Proprioceptive and cutaneous sensations in humans elicited by intracortical microstimulation.

Michelle Armenta Salas1,2, Luke Bashford1,2, Spencer Kellis1,2,3,4, Matiar Jafari1,2,5, HyeongChan Jo1,2, Daniel Kramer3,4, Kathleen Shanfield6, Kelsie Pejsa1,2, Brian Lee3,4, Charles Y Liu3,4,6, Richard A Andersen1,2.   

Abstract

Pioneering work with nonhuman primates and recent human studies established intracortical microstimulation (ICMS) in primary somatosensory cortex (S1) as a method of inducing discriminable artificial sensation. However, these artificial sensations do not yet provide the breadth of cutaneous and proprioceptive percepts available through natural stimulation. In a tetraplegic human with two microelectrode arrays implanted in S1, we report replicable elicitations of sensations in both the cutaneous and proprioceptive modalities localized to the contralateral arm, dependent on both amplitude and frequency of stimulation. Furthermore, we found a subset of electrodes that exhibited multimodal properties, and that proprioceptive percepts on these electrodes were associated with higher amplitudes, irrespective of the frequency. These novel results demonstrate the ability to provide naturalistic percepts through ICMS that can more closely mimic the body's natural physiological capabilities. Furthermore, delivering both cutaneous and proprioceptive sensations through artificial somatosensory feedback could improve performance and embodiment in brain-machine interfaces.
© 2018, Armenta Salas et al.

Entities:  

Keywords:  brain-machine interface; human; intracortical microstimulation; neuroscience; proprioception; somatosensation; somatosensory cortex

Mesh:

Year:  2018        PMID: 29633714      PMCID: PMC5896877          DOI: 10.7554/eLife.32904

Source DB:  PubMed          Journal:  Elife        ISSN: 2050-084X            Impact factor:   8.140


Introduction

The absence of somatosensation profoundly diminishes a person’s ability to move and interact within their environment (Cole and Cole, 1995; Sainburg et al., 1993). Even with intact vision and hearing, which can provide sensory information about body position, movement, and interaction, basic behaviors such as walking or reach-and-grasp require substantially greater cognitive load without somatosensory feedback. The severity of these deficits underscores how deeply integrated cutaneous and proprioceptive somatosensations are in the neural control of movement, and motivates the problem of restoring sensation when it is missing. However, the complexity of the somatosensory circuit, and the difficulty of writing information into this circuit with sufficient integrity, have posed significant challenges. Recent advances in brain-machine interface (BMI) technology have led to renewed efforts in this area, under the hypothesis that providing closed-loop motor-sensory control and feedback pathways could lead to vital increases in performance (Bensmaia and Miller, 2014). Intracortical microstimulation (ICMS) is a promising technique for implementing a return path in which electrical stimuli are written directly into the somatosensory cortex through implanted electrode arrays. Non-human primates (NHPs) successfully incorporated ICMS information to perform discrimination, detection tasks (Romo et al., 1998; Romo et al., 2000; Tabot et al., 2013; Dadarlat et al., 2015) and as sensory feedback for brain control in BMI tasks (O'Doherty et al., 2011; Klaes et al., 2014), and recent human studies have provided insight into the feeling and perception of the sensations produced through ICMS (Flesher et al., 2016). However, qualities ascribed by human subjects to these sensations (e.g., ‘tingling’ or ‘buzzing’) have been mostly artificial in nature (Johnson et al., 2013; Flesher et al., 2016), and it is as yet unclear what range of sensations could be elicited through ICMS. Here, we present novel findings from two experiments: one which tested each electrode over a range of amplitudes with fixed frequency, and one which tested a subset of electrodes over a range of amplitudes and frequencies. We found reliable elicitation of natural cutaneous and proprioceptive sensations spanning a range of stimulus amplitudes and frequencies, obtained from stimulation in S1 of a single human subject (participant FG, Figure 1; see Materials and methods) with a C5-level spinal cord injury. We further show that current amplitude, not frequency, of the electrical stimulus differentiates the modality (i.e., cutaneous or proprioceptive) of the elicited percept at some stimulation sites.
Figure 1.

Array implant locations on rendered MRI image of the left hemisphere of FG.

96-channel microelectrode arrays were implanted into ventral premotor cortex (PMv) and supramarginal gyrus (SMG), and two 48-channel stimulating arrays were implanted into primary somatosensory cortex (S1). The insert shows the in situ array locations.

Array implant locations on rendered MRI image of the left hemisphere of FG.

96-channel microelectrode arrays were implanted into ventral premotor cortex (PMv) and supramarginal gyrus (SMG), and two 48-channel stimulating arrays were implanted into primary somatosensory cortex (S1). The insert shows the in situ array locations.

