Literature DB >> 19679444

Clinical results of the wear performance of cross-linked polyethylene in total hip arthroplasty: prospective randomized trial.

Kentaro Ise1, Keiichi Kawanabe, Jiro Tamura, Haruhiko Akiyama, Koji Goto, Takashi Nakamura.   

Abstract

To investigate the clinical results of cross-linked polyethylene (CLPE) and to compare the CLPE wear against zirconia and stainless steel heads, we studied the radiographic wear after a minimum 3-year follow-up in total hip arthroplasty (THA). Ninety-four hips were randomly implanted with a 22.225-mm head cemented THA-the group of non-CLPE against zirconia and CLPE against 2 different zirconias and stainless steel. The linear wear rate was significantly lower in the group of CLPE against zirconia (0.067, 0.059 mm/y) and against stainless steel (0.068 mm/y) compared with non-CLPE against zirconia (0.170 mm/y). In the short-term results, the wear performance of CLPE against zirconia was superior to that of non-CLPE; however, it did not show a better wear rate than CLPE against stainless steel. Furthermore, long-term investigations will be necessary for understanding CLPE wear in vivo.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19679444     DOI: 10.1016/j.arth.2009.05.020

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  7 in total

1.  Reduced wear of cross-linked UHMWPE using magnesia-stabilized zirconia femoral heads in a hip simulator.

Authors:  Marcel E Roy; Leo A Whiteside; Mark E Magill; Brian J Katerberg
Journal:  Clin Orthop Relat Res       Date:  2011-02-11       Impact factor: 4.176

Review 2.  History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene.

Authors:  Steven M Kurtz; Heather A Gawel; Jasmine D Patel
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

3.  Wear Rates of XLPE Nearly 50% Lower Than Previously Thought After Adjusting for Initial Creep: An RCT Comparing 4 Bearing Combinations.

Authors:  Amir Khoshbin; James Wu; Sarah Ward; Luana T Melo; Emil H Schemitsch; James P Waddell; Amit Atrey
Journal:  JB JS Open Access       Date:  2020-06-05

4.  Polyethylene and highly cross-linked polyethylene for cemented total hip arthroplasty: A comparison of over ten-year clinical and radiographic results.

Authors:  Tomotoshi Kawata; Koji Goto; Kazutaka So; Yutaka Kuroda; Shuichi Matsuda
Journal:  J Orthop       Date:  2017-08-10

5.  Natural polyphenols enhance stability of crosslinked UHMWPE for joint implants.

Authors:  Jie Shen; Guorong Gao; Xincai Liu; Jun Fu
Journal:  Clin Orthop Relat Res       Date:  2015-03       Impact factor: 4.176

6.  A long-term comparative study between two different designs of cemented stems: Distal-cylindrical versus distal-taper.

Authors:  Yuki Okutani; Koji Goto; Tomotoshi Kawata; Yaichiro Okuzu; Kazutaka So; Yutaka Kuroda; Shuichi Matsuda
Journal:  J Orthop       Date:  2018-02-02

7.  The superior accuracy of a novel method in total hip wear calculations following radiographic measurement.

Authors:  Kazutaka So; Koji Goto; Atsushi Kawaguchi; Yutaka Kuroda; Shuichi Matsuda
Journal:  BMC Musculoskelet Disord       Date:  2022-02-09       Impact factor: 2.362

  7 in total