Influence of stem geometry on the stability of polished tapered cemented femoral stems.

S Glyn-Jones1, H S Gill, D J Beard, P McLardy-Smith, D W Murray.   

Abstract

Polished, tapered stems are now widely used for cemented total hip replacement and many such designs have been introduced. However, a change in stem geometry may have a profound influence on stability. Stems with a wide, rectangular proximal section may be more stable than those which are narrower proximally. We examined the influence of proximal geometry on stability by comparing the two-year migration of the Exeter stem with a more recent design, the CPS-Plus, which has a wider shoulder and a more rectangular cross-section. The hypothesis was that these design features would increase rotational stability. Both stems subsided approximately 1 mm relative to the femur during the first two years after implantation. The Exeter stem was found to rotate into valgus (mean 0.2 degrees , sd 0.42 degrees ) and internally rotate (mean 1.28 degrees , sd 0.99 degrees ). The CPS-Plus showed no significant valgus rotation (mean 0.07 [correction] degrees, sd 0.29 [correction] degrees ) or internal rotation (mean -0.03 degrees , sd 0.75 degrees ). A wider, more rectangular cross-section improves rotational stability and may have a better long-term outcome.

Entities:  

Mesh:

Year:  2005        PMID: 15972903     DOI: 10.1302/0301-620X.87B7.16079

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  5 in total

1.  A long-term comparative study between two different designs of cemented stems: Distal-cylindrical versus distal-taper.

Authors:  Yuki Okutani; Koji Goto; Tomotoshi Kawata; Yaichiro Okuzu; Kazutaka So; Yutaka Kuroda; Shuichi Matsuda
Journal:  J Orthop       Date:  2018-02-02

2.  Migration pattern of cemented Exeter short stem in Dorr type A femurs. A prospective radiostereometry study with 2-year follow-up.

Authors:  Tobias Dahl Vind; Peter Bo Jørgensen; Dovydas Vainorius; Stig Storgaard Jakobsen; Kjeld Søballe; Maiken Stilling
Journal:  Arch Orthop Trauma Surg       Date:  2022-02-03       Impact factor: 3.067

3.  Migration and strains induced by different designs of force-closed stems for THA.

Authors:  Sandro Griza; Luiz Sérgio Marcelino Gomes; André Cervieri; Telmo Roberto Strohaecker
Journal:  Rev Bras Ortop       Date:  2015-10-23

4.  Fixation of the cemented stem: clinical relevance of the porosity and thickness of the cement mantle.

Authors:  Philippe Hernigou; Gildasio Daltro; Charles Henri Flouzat Lachaniette; Xavier Roussignol; Martin Mukisi Mukasa; Alexandre Poignard
Journal:  Open Orthop J       Date:  2009-02-12

Review 5.  Temporal subsidence patterns of cemented polished taper-slip stems: a systematic review.

Authors:  Kwaku Baryeh; Jeewaka Mendis; David H Sochart
Journal:  EFORT Open Rev       Date:  2021-05-04
  5 in total