Results and discussion

In Experiment 1, over an eight-week period, electrical stimuli were tested across a range of current amplitudes between 20–100 µA, with pulse frequency held constant at 150 Hz (see Materials and methods). Stimulation through 46/96 electrodes (48%) prompted at least one response, and there were in total 381 reported sensations out of 1229 non-catch trials (see Materials and methods). There was weak correlation between the number of electrodes that elicited a sensation and the current amplitude (r = 0.34, p=0.42, Pearson linear correlation). Additionally, we found no correlation between electrode impedance and the likelihood of elicited percepts (p=0.80, Pearson linear correlation coefficient), pooling all electrode responses over all days. Furthermore, there was no significant difference in the aggregate impedances of either electrodes that produced or did not produce percepts (p=0.707, Kolmogorov-Smirnov two-sample test). No false positives were reported in any catch trials, and we found no effect of trial history in the proportion of reported sensations during stimulation (see Materials and methods). The stimulation did not trigger any painful sensations, and no adverse events occurred during any of the sessions. Receptive fields along the upper arm, forearm and hand corresponded to coarse somatotopical organization in the corresponding stimulation sites. Figure 2 shows the most frequently reported receptive field and sensation modality for each electrode across all trials. Of the 46 electrodes with responses, 32 evoked percepts in the upper arm, 18 in the forearm, and two in the hand (palmar surface of digits and a finger pad). In agreement with previous reports, stimulation could produce percepts with variably-sized receptive fields in different electrodes (Flesher et al., 2016). For the majority of electrodes (24/46), receptive fields were reported in the same body region (i.e. upper arm or forearm) or in the same plane (i.e. anterior or posterior) across all tested amplitudes. Coarse somatotopy was present between the medial and lateral arrays (Figure 2B); the medial array was more likely to have reliable receptive fields in the anterior upper arm (46% of medial-array receptive fields), while stimulation on the lateral array induced sensation more frequently on the posterior forearm (51% of lateral-array receptive fields). However, there was no clear somatotopical organization within each array as previously reported (Kim et al., 2015a; Kaas, 1983; Flesher et al., 2016). The coarse somatotopy found across arrays but not within arrays, could be due to the small area of cortex sampled by the implants, and the fact that the implants predominantly covered upper arm and forearm, areas with a less established somatotopic map (Kaas et al., 1979; Kaas, 1983). Another plausible explanation is that the topography in somatosensory cortex has been remapped after injury (Kaas et al., 1983; Florence et al., 1998; Moore et al., 2000)
Figure 2.

Receptive fields and sensation modality across all amplitude mapping experiments.

(A) Receptive field location on anterior (lighter shades) and posterior (darker shades) planes of the right upper arm (green), forearm (pink), and hand (cyan). Grid is the same that the subject referenced during the experiment. (B) Schematic of the two electrode arrays implanted over S1 (Figure 1). Left side panels display the reported receptive fields at each electrode location, and right side panels display the sensation modality (cutaneous - red, proprioceptive - blue). Light gray boxes show electrodes with no reported sensation, while dark gray boxes represent reference channels which are not used in recording. The five electrodes with a thick black outline represent the subset tested in the additional parameter-wide mapping task. Yellow and magenta asterisks mark the inferior-posterior corner of the implants, for the medial and lateral arrays respectively.

Receptive fields and sensation modality across all amplitude mapping experiments.

(A) Receptive field location on anterior (lighter shades) and posterior (darker shades) planes of the right upper arm (green), forearm (pink), and hand (cyan). Grid is the same that the subject referenced during the experiment. (B) Schematic of the two electrode arrays implanted over S1 (Figure 1). Left side panels display the reported receptive fields at each electrode location, and right side panels display the sensation modality (cutaneous - red, proprioceptive - blue). Light gray boxes show electrodes with no reported sensation, while dark gray boxes represent reference channels which are not used in recording. The five electrodes with a thick black outline represent the subset tested in the additional parameter-wide mapping task. Yellow and magenta asterisks mark the inferior-posterior corner of the implants, for the medial and lateral arrays respectively. FG has reported a wealth of qualitative sensations induced by ICMS (Table 1). Unlike paresthetic sensations experienced post-injury, these naturalistic responses were broadly characterized as cutaneous (e.g. squeeze) or proprioceptive (e.g. rightward movement), and as being subjectively similar to sensations experienced prior to injury. At his own discretion, the subject used single-word descriptors to characterize the perceived sensations as accurately as possible. Single-word descriptors have the advantage that they can be compared across large data sets or subjects. However, as experimental advances continue to push the capabilities of ICMS, responses could become more complex and future studies might benefit from more structured descriptors, which take into consideration the complexity of these sensory experiences (Darie et al., 2017).
Table 1.

Descriptions of the most prevalent sensations by percentage of total responses.

