| Literature DB >> 29686609 |
Rebekah L S Summers1, Mo Chen2,3, Andrea Hatch1, Teresa J Kimberley1.
Abstract
Background: Cerebellar activity can be modulated using cerebellar transcranial direct current stimulation (ctDCS) and, when applied concurrently with task training, has been shown to facilitate cognitive and motor performance. However, how ctDCS facilitates motor performance is not fully understood. Objective/Hypothesis: To assess the electrophysiological and motor performance effects of ctDCS applied during motor training.Entities:
Keywords: cerebellum; corticospinal excitability; motor evoked potential; motor performance; transcranial direct current stimulation; transcranial magnetic stimulation
Year: 2018 PMID: 29686609 PMCID: PMC5900002 DOI: 10.3389/fnhum.2018.00118
Source DB: PubMed Journal: Front Hum Neurosci ISSN: 1662-5161 Impact factor: 3.169
Figure 1Example of transcranial direct current stimulation (tDCS) electrode placement. Active electrode at a midpoint between the level of the mastoid process and inion, along the posterior midline of the head, reference on buccinator muscle ipsilateral to the trained hand.
Pre-test and Post-test data.
| Outcome | Sham | Anodal | ||||
|---|---|---|---|---|---|---|
| Pre | Post | Pre | Post | |||
| MEP Amplitude | 861.70 (361.8) | 1702.30 (1090) | 6 | 1009.80 (432.9) | 708.60 (392.7) | 5 |
| RMT | 41.60 (4.4) | 43.10 (6.0) | 7 | 44.70 (8.7) | 46.10 (8.8) | 7 |
| SICI | 0.20 (0.17) | 0.39 (0.23) | 7 | 0.27 (0.29) | 0.29 (0.26) | 7 |
| CSP | 149.30 (23.0) | 155.9 (30.0) | 7 | 143.20 (12.0) | 166.70 (39.5) | 7 |
| Tracking AI | 11.40 (9.8) | 27.1 (7.6) | 6 | 6.40 (11.5) | 25.90 (9.4) | 6 |
Data are mean (standard deviation). MEP, motor evoked potential, RMT, resting motor threshold; SICI, short-interval intracortical inhibition; CSP, cortical silent period; AI, Accuracy Index; N, number of participants included.
Figure 2Accuracy across training blocks. Blocks 1–6 represent training blocks with simultaneous cerebellar tDCS. A 5-min rest period was given between block 3 and 4. Data are median and range with 95% confidence intervals.
Figure 3Pre-test and post-test data. (A) Motor evoked potential (MEP) amplitude; (B) cortical silent period (CSP) duration; (C) accuracy index (AI). Data are median and range with 95% confidence intervals. *Significant result, p < 0.05.