nagornov1, Mikhail V Gorshkov, Anton N Kozhinov, Yury O Tsybin.   

Abstract

A multielectrode ion cyclotron resonance (ICR) cell, herein referred to as the "4X cell", for signal detection at the quadruple frequency multiple was implemented and characterized on a commercial 10 T Fourier transform ICR mass spectrometer (FT-ICR MS). Notably, with the 4X cell operating at a 10 T magnetic field we achieved a 4-fold increase in MS acquisition rate per unit of resolving power for signal detection periods typically employed in FTMS, viz., shorter than 6 s. Effectively, the obtained resolution performance represents the limit of the standard measurement principle with dipolar signal detection and FT signal processing at an equivalent magnetic field of 40 T. In other words, the achieved resolving powers are 4 times higher than those provided by 10 T FT-ICR MS with a standard ICR cell. For example, resolving powers of 170,000 and 70,000 were obtained in magnitude-mode Fourier spectra of 768 and 192 ms apodized transient signals acquired for a singly charged fluorinated phosphazine (m/z 1422) and a 19-fold charged myoglobin (MW 16.9 kDa), respectively. In peptide analysis, the baseline-resolved isotopic fine structures were obtained with as short as 768 ms transients. In intact protein analysis, the average resolving power of 340,000 across the baseline-resolved (13)C isotopic pattern of multiply charged ions of bovine serum albumin was obtained with 1.5 s transients. The dynamic range and the mass measurement accuracy of the 4X cell were found to be comparable to the ones obtained for the standard ICR cell on the same mass spectrometer. Overall, the reported results validate the advantages of signal detection at frequency multiples for increased throughput in FT-ICR MS, essential for numerous applications with time constraints, including proteomics.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25140615     DOI: 10.1021/ac501579h

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  18 in total

1.  Parallel detection in a single ICR cell: Spectral averaging and improved S/N without increased acquisition time.

Authors:  Sung-Gun Park; Gordon A Anderson; James E Bruce
Journal:  Int J Mass Spectrom       Date:  2017-09-08       Impact factor: 1.986

2.  Tracking the Magnetron Motion in FT-ICR Mass Spectrometry.

Authors:  Roland Jertz; Jochen Friedrich; Claudia Kriete; Evgeny N Nikolaev; Gökhan Baykut
Journal:  J Am Soc Mass Spectrom       Date:  2015-05-14       Impact factor: 3.109

3.  Ion trap with narrow aperture detection electrodes for Fourier transform ion cyclotron resonance mass spectrometry.

Authors:  Konstantin O Nagornov; Anton N Kozhinov; Oleg Y Tsybin; Yury O Tsybin
Journal:  J Am Soc Mass Spectrom       Date:  2015-03-14       Impact factor: 3.109

4.  21 Tesla Fourier Transform Ion Cyclotron Resonance Mass Spectrometer Greatly Expands Mass Spectrometry Toolbox.

Authors:  Jared B Shaw; Tzu-Yung Lin; Franklin E Leach; Aleksey V Tolmachev; Nikola Tolić; Errol W Robinson; David W Koppenaal; Ljiljana Paša-Tolić
Journal:  J Am Soc Mass Spectrom       Date:  2016-10-12       Impact factor: 3.109

5.  Correlating Resolving Power, Resolution, and Collision Cross Section: Unifying Cross-Platform Assessment of Separation Efficiency in Ion Mobility Spectrometry.

Authors:  James N Dodds; Jody C May; John A McLean
Journal:  Anal Chem       Date:  2017-10-30       Impact factor: 6.986

6.  Parallel Spectral Acquisition with Orthogonal ICR Cells.

Authors:  Sung-Gun Park; Gordon A Anderson; James E Bruce
Journal:  J Am Soc Mass Spectrom       Date:  2017-01-05       Impact factor: 3.109

7.  Surface Induced Dissociation Coupled with High Resolution Mass Spectrometry Unveils Heterogeneity of a 211 kDa Multicopper Oxidase Protein Complex.

Authors:  Mowei Zhou; Jing Yan; Christine A Romano; Bradley M Tebo; Vicki H Wysocki; Ljiljana Paša-Tolić
Journal:  J Am Soc Mass Spectrom       Date:  2018-01-31       Impact factor: 3.109

8.  Parallel Detection of Fundamental and Sixth Harmonic Signals Using an ICR Cell with Dipole and Sixth Harmonic Detectors.

Authors:  Sung-Gun Park; Gordon A Anderson; James E Bruce
Journal:  J Am Soc Mass Spectrom       Date:  2020-01-30       Impact factor: 3.109

9.  Characterization of Harmonic Signal Acquisition with Parallel Dipole and Multipole Detectors.

Authors:  Sung-Gun Park; Gordon A Anderson; James E Bruce
Journal:  J Am Soc Mass Spectrom       Date:  2018-04-24       Impact factor: 3.109

10.  Parallel Spectral Acquisition with an Ion Cyclotron Resonance Cell Array.

Authors:  Sung-Gun Park; Gordon A Anderson; Arti T Navare; James E Bruce
Journal:  Anal Chem       Date:  2015-12-24       Impact factor: 6.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.