Entries cover 90% of 381 reported sensations, with the final 10% comprising a mixture of other naturalistic cutaneous and proprioceptive descriptors. Each sensation is accompanied by the mode and 25th-75th percentiles in the distribution of amplitudes that elicited each sensation, and by the same quantities for the perceived reported intensities (on a scale of 1 [weak] to 10 [strong]).

Description% Total Sensations (381 total)Amplitude μA (mode)Amplitude μA (25th, 75th percentile)Intensity (mode)Intensity (25th, 75th percentile)
Squeeze24.94040, 87.574, 7
Tap17.37040, 8011, 4
Right movement9.79055, 9011, 3
Vibration8.14040, 9022, 3
Blowing6.66030, 8011, 2
Forward Movement5.87040, 8011, 4
Pinch5.54040, 9033, 6
Press5.04040, 7074, 7
Upward Movement3.97070, 8511.25, 4
Goosebumps3.110060, 9052, 5

Descriptions of the most prevalent sensations by percentage of total responses.

Entries cover 90% of 381 reported sensations, with the final 10% comprising a mixture of other naturalistic cutaneous and proprioceptive descriptors. Each sensation is accompanied by the mode and 25th-75th percentiles in the distribution of amplitudes that elicited each sensation, and by the same quantities for the perceived reported intensities (on a scale of 1 [weak] to 10 [strong]). We found that 18 electrodes had cutaneous-only responses across all tested current amplitudes, while six electrodes had proprioceptive-only responses; the rest of the electrodes (22/46) had mixed responses, where the perceived modality (cutaneous or proprioceptive) varied as stimulus parameters changed. Of these mixed-response electrodes, 45% evoked mostly cutaneous sensations, 32% evoked mostly proprioceptive sensations, and 23% had an equal number of cutaneous and proprioceptive sensations (Figure 2B). This pattern of cutaneous and proprioceptive evoked sensations complements recent reports of multimodal (i.e. cutaneous and proprioceptive) neurons throughout S1 (Yau et al., 2016; Kim et al., 2015b). While prior single-unit experiments have defined maps from single neurons to specific unimodal receptive fields (Kaas et al., 1979; Kaas, 1983; Friedman et al., 2004; Romo et al., 2000), the above results suggest that more than one variable may be represented when mapping with ICMS. This finding may be the product of different mechanisms by which receptive fields are observed through recording versus stimulation, and could be an important topic for future work. We found a significant difference between the amplitudes that elicited cutaneous or proprioceptive responses, with the distribution of proprioceptive responses skewed towards higher amplitudes (Figure 3A), when pooling across all electrodes and amplitudes that produced a sensation (p=0.039, Kruskal-Wallis nonparametric ANOVA, χ2(1,378)=4.41, proprioceptive responses N = 79, cutaneous responses N = 302). To assess consistent current delivery across all electrodes, we measured electrode impedance at the beginning of every session and found no significant difference when comparing proprioceptive or cutaneous responses (p=0.237, χ2(1,378)=1.39) and, furthermore, we found no significant difference between the impedance of proprioceptive- and cutaneous-only (p=0.922, χ2(1,155)=0.01) or mixed-response electrodes (p=0.372, χ2(1,221)=0.8). To account for potential bias from an uneven distribution of responses across amplitudes, we compared the proportion of proprioceptive and cutaneous responses in a bootstrapped resampling (N = 10000), in which each repetition drew 15 responses at each amplitude from all data pooled across days (Figure 3B). We observed a clear relationship between the number of proprioceptive and cutaneous responses and stimulation amplitudes, measured through overall positive slopes in the 1st-order polynomial fit at each iteration for proprioceptive responses, and negative slopes for cutaneous responses (Figure 3C).
Figure 3.

Proprioceptive and cutaneous responses.

(A) Kernel density estimate and box plot showing the difference in the distribution of amplitudes associated with each report of proprioceptive (blue) or cutaneous (red) responses. (B) The median percentage of responses in the bootstrapped sample (solid line) for proprioceptive and cutaneous responses at each amplitude tested. Dashed line shows 1st-order polynomial fit. (C) Kernel density estimates of the distribution of slopes from 1st-order polynomial fits in each bootstrap iteration. (D) Pie charts show the percentage of total stimulations of responses for the subset of electrodes tested over a range of both current amplitudes and pulse frequencies. The left panel shows an individual example electrode (six trials per combination of amplitude and frequency) and the right panel shows data pooled over all five electrodes (30 total stimulations per combination). The percentage of no response (white), proprioceptive (blue) or cutaneous (red) are shown. (E) A normalized histogram of proprioceptive (blue) and cutaneous (red) responses at each of the amplitudes tested in experiment 2.

Proprioceptive and cutaneous responses.

