Literature DB >> 12211673

The type of cement and failure of total hip replacements.

B Espehaug1, O Furnes, L I Havelin, L B Engesaeter, S E Vollset.   

Abstract

Using data from the Norwegian Arthroplasty egister, we have assessed the survival of 17 323 primary Charnley hip prostheses in patients with osteoarthritis based upon the type of cement used for the fixation of the implant. Overall, 9.2% had been revised after follow-up for ten years; 71% of the failures involved aseptic loosening of the femoral component. We observed significantly increased rates of failure for prostheses inserted with CMW1 and CMW3 cements. Using implants fixed with gentamicin-containing Palacos cement as the reference, the adjusted Cox regression failure rate ratios were 1.1 (95% CI 0.9 to 1.4) for implants cemented with plain Palacos, 1.1 (95% CI 0.7 to 1.6) for Simplex, 2.1 (95% 1.5 to 2.9) for gentamicin-containing CMW1, 2.0 (95% CI 1.6 to 2.4) for plain CMW1 and 3.0 (95% CI 2.3 to 3.9) for implants fixed with CMW3 cement. The adjusted failure rate at ten years varied from 5.9% for implants fixed with gentamicin-containing Palacos to 17% for those fixed with CMW3.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12211673     DOI: 10.1302/0301-620x.84b6.12776

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  20 in total

1.  Cement-implant interface gaps explain the poor results of CMW3 for femoral stem fixation: A cadaver study of migration, fatigue and mantle morphology.

Authors:  Amos Race; Mark A Miller; Michael T Clarke; Kenneth A Mann
Journal:  Acta Orthop       Date:  2005-10       Impact factor: 3.717

2.  A comparison of the minimum data sets for primary shoulder arthroplasty between national shoulder arthroplasty registries. Is international harmonization feasible?

Authors:  Ricardo Aveledo; Phillip Holland; Michael Thomas; Fiona Ashton; Amar Rangan
Journal:  Shoulder Elbow       Date:  2018-02-15

Review 3.  Use of antibiotic-loaded cement in total knee arthroplasty.

Authors:  Pedro Hinarejos; Pau Guirro; Lluis Puig-Verdie; Raul Torres-Claramunt; Joan Leal-Blanquet; Juan Sanchez-Soler; Joan Carles Monllau
Journal:  World J Orthop       Date:  2015-12-18

4.  Subsidence of titanium straight stems in combination with highly viscous bone cement.

Authors:  Christian Hendrich; Ulf Sauer; Tobias Albrecht; Christof P Rader
Journal:  Int Orthop       Date:  2005-02-10       Impact factor: 3.075

5.  The Elite-Plus stem migrates more than the flanged Charnley stem.

Authors:  Thord von Schewelov; Lennart Sanzén; Jack Besjakov; Ake Carlsson
Journal:  Acta Orthop       Date:  2010-06       Impact factor: 3.717

6.  A long-term comparative study between two different designs of cemented stems: Distal-cylindrical versus distal-taper.

Authors:  Yuki Okutani; Koji Goto; Tomotoshi Kawata; Yaichiro Okuzu; Kazutaka So; Yutaka Kuroda; Shuichi Matsuda
Journal:  J Orthop       Date:  2018-02-02

7.  Introduction of total knee arthroplasty in Lithuania: Results from the first 10 years.

Authors:  Sarunas Tarasevicius; Justinas Stucinskas; Otto Robertsson; Hans Wingstrand
Journal:  Acta Orthop       Date:  2009-02       Impact factor: 3.717

8.  Risk factors for revision after shoulder arthroplasty: 1,825 shoulder arthroplasties from the Norwegian Arthroplasty Register.

Authors:  Bjørg-Tilde S Fevang; Stein A Lie; Leif I Havelin; Arne Skredderstuen; Ove Furnes
Journal:  Acta Orthop       Date:  2009-02       Impact factor: 3.717

9.  18 years of results with cemented primary hip prostheses in the Norwegian Arthroplasty Register: concerns about some newer implants.

Authors:  Birgitte Espehaug; Ove Furnes; Lars B Engesaeter; Leif I Havelin
Journal:  Acta Orthop       Date:  2009-08       Impact factor: 3.717

Review 10.  Early proximal migration of cups is associated with late revision in THA: a systematic review and meta-analysis of 26 RSA studies and 49 survivalstudies.

Authors:  Bart G Pijls; Marc J Nieuwenhuijse; Marta Fiocco; Josepha Wm Plevier; Saskia Middeldorp; Rob Ghh Nelissen; Edward R Valstar
Journal:  Acta Orthop       Date:  2012-11-05       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.