Literature DB >> 29657894

Evaluation of multiple factors affecting normal brain dose in single-isocenter multiple target radiosurgery.

Yu Yuan1, Evan M Thomas1, Grant A Clark1, James M Markert2, John B Fiveash1, Richard A Popple1.   

Abstract

We investigated the effects of multiple planning factors on normal brain dose for single-isocenter VMAT stereotactic radiosurgery (SRS). Ten patients were retrospectively planned using a standardized objective function and all 16 combinations of 2 versus 4 arcs, collimator angle 45° versus selected per beam to minimize area of normal brain exposed in the beams-eye-view, fixed jaw versus following the trailing MLC leaf, and a 2 Gy mean dose objective for healthy brain versus no low dose objective. Limiting the normal brain mean dose in the optimization objective function significantly reduced the low dose spill into the normal brain without changing target coverage. Jaw tracking and appropriate selection of collimator also reduced the low dose volume, but to a lesser extent. To reduce low dose spill into normal brain for single isocenter VMAT radiosurgery of multiple targets, it is important to incorporate a limit on low dose spill into the objective function. This study has implications beyond single-isocenter VMAT radiosurgery. When comparing different inverse-planned treatment techniques, metrics that are important for evaluation of plan quality must be included the objective function.

Entities:  

Keywords:  SRS; VMAT; brain metastases; linac; radiosurgery

Year:  2018        PMID: 29657894      PMCID: PMC5893454     

Source DB:  PubMed          Journal:  J Radiosurg SBRT


  17 in total

1.  A method for optimizing LINAC treatment geometry for volumetric modulated arc therapy of multiple brain metastases.

Authors:  Jun Kang; Eric C Ford; Koren Smith; John Wong; Todd R McNutt
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

Review 2.  Establishment of practice standards in nomenclature and prescription to enable construction of software and databases for knowledge-based practice review.

Authors:  Charles S Mayo; Thomas M Pisansky; Ivy A Petersen; Elizabeth S Yan; Brian J Davis; Scott L Stafford; Yolanda I Garces; Robert C Miller; James A Martenson; Robert W Mutter; Richard Choo; Christopher L Hallemeier; Nadia N Laack; Sean S Park; Daniel J Ma; Kenneth R Olivier; Sameer R Keole; Mirek Fatyga; Robert L Foote; Michael G Haddock
Journal:  Pract Radiat Oncol       Date:  2016-01-26

3.  Volumetric modulated arc therapy: IMRT in a single gantry arc.

Authors:  Karl Otto
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

4.  Radiation Therapy Oncology Group: radiosurgery quality assurance guidelines.

Authors:  E Shaw; R Kline; M Gillin; L Souhami; A Hirschfeld; R Dinapoli; L Martin
Journal:  Int J Radiat Oncol Biol Phys       Date:  1993-12-01       Impact factor: 7.038

5.  Initial experience with volumetric IMRT (RapidArc) for intracranial stereotactic radiosurgery.

Authors:  Charles S Mayo; Linda Ding; Anthony Addesa; Sidney Kadish; T J Fitzgerald; Richard Moser
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-03-06       Impact factor: 7.038

6.  Use of jaw tracking in intensity modulated and volumetric modulated arc radiation therapy for spine stereotactic radiosurgery.

Authors:  Karen Chin Snyder; Ning Wen; Yimei Huang; Jinkoo Kim; Bo Zhao; Salim Siddiqui; Indrin J Chetty; Samuel Ryu
Journal:  Pract Radiat Oncol       Date:  2014-10-14

7.  12 Gy gamma knife radiosurgical volume is a predictor for radiation necrosis in non-AVM intracranial tumors.

Authors:  Timothy Korytko; Tomas Radivoyevitch; Valdir Colussi; Barry W Wessels; Kunjan Pillai; Robert J Maciunas; Douglas B Einstein
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-10-14       Impact factor: 7.038

8.  Intensity-modulated arc therapy with dynamic multileaf collimation: an alternative to tomotherapy.

Authors:  C X Yu
Journal:  Phys Med Biol       Date:  1995-09       Impact factor: 3.609

9.  Dosimetric effects of jaw tracking in step-and-shoot intensity-modulated radiation therapy.

Authors:  Sarah Joy; George Starkschall; Stephen Kry; Mohammed Salehpour; R Allen White; Steven H Lin; Peter Balter
Journal:  J Appl Clin Med Phys       Date:  2012-03-08       Impact factor: 2.102

10.  Optimization of Treatment Geometry to Reduce Normal Brain Dose in Radiosurgery of Multiple Brain Metastases with Single-Isocenter Volumetric Modulated Arc Therapy.