(A) Kernel density estimate and box plot showing the difference in the distribution of amplitudes associated with each report of proprioceptive (blue) or cutaneous (red) responses. (B) The median percentage of responses in the bootstrapped sample (solid line) for proprioceptive and cutaneous responses at each amplitude tested. Dashed line shows 1st-order polynomial fit. (C) Kernel density estimates of the distribution of slopes from 1st-order polynomial fits in each bootstrap iteration. (D) Pie charts show the percentage of total stimulations of responses for the subset of electrodes tested over a range of both current amplitudes and pulse frequencies. The left panel shows an individual example electrode (six trials per combination of amplitude and frequency) and the right panel shows data pooled over all five electrodes (30 total stimulations per combination). The percentage of no response (white), proprioceptive (blue) or cutaneous (red) are shown. (E) A normalized histogram of proprioceptive (blue) and cutaneous (red) responses at each of the amplitudes tested in experiment 2. Experiment 2 tested a subset of 5 electrodes with robust responses across all tested amplitudes in Experiment 1 (Figure 2B, Figure 3D). In a pseudorandomly-interleaved fashion, we stimulated each electrode with five amplitudes (range 20 to 100 μA) at six different frequencies (range 50 to 300 Hz) over the course of three consecutive days (see Materials and methods). We reproduced the effect of amplitude on sensation modality, either proprioceptive or cutaneous, when pooling across all responses (p=2×10−5, χ2(1323)= 18.17, Figure 3E). Similar to the main mapping task, we did not find any significant effect on modality due to electrode impedance (p=0.305, χ2(1323)=0.8). Furthermore, there was no significance when testing the effect of frequency in eliciting proprioceptive or cutaneous responses (p=0.22, χ2(1323)= 1.48). This amplitude-specific effect on sensation modality is perhaps surprising given the more commonly observed effect of frequency and pulse-width modulation on sensation in the periphery (Graczyk et al., 2016). Although there is evidence of tactile and proprioceptive inputs co-modulating S1 firing activity (Kim et al., 2015b), we are unaware of any reported effect of amplitude or frequency thresholding for different sensory modalities in the CNS. Proprioceptive sensations are commonly thought to derive from activity in areas 2 or 3a, while cutaneous sensations more likely correspond to activity in areas 3b and 1. From topographical features, we estimate our implants lie in area 1; however, with evidence of interindividual variability in the microstructural organization within S1 (Geyer et al., 1999), and the potential for functional reorganization after injury (Kaas et al., 1983; Florence et al., 1998), it is possible that higher current amplitudes could increase the effective range of stimulation to include sensory areas 3a or 2. Moreover, given the receptive fields activated during stimulation, the two implants are well within the arm and forearm regions of S1, which might receive a larger ratio of proprioceptive-to-cutaneous signals than hand regions (McKenna et al., 1982), making it more likely to activate these different modalities with ICMS. FG also provided subjective measures of sensation intensity and duration. Sensation intensity was ranked from 1 to 10 (weakest to strongest). In Experiment 1, we found a strong positive correlation between intensity and amplitude (r = 0.2, p=2.1×10−5, Pearson linear correlation coefficient), with an intensity of 2.4 ± 1.9 a.u. (mean ±s.d.) for 20 μA and 4.0 ± 2.1 a.u. for 100 μA, with a slope of 0.02 (1st-order polynomial, least squares fitting). As subjective measures of intensity are most likely sensitive to day-to-day variability, in post-hoc analysis we also normalized intensity values within each session (see Materials and methods). We measured a negative correlation between the current amplitude and the standard deviation of the intensity (r = −0.6, p=0.12). Duration of the percept was recorded for each response as either short (sensation lasts only briefly at the onset of stimulation), medium (sensation persists throughout the stimulation but not for the full length of the stimulation) or long (sensation lasts the full duration of the stimulation). The majority of responses were short (N = 225), followed by medium (N = 122) with very few long responses (N = 12). Stimulus duration was not recorded for 22 responses of the 381 responses. For Experiment 2 this trend was replicated (N = 268, 55 and 1. Short, medium and long, respectively). There was no relationship between duration of the sensation and either amplitude of stimulation (p=0.1, χ2(1323)=4.53) or frequency of stimulation (p=0.2, χ2(1323)=2.83). To our knowledge, this is the first report in human of replicable, purely naturalistic proprioceptive and cutaneous sensations induced through ICMS. Stimulation over a wide range of amplitudes and frequencies generated qualitatively diverse sensations, although percept modality was strongly linked to variations in amplitude. Pairing these natural sensations with BMIs create a unique opportunity to explore how effectively they can be incorporated in a closed-loop BMI system. For example, the ability to evoke proprioceptive sensations could allow the subject to interpret position- or movement-related information, as previously reported in primate studies (Tomlinson and Miller, 2016; Dadarlat et al., 2015), while eliciting cutaneous sensations could improve our ability to deliver richer somatosensory feedback for object manipulation. Together these somatosensory signals have the potential to improve performance and embodiment when using a BMI-controlled external device.

