Coaxial multi-electrode cell ('O-trap') for high-sensitivity detection at a multiple frequency in Fourier transform ion cyclotron resonance mass spectrometry: main design and modeling results.

Alexander S Misharin1, Roman A Zubarev.   

Abstract

Separation of the functions of ion excitation and detection between different cell compartments allows for implementation of excitation and detection techniques unattainable in a single compartment of the conventional ion cyclotron resonance (ICR) cell. In particular, multi-electrode detection at a multiple of the main cyclotron frequency can be utilized without the loss of sensitivity and other negative effects. The new O-trap designed exclusively for ion detection adds an additional, internal coaxial cylinder around which ions with excited cyclotron orbits rotate. Comparison of simulated performance characteristics of the new O-trap with those of the same-size conventional cylindrical cell shows that the O-trap can provide higher sensitivity and ion capacity. Multiplexing of the O-traps can further increase the analysis speed. Future efforts will be aimed at building and testing experimentally the coaxial O-trap, including optimization of the method of ion transfer between the compartments of the cell. Copyright (c) 2006 John Wiley & Sons, Ltd.

Mesh:

Year:  2006        PMID: 17019671     DOI: 10.1002/rcm.2724

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  6 in total

1.  Parallel detection in a single ICR cell: Spectral averaging and improved S/N without increased acquisition time.

Authors:  Sung-Gun Park; Gordon A Anderson; James E Bruce
Journal:  Int J Mass Spectrom       Date:  2017-09-08       Impact factor: 1.986

2.  Parallel Spectral Acquisition with Orthogonal ICR Cells.

Authors:  Sung-Gun Park; Gordon A Anderson; James E Bruce
Journal:  J Am Soc Mass Spectrom       Date:  2017-01-05       Impact factor: 3.109

3.  Parallel Detection of Fundamental and Sixth Harmonic Signals Using an ICR Cell with Dipole and Sixth Harmonic Detectors.

Authors:  Sung-Gun Park; Gordon A Anderson; James E Bruce
Journal:  J Am Soc Mass Spectrom       Date:  2020-01-30       Impact factor: 3.109

4.  Characterization of Harmonic Signal Acquisition with Parallel Dipole and Multipole Detectors.

Authors:  Sung-Gun Park; Gordon A Anderson; James E Bruce
Journal:  J Am Soc Mass Spectrom       Date:  2018-04-24       Impact factor: 3.109

Review 5.  Applications and advancements of FT-ICR-MS for interactome studies.

Authors:  Juan D Chavez; Sung-Gun Park; Jared P Mohr; James E Bruce
Journal:  Mass Spectrom Rev       Date:  2020-12-08       Impact factor: 10.946

6.  Application of frequency multiple FT-ICR-MS signal acquisition for improved proteome research.

Authors:  Sung-Gun Park; Jared P Mohr; Gordon A Anderson; James E Bruce
Journal:  Int J Mass Spectrom       Date:  2021-03-19       Impact factor: 1.934

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.