Literature DB >> 29657466

A long-term comparative study between two different designs of cemented stems: Distal-cylindrical versus distal-taper.

Yuki Okutani1, Koji Goto1, Tomotoshi Kawata1, Yaichiro Okuzu1, Kazutaka So2, Yutaka Kuroda1, Shuichi Matsuda1.   

Abstract

INTRODUCTION: The aim of this study was to calculate the wear rate of highly cross-linked polyethylene (HXLPE) and investigate long-term clinical and radiographic outcomes related to two femoral stem designs, the distal-cylindrical (DC) and distal-taper (DT) stems.
MATERIALS AND METHODS: Outcomes for the DC and DT stems were evaluated in 110 patients, who underwent total hip arthroplasty using an HXLPE socket, over a 5-year follow-up period. There were 56 hips (53 patients) in the DC group and 60 hips (57 patients) in the DT group. Clinical outcomes were measured using the Japanese Orthopaedic Association (JOA) score and radiographic changes. Polyethylene wear rate was calculated using a computer software.
RESULTS: The mean follow-up period was 135.7 and 124.0 months for the DC and DT groups, respectively. Both stem designs improved hip function. On radiographic assessment, osteolysis around the tip of the stem was more frequent in the DC than in the DT group. Three cases of aseptic loosening of the stem were identified in the DC group, and no cases were identified in the DT group. The 10-year stem survival, using aseptic loosening as the primary endpoint, was 94.1% and 100% for the DC and DT groups, respectively (p = 0.06). The polyethylene wear rate was comparable for both stem groups.
CONCLUSION: Better clinical outcomes were obtained with the DT stem than with the DC stem regardless of the equivalent polyethylene wear rate for the two designs. The DC shape of the stem may increase the risk of aseptic loosening.

Entities:  

Keywords:  Cemented THA; Highly cross-linked polyethylene; Polyethylene wear; Stem design

Year:  2018        PMID: 29657466      PMCID: PMC5895896          DOI: 10.1016/j.jor.2018.01.019

Source DB:  PubMed          Journal:  J Orthop        ISSN: 0972-978X


  15 in total

1.  The Exeter universal cemented femoral component at 8 to 12 years. A study of the first 325 hips.

Authors:  H D W Williams; G Browne; G A Gie; R S M Ling; A J Timperley; N A Wendover
Journal:  J Bone Joint Surg Br       Date:  2002-04

Review 2.  The 'French paradox.'.

Authors:  F Langlais; M Kerboull; L Sedel; R S M Ling
Journal:  J Bone Joint Surg Br       Date:  2003-01

3.  Highly crosslinked polyethylene does not reduce aseptic loosening in cemented THA 10-year findings of a randomized study.

Authors:  Per-Erik Johanson; Georgios Digas; Peter Herberts; Jonas Thanner; Johan Kärrholm
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

4.  The type of cement and failure of total hip replacements.

Authors:  B Espehaug; O Furnes; L I Havelin; L B Engesaeter; S E Vollset
Journal:  J Bone Joint Surg Br       Date:  2002-08

5.  Clinical results of the wear performance of cross-linked polyethylene in total hip arthroplasty: prospective randomized trial.

Authors:  Kentaro Ise; Keiichi Kawanabe; Jiro Tamura; Haruhiko Akiyama; Koji Goto; Takashi Nakamura
Journal:  J Arthroplasty       Date:  2009-08-12       Impact factor: 4.757

6.  Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. A 12-year radiographic review.

Authors:  R L Barrack; R D Mulroy; W H Harris
Journal:  J Bone Joint Surg Br       Date:  1992-05

7.  Clinical outcomes of cemented double-tapered titanium femoral stems: a minimum 5-year follow-up.

Authors:  Haruhiko Akiyama; Keiichi Kawanabe; Koji Yamamoto; Kazutaka So; Yutaka Kuroda; Takashi Nakamura
Journal:  J Orthop Sci       Date:  2011-09-16       Impact factor: 1.601

8.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening.

Authors:  T A Gruen; G M McNeice; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1979-06       Impact factor: 4.176

9.  Influence of stem geometry on the stability of polished tapered cemented femoral stems.

Authors:  S Glyn-Jones; H S Gill; D J Beard; P McLardy-Smith; D W Murray
Journal:  J Bone Joint Surg Br       Date:  2005-07

10.  Distal cortical hypertrophy following total hip arthroplasty.

Authors:  M A Ritter; R W Fechtman
Journal:  J Arthroplasty       Date:  1988       Impact factor: 4.757

View more
  1 in total

1.  The superior accuracy of a novel method in total hip wear calculations following radiographic measurement.

Authors:  Kazutaka So; Koji Goto; Atsushi Kawaguchi; Yutaka Kuroda; Shuichi Matsuda
Journal:  BMC Musculoskelet Disord       Date:  2022-02-09       Impact factor: 2.362

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.