Materials and methods

Subject

We recruited and consented a 32-year-old male participant (FG) with C5-level complete spinal cord injury, 1.5 years post-injury, to participate in a clinical trial of a BMI system with intracortical recording and stimulation. The subject has residual sensation in the anterior-radial section of his upper arm, and some residual sensation in the posterior-radial section of his upper arm and forearm, which present as paresthesias. All procedures were approved by the Institutional Review Boards (IRB) of the University of Southern California (USC) and Rancho Los Amigos National Rehabilitation Hospital (RLA). The implant procedure occurred at Keck Hospital of USC, and study sessions took place at RLA.

Surgical planning and implantation

Surgical planning followed the protocols described in (Aflalo et al., 2015), with an additional task for identifying an implant location within somatosensory cortex. In this task, a visual cue prompted the experimenter, who was standing next to the MRI, to reach into the MRI machine with a wooden pole and repeatedly press at one of three points on the subjects right upper limb where he previously reported residual paresthetic sensation; biceps, forearm and thenar eminence. The subject was instructed to attend to any residual sensation he felt at each location and report the number of times the experimenter touched him on the cued location (Kastner et al., 1998; Staines et al., 2002). After functional imaging, three target locations for electrode placement were identified; supramarginal gyrus (SMG), ventral premotor cortex (PMv) and primary somatosensory cortex (S1). One 96-channel, platinum-tipped Neuroport microelectrode recording array (Blackrock Microsystems, Salt Lake City, UT) was implanted in each of SMG and PMv. Two 7 × 7 SIROF (sputtered iridium oxide film)-tipped microelectrode arrays (with 48 physically-connected channels each) were implanted in S1. The SIROF-tipped electrodes have lower impedance than the platinum-tipped electrodes, and thus are better suited to stimulation.

Stimulation and recording parameters

All stimuli consisted of biphasic, charge-balanced, cathodic-leading pulses, with 200 µs width per phase, 53 µs interphase interval, and one-second stimulus duration delivered to a single electrode on the S1 array only. The maximum charge delivered per phase was 20 nC. We selected these parameters, and set electric charge limits according to safe ranges shown in ICMS studies with NHPs (Kim et al., 2015a). Stimulation was delivered with a Blackrock CereStim device, and stimulation parameters were set and delivered using the CereStim API through MATLAB (The Mathworks Inc, Natick, MA) software (MATLAB code in Source code file 1).

Task

Experiment 1: After initial assessment of implant viability, we evaluated the effects of stimulation parameters through a percept-detection task. For this primary mapping task, each of the 96 stimulation electrodes were evaluated at eight amplitudes: 20, 30, 40, 60, 70, 80, 90, and 100 μA, at 150 Hz. The subject was seated in a wheelchair approximately 1.5 meters from a TV screen. The subject was instructed to look at a fixation point in the middle of the screen throughout the experiment. In each trial, after a three-second inter-trial interval, the subject was presented with a large purple circle on the screen indicating that an electric stimulus was being delivered. Then, after a one-second delay, an auditory cue signaled the subject to report whether he felt any sensation. When a sensation was perceived, the subject reported its location on a body and hand map, with anterior and posterior views, by referencing a fine overlaying grid (Figure 1). The subject also reported qualitative characteristics including the perceived stimulus intensity, the perceived duration of stimulation, and a description of the sensation (Table 1). Sensations closer in nature to tactile stimuli were classified as cutaneous, and those triggering a feeling of movement or change in position were classified as proprioceptive. To complete the mapping of amplitude, we ran trial blocks where we randomly selected a subset of electrodes. Each block contained three replicates of stimulation per parameter, per electrode. An additional set of trials, numbering 10% of the total trials in a block, were added as ‘catch’ trials, where the visual stimuli on the screen and auditory response cue remained identical but the stimulation did not occur. Catch trials were randomly interleaved among the normal trials. In each block, trials were ordered such that stimulation did not occur to the same or adjacent electrodes concurrently. Experiment 2: For the second mapping task, five electrodes were selected for further evaluation at different amplitudes and frequencies. All the phases of the task and other stimulation parameters were the same as in the previous mapping task. The subset of electrodes selected for this task were those that exhibited the most reliable responses in the first mapping task. We varied the current amplitude (20, 40, 60, 80, 100 μA) and pulse frequency (50, 100, 150, 200, 250, 300 Hz), and tested each amplitude-frequency combination six times per electrode. The full dataset was obtained over three consecutive days. In each day, each of the five electrodes received two replicates of all possible amplitude and frequency combinations. The order of electrode stimulation was determined pseudorandomly.

