Maximum distance in single-isocenter technique of stereotactic radiosurgery with rotational error using margin-based analysis.

Hisashi Nakano1, Satoshi Tanabe2, Takumi Yamada3, Satoru Utsunomiya4, Takeshi Takizawa2,5, Madoka Sakai2, Ryuta Sasamoto4, Hironori Sakai3, Toshimichi Nakano2, Hirotake Saito2, Atsushi Ohta2, Motoki Kaidu6, Hiroyuki Ishikawa6.   

Abstract

Through geometrical simulation, we evaluated the effect of rotational error in patient setup on geometrical coverage and calculated the maximum distance between the isocenter and target, where the clinical PTV margin secures geometrical coverage with a single-isocenter technique. We used simulated spherical GTVs with diameters of 1.0 (GTV 1), 1.5 (GTV 2), 2.0 (GTV 3), and 3.0 cm (GTV 4). The location of the target center was set such that the distance between the target and isocenter ranged from 0 to 15 cm. We created geometrical coverage vectors so that each target was entirely covered by 100% of the prescribed dose. The vectors of the target positions were simultaneously rotated within a range of 0°-2.0° around the x-, y-, and z-axes. For each rotational error, the reduction in geometrical coverage of the targets was calculated and compared with that obtained for a rotational error of 0°. The tolerance value of the geometrical coverage reduction was defined as 5% of the GTV. The maximum distance that satisfied the 5% tolerance value for different values of rotational error at a clinical PTV margin of 0.1 cm was calculated. When the rotational errors were 0.5° for a 0.1 cm PTV margin, the maximum distances were as follows: GTV 1: 7.6 cm; GTV 2: 10.9 cm; GTV 3: 14.3 cm; and GTV 4: 21.4 cm. It might be advisable to exclude targets that are > 7.6 cm away from the isocenter with a single-isocenter technique to satisfy the tolerance value for all GTVs.

Entities:  

Keywords:  PTV margin; Rotational error; Setup error; Single-isocenter technique; VMAT; Volumetric modulated arc therapy

Year:  2021        PMID: 33393057     DOI: 10.1007/s12194-020-00602-2

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  1 in total

1.  Evaluation of multiple factors affecting normal brain dose in single-isocenter multiple target radiosurgery.

Authors:  Yu Yuan; Evan M Thomas; Grant A Clark; James M Markert; John B Fiveash; Richard A Popple
Journal:  J Radiosurg SBRT       Date:  2018
  1 in total
  2 in total

1.  Detection of rotational errors in single-isocenter multiple-target radiosurgery: Is a routine off-axis Winston-Lutz test necessary?

Authors:  Lauren M M Pudsey; Giordano Biasi; Anna Ralston; Anatoly Rosenfeld; Joel Poder
Journal:  J Appl Clin Med Phys       Date:  2022-06-17       Impact factor: 2.243

2.  Radiobiological evaluation considering setup error on single-isocenter irradiation in stereotactic radiosurgery.

Authors:  Hisashi Nakano; Satoshi Tanabe; Ryuta Sasamoto; Takeshi Takizawa; Satoru Utsunomiya; Madoka Sakai; Toshimichi Nakano; Atsushi Ohta; Motoki Kaidu; Hiroyuki Ishikawa
Journal:  J Appl Clin Med Phys       Date:  2021-06-20       Impact factor: 2.102

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.