Literature DB >> 29628676

Metal hypersensitivity in total hip and knee arthroplasty: Current concepts.

Samuel Akil1, Jared M Newman1, Neil V Shah1, Natasha Ahmed2, Ajit J Deshmukh3, Aditya V Maheshwari1.   

Abstract

Metal hypersensitivity (MHS) is a rare complication of total joint arthroplasty that has been linked to prosthetic device failure when other potential causes have been ruled out. The purpose of this review was to conduct an analysis of existing literature in order to get a better understanding of the pathophysiology, presentation, diagnosis, and management of MHS. It has been described as a type IV hypersensitivity reaction to the metals comprising prosthetic implants, often nickel and cobalt-chromium. Patients suffering from this condition have reported periprosthetic joint pain and swelling as well as cutaneous, eczematous dermatitis. There is no standard for diagnosis MHS, but tests such as patch testing and lymphocyte transformation testing have demonstrated utility, among others. Treatment options that have demonstrated success include administration of steroids and revision surgery, in which the existing metal implant is replaced with one of less allergenic materials. Moreover, the definitive resolution of symptoms has most commonly required revision surgery with the use of different implants. However, more studies are needed in order to understand the complexity of this subject.

Entities:  

Keywords:  Metal allergy; Metal hypersensitivity; Total hip arthroplasty; Total joint arthroplasty; Total knee arthroplasty

Year:  2017        PMID: 29628676      PMCID: PMC5884053          DOI: 10.1016/j.jcot.2017.10.003

Source DB:  PubMed          Journal:  J Clin Orthop Trauma        ISSN: 0976-5662


  36 in total

Review 1.  Hypersensitivity reactions to metallic implants - diagnostic algorithm and suggested patch test series for clinical use.

Authors:  Peter C Schalock; Torkil Menné; Jeanne D Johansen; James S Taylor; Howard I Maibach; Carola Lidén; Magnus Bruze; Jacob P Thyssen
Journal:  Contact Dermatitis       Date:  2011-09-29       Impact factor: 6.600

2.  In vitro lymphocyte proliferation as compared to patch test using gold, palladium and nickel.

Authors:  K Cederbrant; P Hultman; J A Marcusson; L Tibbling
Journal:  Int Arch Allergy Immunol       Date:  1997-03       Impact factor: 2.749

Review 3.  Metal Hypersensitivity and Total Knee Arthroplasty.

Authors:  Paul F Lachiewicz; Tyler Steven Watters; Joshua J Jacobs
Journal:  J Am Acad Orthop Surg       Date:  2016-02       Impact factor: 3.020

4.  Current modes of failure in TKA: infection, instability, and stiffness predominate.

Authors:  David H Le; Stuart B Goodman; William J Maloney; James I Huddleston
Journal:  Clin Orthop Relat Res       Date:  2014-03-11       Impact factor: 4.176

Review 5.  Metal hypersensitivity in total joint arthroplasty.

Authors:  Michelle L Pinson; Christopher A Coop; Charles N Webb
Journal:  Ann Allergy Asthma Immunol       Date:  2014-06-13       Impact factor: 6.347

6.  Metal sensitivity after TKA presenting with systemic dermatitis and hair loss.

Authors:  Zachary D Post; Fabio R Orozco; Alvin C Ong
Journal:  Orthopedics       Date:  2013-04       Impact factor: 1.390

Review 7.  Total joint arthroplasties: current concepts of patient outcomes after surgery.

Authors:  C Allyson Jones; Lauren A Beaupre; D W C Johnston; Maria E Suarez-Almazor
Journal:  Rheum Dis Clin North Am       Date:  2007-02       Impact factor: 2.670

8.  Patients with intolerance reactions to total knee replacement: combined assessment of allergy diagnostics, periprosthetic histology, and peri-implant cytokine expression pattern.

Authors:  Peter Thomas; Christine von der Helm; Christoph Schopf; Farhad Mazoochian; Lars Frommelt; Hans Gollwitzer; Josef Schneider; Michael Flaig; Veit Krenn; Benjamin Thomas; Burkhard Summer
Journal:  Biomed Res Int       Date:  2015-03-19       Impact factor: 3.411

9.  Total Knee Arthroplasty Failure Induced by Metal Hypersensitivity.

Authors:  Ryan Gupta; Duy Phan; Ran Schwarzkopf
Journal:  Am J Case Rep       Date:  2015-08-17

10.  Availability of Total Knee Arthroplasty Implants for Metal Hypersensitivity Patients.

Authors:  Sanil Harji Ajwani; Charalambos P Charalambous
Journal:  Knee Surg Relat Res       Date:  2016-12-01
View more
  12 in total

1.  A rare case of delayed hypersensitivity reaction to metal ions secondary to a remnant pedicle screw fragment after spinal arthrodesis.

Authors:  Jiha Kim
Journal:  Acta Orthop Traumatol Turc       Date:  2020-07       Impact factor: 1.511

2.  A case series of cementless revision total knee arthroplasty in patients with benzoyl peroxide allergy.

Authors:  Frank S Fröschen; Nadine Gravius; Jan-Frederic Lau; Thomas Martin Randau; Eva Kaup; Max J Friedrich; Sascha Gravius
Journal:  Int Orthop       Date:  2018-12-11       Impact factor: 3.075

3.  Early Outcomes of an Alternative Bearing Surface in Primary Total Knee Arthroplasty in Patients with Self-reported Metal Allergy.

Authors:  Jesua I Law; Micael J Morris; Jason M Hurst; Keith R Berend; Adolph V Lombardi; David A Crawford
Journal:  Arthroplast Today       Date:  2020-08-22

Review 4.  Nickel allergy to orthopaedic implants: A review and case series.

Authors:  Charles A Baumann; Brett D Crist
Journal:  J Clin Orthop Trauma       Date:  2020-02-24

5.  Diagnostic algorithm in aseptic TKA failure - What is evidence-based?

Authors:  E Röhner; M Heinecke; G Matziolis
Journal:  J Orthop       Date:  2021-03-21

6.  The Oxinium Arthrogram: A Sign of Oxidized Zirconium Implant Failure.

Authors:  Benjamin M Frye; Kelsey R Laughery; Adam E Klein
Journal:  Arthroplast Today       Date:  2021-03-07

Review 7.  Utility of Patch Testing and Lymphocyte Transformation Testing in the Evaluation of Metal Allergy in Patients with Orthopedic Implants.

Authors:  Logan J Richards; Alexandra Streifel; Jonathan M Rodrigues
Journal:  Cureus       Date:  2019-09-25

Review 8.  Metal Hypersensitivity in Joint Arthroplasty.

Authors:  Johannes Michiel van der Merwe
Journal:  J Am Acad Orthop Surg Glob Res Rev       Date:  2021-03-12

9.  A rare case of oxidized zirconium - All polyethylene tibia unicompartmental arthroplasty failure: A case report.

Authors:  Ludwig Andre Pontoh; Ismail Hadisoebroto Dilogo; Achmad Fauzi Kamal; Wahyu Widodo; Jessica Fiolin
Journal:  Int J Surg Case Rep       Date:  2022-04-05

10.  Diagnosis of Metal Hypersensitivity in Total Knee Arthroplasty: A Case Report.

Authors:  Janosch Schoon; Melanie J Ort; Katrin Huesker; Sven Geissler; Anastasia Rakow
Journal:  Front Immunol       Date:  2019-11-27       Impact factor: 7.561

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.