Authors:  Qixue Wu; Karen Chin Snyder; Chang Liu; Yimei Huang; Bo Zhao; Indrin J Chetty; Ning Wen
Journal:  Sci Rep       Date:  2016-09-30       Impact factor: 4.379

View more
  10 in total

1.  Maximum distance in single-isocenter technique of stereotactic radiosurgery with rotational error using margin-based analysis.

Authors:  Hisashi Nakano; Satoshi Tanabe; Takumi Yamada; Satoru Utsunomiya; Takeshi Takizawa; Madoka Sakai; Ryuta Sasamoto; Hironori Sakai; Toshimichi Nakano; Hirotake Saito; Atsushi Ohta; Motoki Kaidu; Hiroyuki Ishikawa
Journal:  Radiol Phys Technol       Date:  2021-01-03

2.  Simple quality assurance based on filtered back projection for geometrical/irradiation accuracy in single-isocenter multiple-target stereotactic radiotherapy.

Authors:  Naoki Hayashi; Shun Kurata; Yasunori Saito; Shuta Ogawa; Keisuke Yasui
Journal:  Radiol Phys Technol       Date:  2022-10-19

3.  Interinstitutional Plan Quality Assessment of 2 Linac-Based, Single-Isocenter, Multiple Metastasis Radiosurgery Techniques.

Authors:  Haisong Liu; Evan M Thomas; Jun Li; Yan Yu; David Andrews; James M Markert; John B Fiveash; Wenyin Shi; Richard A Popple
Journal:  Adv Radiat Oncol       Date:  2019-12-02

4.  Dosimetric Performance and Planning/Delivery Efficiency of a Dual-Layer Stacked and Staggered MLC on Treating Multiple Small Targets: A Planning Study Based on Single-Isocenter Multi-Target Stereotactic Radiosurgery (SRS) to Brain Metastases.

Authors:  Taoran Li; Peyton Irmen; Haisong Liu; Wenyin Shi; Michelle Alonso-Basanta; Wei Zou; Boon-Keng Kevin Teo; James M Metz; Lei Dong
Journal:  Front Oncol       Date:  2019-01-22       Impact factor: 6.244

Review 5.  Frameless Image-Guided Radiosurgery for Multiple Brain Metastasis Using VMAT: A Review and an Institutional Experience.

Authors:  Samir Abdallah Hanna; Anselmo Mancini; Alisson Henrique Dal Col; Rie Nadia Asso; Wellington Furtado Pimenta Neves-Junior
Journal:  Front Oncol       Date:  2019-08-07       Impact factor: 6.244

6.  Fast stereotactic radiosurgery planning using patient-specific beam angle optimization and automation.

Authors:  Thomas D Mann; Kundan S Thind; Nicolas P Ploquin
Journal:  Phys Imaging Radiat Oncol       Date:  2022-02-26

7.  Detection of rotational errors in single-isocenter multiple-target radiosurgery: Is a routine off-axis Winston-Lutz test necessary?

Authors:  Lauren M M Pudsey; Giordano Biasi; Anna Ralston; Anatoly Rosenfeld; Joel Poder
Journal:  J Appl Clin Med Phys       Date:  2022-06-17       Impact factor: 2.243

8.  Effect of setup error in the single-isocenter technique on stereotactic radiosurgery for multiple brain metastases.

Authors:  Hisashi Nakano; Satoshi Tanabe; Satoru Utsunomiya; Takumi Yamada; Ryuta Sasamoto; Toshimichi Nakano; Hirotake Saito; Takeshi Takizawa; Hironori Sakai; Atsushi Ohta; Eisuke Abe; Motoki Kaidu; Hidefumi Aoyama
Journal:  J Appl Clin Med Phys       Date:  2020-10-29       Impact factor: 2.102

9.  Dosimetric Comparison of Robotic and Linear Accelerator Multi-Leaf Collimator-Based Stereotactic Radiosurgery for Arteriovenous Malformation.

Authors:  Venkatesan Kaliyaperumal; Susan Abraham; Maragatha Veni; Susovan Banerjee; S Tamilselvan; Deepak Gupta; K Dayanithi; D Manigandan; Saumyaranjan Mishra; Shyam Singh Bisht; Tejinder Kataria
Journal:  J Med Phys       Date:  2021-05-05

10.  The use of collimator angle optimization and jaw tracking for VMAT-based single-isocenter multiple-target stereotactic radiosurgery for up to six targets in the Varian Eclipse treatment planning system.

Authors:  Lauren M M Pudsey; Dean Cutajar; Alex Wallace; Anastasia Saba; Laurel Schmidt; Andrej Bece; Catherine Clark; Yoshiya Yamada; Giordano Biasi; Anatoly Rosenfeld; Joel Poder
Journal:  J Appl Clin Med Phys       Date:  2021-07-19       Impact factor: 2.102

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.