Statistics and analysis methods

Throughout the analysis we used the Kruskal-Wallis nonparametric ANOVA statistical test. We calculated correlations between responses using the Pearson linear correlation coefficient. To examine whether response history had a significant effect on the proportion of reported sensations (de Lafuente and Romo, 2005), we looked at differences between the distribution of reported sensations during stimulation for three conditions: all trials, trials after a reported sensation (hit) and trials after no reported sensation (miss). We estimated these distributions for each amplitude in a given experimental session across all tested electrodes, and used Kruskal-Wallis nonparametric ANOVA with Dunn-Sidak multiple comparisons correction to test for significance at each amplitude. Furthermore, we generated a shuffle distribution of probabilities with N = 10,000 permutations for hits following a hit or a miss for each amplitude. We found no significant difference between the shuffle distributions and the empirical data, with the actual proportion being within the 5th-95th percentile range of the shuffle distribution. For the bootstrapped resampling of proprioceptive and cutaneous responses in Experiment 1, we drew 15 samples at each iteration from the total responses at each amplitude (range 21–93 responses across all amplitudes). Where normalized intensity data are reported, we rescaled the raw intensity (range 1–10) to a normalized scale (range 0–1) for each day by subtracting the minimum and then dividing by the maximum. Raw data for all analysis presented in this manuscript can be found as downloadable source data ‘Responses to single-electrode stimulation’. Specific details can also be found in the first sheet of the raw data file. In the interests of transparency, eLife includes the editorial decision letter and accompanying author responses. A lightly edited version of the letter sent to the authors after peer review is shown, indicating the most substantive concerns; minor comments are not usually included. Thank you for submitting your article "Proprioceptive and Cutaneous Sensations in Humans Elicited by Intracortical Microstimulation" for consideration by eLife. Your article has been reviewed by three peer reviewers, one of whom, Ranulfo Romo is a member of our Board of Reviewing Editors and the evaluation has been overseen by Richard Ivry as Senior Editor. The following individuals involved in review of your submission have agreed to reveal their identity: Victor de Lafuente (Reviewer #2); Apostolos P Georgopoulos (Reviewer #3). The reviewers have discussed the reviews with one another and we have worked together to draft this decision letter to help you prepare a revised submission. Summary: The reviewers found your paper contains important results for understanding the role of human somatosensory cortex and brain-machine interface. The reviewers have a number of recommendations for revision, summarized below in terms of major and minor issues. 1) It would be helpful for the authors to explore the effects of trial history on the subject's reports. Similar to de Lafuente and Romo, 2005 (Figure 3F; although we recognize that are no trials equivalent to "false alarms"), certain trial outcomes might skew the outcome probabilities in the following trial. For example, it could be the case that successful stimulation (which leads to percept formation) increases the chances of future positive reports. An analysis of this kind will help make an even more complete presentation of the results, and its absence would be noted by future readers. 2) You do not explain the results obtained by microstimulating the PMv and the SMG arrays. Did stimulation with these arrays fail to elicit any sensation? Why would that be case? Please provide a discussion on this issue. 3) Were recordings made from the implanted electrodes (we assume so)? Assuming so, we expect there would be useful information in these data, such as the number of recorded neurons, their basal activity, and how activity changed across the four weeks of the stimulation protocol. This information would be useful in future studies that extend your work. 4) The authors mention that previous ICMS protocols have elicited tingling and buzzing sensations in the patients (Introduction). What was different about the current protocol that led to the reports of more natural sensations? Summary: The reviewers found your paper contains important results for understanding the role of human somatosensory cortex and brain-machine interface. The reviewers have a number of recommendations for revision, summarized below in terms of major and minor issues. 1) It would be helpful for the authors to explore the effects of trial history on the subject's reports. Similar to de Lafuente and Romo, 2005 (Figure 3F; although we recognize that are no trials equivalent to "false alarms"), certain trial outcomes might skew the outcome probabilities in the following trial. For example, it could be the case that successful stimulation (which leads to percept formation) increases the chances of future positive reports. An analysis of this kind will help make an even more complete presentation of the results, and its absence would be noted by future readers. We examined whether a hit (response to stimulation) or a miss (no response to stimulation) altered the probability of a response in the following trial. First, we followed a method similar to de Lafuente and Romo (2005) (Figure R1A). At each amplitude, we tested for significant differences between these populations, and found a significant effect only for 30 μA. However, methodological differences could affect the above analysis. For example, in our experiments electrodes were pseudorandomly interleaved in blocks of trials, so that subsequent trials stimulated different electrodes and the number of trials between stimulation at the same electrode varied over time. In the case of the 30 μA noted above, there were fewer electrodes for which stimulation generated a response, meaning that the proportion of “hits following hits” was much lower. To address these differences, we compared the empirical probabilities of hits following a hit and hits following a miss to the same probabilities calculated from shuffling the data at each amplitude with ten thousand repetitions. We tested the difference between the shuffle distribution of response proportions and the actual proportion at each amplitude. We found the actual value to be within the 5th-95th percentile of the shuffle distribution for each amplitude (Figure R1B), and when pooling across amplitudes. These results indicate that any effect of trial history is not significantly different to chance. We have written additional text in the manuscript to present this result and updated the “Statistics and Analysis Methods” section. Results and Discussion sections: “No false positives were reported in any catch trials, and we found no effect of trial history in the proportion of reported sensations during stimulation (see Materials and methods section).” Subsection “Statistics and Analysis Methods”: “To verify whether response history had a significant effect on the proportion of reported sensations (de Lafuente and Romo, 2005), we looked at differences between the distribution of reported sensations during stimulation for three conditions: all trials, trials after a reported sensation (hit) and trials after no reported sensation (miss). We estimated these distributions for each amplitude in a given experimental session across all tested electrodes and used Kruskal-Wallis nonparametric ANOVA with Dunn-Sidak multiple comparisons correction to test for significance at each amplitude. Furthermore, we generated a shuffle distribution of probabilities with N = 10,000 permutations for hits following a hit or a miss for each amplitude. We found no significant difference between the shuffle distributions and the empirical data, with the actual proportion being within the 5th-95th percentile range of the shuffle distribution.” 2) You do not explain the results obtained by microstimulating the PMv and the SMG arrays. Did stimulation with these arrays fail to elicit any sensation? Why would that be case? Please provide a discussion on this issue. For these data, only the electrodes in somatosensory cortex were stimulated. Our experimental protocol allows for recording, but not stimulation, through the electrodes in PMV and SMG. To clarify this in the text we have added additional phrasing to several sentences: Introduction: “obtained from stimulation in S1 of a single human Subsection “Stimulation and Recording Parameters”: “delivered to a single electrode on the S1 array only.” 3) Were recordings made from the implanted electrodes (we assume so)? Assuming so, we expect there would be useful information in these data, such as the number of recorded neurons, their basal activity, and how activity changed across the four weeks of the stimulation protocol. This information would be useful in future studies that extend your work. Under our experimental protocol, we did not record from the S1 electrodes, but we did take impedance measurements at the beginning of each session. Recording to address the effects of stimulation have been made for subsequent studies, but we consider these data and experiments outside the scope of the present manuscript. 4) The authors mention that previous ICMS protocols have elicited tingling and buzzing sensations in the patients (Introduction). What was different about the current protocol that led to the reports of more natural sensations? With regards to the only other human ICMS study (Flesher et al., 2016), our protocol was similar in stimulus duration, charge balancing, leading polarity, current amplitude and pulse frequency ranges. Our protocol diverged from that study in pulse symmetry, phase duration and interphase interval, and we used a different behavioral protocol. Other factors such as array implant location, time after injury, and level of spinal cord injury vary across subjects and are likely to contribute to reported differences. Because these factors are difficult to control experimentally, our protocol, like the above-referenced study, was designed so that the subject would serve as his own control. Thus, we consider results from both of these studies valid in context and look forward to future studies investigating the relationship between these many factors and the qualitative nature of the elicited percepts.
  28 in total

1.  Areas 3a, 3b, and 1 of human primary somatosensory cortex.

Authors:  S Geyer; A Schleicher; K Zilles
Journal:  Neuroimage       Date:  1999-07       Impact factor: 6.556

2.  Sensing without touching: psychophysical performance based on cortical microstimulation.

Authors:  R Romo; A Hernández; A Zainos; C D Brody; L Lemus
Journal:  Neuron       Date:  2000-04       Impact factor: 17.173

3.  Behavioral assessment of sensitivity to intracortical microstimulation of primate somatosensory cortex.

Authors:  Sungshin Kim; Thierri Callier; Gregg A Tabot; Robert A Gaunt; Francesco V Tenore; Sliman J Bensmaia
Journal:  Proc Natl Acad Sci U S A       Date:  2015-10-26       Impact factor: 11.205

4.  Large-scale sprouting of cortical connections after peripheral injury in adult macaque monkeys.

Authors:  S L Florence; H B Taub; J H Kaas
Journal:  Science       Date:  1998-11-06       Impact factor: 47.728

5.  Neurophysiology. Decoding motor imagery from the posterior parietal cortex of a tetraplegic human.

Authors:  Tyson Aflalo; Spencer Kellis; Christian Klaes; Brian Lee; Ying Shi; Kelsie Pejsa; Kathleen Shanfield; Stephanie Hayes-Jackson; Mindy Aisen; Christi Heck; Charles Liu; Richard A Andersen
Journal:  Science       Date:  2015-05-22       Impact factor: 47.728

6.  The neural basis of perceived intensity in natural and artificial touch.

Authors:  Emily L Graczyk; Matthew A Schiefer; Hannes P Saal; Benoit P Delhaye; Sliman J Bensmaia; Dustin J Tyler
Journal:  Sci Transl Med       Date:  2016-10-26       Impact factor: 17.956

Review 7.  What, if anything, is SI? Organization of first somatosensory area of cortex.

Authors:  J H Kaas
Journal:  Physiol Rev       Date:  1983-01       Impact factor: 37.312

Review 8.  The reorganization of somatosensory cortex following peripheral nerve damage in adult and developing mammals.

Authors:  J H Kaas; M M Merzenich; H P Killackey
Journal:  Annu Rev Neurosci       Date:  1983       Impact factor: 12.449

9.  A learning-based approach to artificial sensory feedback leads to optimal integration.

Authors:  Maria C Dadarlat; Joseph E O'Doherty; Philip N Sabes
Journal:  Nat Neurosci       Date:  2014-11-24       Impact factor: 24.884

Review 10.  Restoring sensorimotor function through intracortical interfaces: progress and looming challenges.

Authors:  Sliman J Bensmaia; Lee E Miller
Journal:  Nat Rev Neurosci       Date:  2014-05       Impact factor: 34.870

View more
  50 in total

1.  Technical considerations for generating somatosensation via cortical stimulation in a closed-loop sensory/motor brain-computer interface system in humans.

Authors:  Daniel R Kramer; Spencer Kellis; Michael Barbaro; Michelle Armenta Salas; George Nune; Charles Y Liu; Richard A Andersen; Brian Lee
Journal:  J Clin Neurosci       Date:  2019-01-31       Impact factor: 1.961

2.  Utility and lower limits of frequency detection in surface electrode stimulation for somatosensory brain-computer interface in humans.

Authors:  Daniel R Kramer; Krista Lamorie-Foote; Michael Barbaro; Morgan B Lee; Terrance Peng; Angad Gogia; George Nune; Charles Y Liu; Spencer S Kellis; Brian Lee
Journal:  Neurosurg Focus       Date:  2020-02-01       Impact factor: 4.047

Review 3.  Points and lines inside human brains.

Authors:  Arturo Tozzi; James F Peters
Journal:  Cogn Neurodyn       Date:  2019-05-07       Impact factor: 5.082

4.  Short reaction times in response to multi-electrode intracortical microstimulation may provide a basis for rapid movement-related feedback.

Authors:  Joseph T Sombeck; Lee E Miller
Journal:  J Neural Eng       Date:  2019-12-17       Impact factor: 5.379

5.  Workshops of the Seventh International Brain-Computer Interface Meeting: Not Getting Lost in Translation.

Authors:  Jane E Huggins; Christoph Guger; Erik Aarnoutse; Brendan Allison; Charles W Anderson; Steven Bedrick; Walter Besio; Ricardo Chavarriaga; Jennifer L Collinger; An H Do; Christian Herff; Matthias Hohmann; Michelle Kinsella; Kyuhwa Lee; Fabien Lotte; Gernot Müller-Putz; Anton Nijholt; Elmar Pels; Betts Peters; Felix Putze; Rüdiger Rupp; Gerwin Schalk; Stephanie Scott; Michael Tangermann; Paul Tubig; Thorsten Zander
Journal:  Brain Comput Interfaces (Abingdon)       Date:  2019-12-10

Review 6.  How is electrical stimulation of the brain experienced, and how can we tell? Selected considerations on sensorimotor function and speech.

Authors:  Kevin A Mazurek; Marc H Schieber
Journal:  Cogn Neuropsychol       Date:  2019-05-10       Impact factor: 2.468

7.  Electrocorticographic changes in field potentials following natural somatosensory percepts in humans.

Authors:  Daniel R Kramer; Michael F Barbaro; Morgan Lee; Terrance Peng; George Nune; Charles Y Liu; Spencer Kellis; Brian Lee
Journal:  Exp Brain Res       Date:  2019-02-22       Impact factor: 1.972

Review 8.  Clinical neuroprosthetics: Today and tomorrow.

Authors:  Morgan B Lee; Daniel R Kramer; Terrance Peng; Michael F Barbaro; Charles Y Liu; Spencer Kellis; Brian Lee
Journal:  J Clin Neurosci       Date:  2019-07-30       Impact factor: 1.961

9.  In vivo imaging of calcium and glutamate responses to intracortical microstimulation reveals distinct temporal responses of the neuropil and somatic compartments in layer II/III neurons.

Authors:  James R Eles; Takashi D Y Kozai
Journal:  Biomaterials       Date:  2020-01-07       Impact factor: 12.479

10.  Sputtered ruthenium oxide coatings for neural stimulation and recording electrodes.

Authors:  Bitan Chakraborty; Alexandra Joshi-Imre; Jimin Maeng; Stuart F Cogan
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2020-09-17       Impact factor: 3.368

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.