Literature DB >> 32554366

A rare case of delayed hypersensitivity reaction to metal ions secondary to a remnant pedicle screw fragment after spinal arthrodesis.

Jiha Kim1.   

Abstract

Delayed hypersensitivity reaction to metal ions is rare and has been mostly documented among patients undergoing total joint arthroplasty with metal-on-metal bearing surfaces. Nonetheless, to our knowledge, only a few cases associated with spinal arthrodesis have been reported in the literature. The aim of this case report was to describe the clinical features of a rare case of delayed-type hypersensitivity reaction to nickel that occurred after an extraordinarily long period of time (approximately 15 years) after spinal arthrodesis. Here, we present a 38-year-old patient who was referred to us with a diagnosis of delayed-type hypersensitivity reaction to nickel that was established by a skin patch test. The chief sign and symptoms of the patient were allergic contact dermatitis along with intractable, generalized itching that started several months ago. The medical history revealed that the patient had undergone spinal arthrodesis using rods and pedicle screws approximately 15 years ago, followed by revision surgery to remove the implants. Radiological examination showed a remnant pedicle screw fragment at the third lumbar vertebra that had broken off during the removal of implants nine years ago. However, the signs and symptoms of metal hypersensitivity started shortly before the patient was referred to our hospital. We decided to remove the screw fragment as allergic contact dermatitis was refractory to medical treatment. On postoperative day one, the itching was completely resolved, although the skin patch test remained positive.

Entities:  

Year:  2020        PMID: 32554366      PMCID: PMC7444876          DOI: 10.5152/j.aott.2020.20148

Source DB:  PubMed          Journal:  Acta Orthop Traumatol Turc        ISSN: 1017-995X            Impact factor:   1.511


  16 in total

1.  Metal hypersensitivity in patients with orthopaedic implant complications-A retrospective clinical study.

Authors:  Stefan Furrer; Kathrin Scherer Hofmeier; Leticia Grize; Andreas J Bircher
Journal:  Contact Dermatitis       Date:  2018-06-11       Impact factor: 6.600

Review 2.  Metal hypersensitivity in total hip and knee arthroplasty: Current concepts.

Authors:  Samuel Akil; Jared M Newman; Neil V Shah; Natasha Ahmed; Ajit J Deshmukh; Aditya V Maheshwari
Journal:  J Clin Orthop Trauma       Date:  2017-10-10

3.  Failure of facet replacement system with metal-on-metal bearing surface and subsequent discovery of cobalt allergy: report of 2 cases.

Authors:  Matthew L Goodwin; William Ryan Spiker; Darrel S Brodke; Brandon D Lawrence
Journal:  J Neurosurg Spine       Date:  2018-04-13

Review 4.  Bearing surfaces for total disc arthroplasty: metal-on-metal versus metal-on-polyethylene and other biomaterials.

Authors:  S Raymond Golish; Paul A Anderson
Journal:  Spine J       Date:  2011-06-22       Impact factor: 4.166

Review 5.  Metal sensitivity in patients with orthopaedic implants.

Authors:  N Hallab; K Merritt; J J Jacobs
Journal:  J Bone Joint Surg Am       Date:  2001-03       Impact factor: 5.284

6.  Delayed hypersensitivity reaction caused by metal-on-metal total disc replacement.

Authors:  Fahed Zairi; Jean Michel Remacle; Mohamed Allaoui; Richard Assaker
Journal:  J Neurosurg Spine       Date:  2013-07-05

7.  The effect of patch testing on surgical practices and outcomes in orthopedic patients with metal implants.

Authors:  Natasha Atanaskova Mesinkovska; Alejandra Tellez; Luciana Molina; Golara Honari; Apra Sood; Wael Barsoum; James S Taylor
Journal:  Arch Dermatol       Date:  2012-06

8.  Spinal implant debris-induced osteolysis.

Authors:  Nadim J Hallab; Brian W Cunningham; Joshua J Jacobs
Journal:  Spine (Phila Pa 1976)       Date:  2003-10-15       Impact factor: 3.468

Review 9.  Metal hypersensitivity in patient with posterior lumbar spine fusion: a case report and its literature review.

Authors:  Xianping Shang; Ling Wang; Depeng Kou; Xunyuan Jia; Xianglong Yang; Meng Zhang; Yilong Tang; Pengrui Wang; Shijin Wang; Yan Xu; Hong Wang
Journal:  BMC Musculoskelet Disord       Date:  2014-09-26       Impact factor: 2.362

Review 10.  Metal allergy in total-joint arthroplasty: Case report and literature review.

Authors:  Wei Bao; Yao He; Yuanjun Fan; Yueming Liao
Journal:  Medicine (Baltimore)       Date:  2018-09       Impact factor: 1.817

View more
  3 in total

1.  Metal allergy hypersensitivity after posterior thoracic spinal fusion: A case report and review of the literature.

Authors:  Harleen Saini; Andy Y Wang; Jacob J Kosarchuk; Furkan Yigitbilek; Laleh Montaser Kouhsari; Knarik Arkun; Ron I Riesenburger; Mina G Safain
Journal:  Surg Neurol Int       Date:  2021-12-30

2.  Neurological emergency from rare spinal metalloma: Case report and literature review.

Authors:  David J Mazur-Hart; Erik W Larson; Nasser K Yaghi; Aaron M Halfpenny; David R Pettersson; David A Yam
Journal:  Radiol Case Rep       Date:  2022-03-07

Review 3.  Emerging Issues Questioning the Current Treatment Strategies for Lumbar Disc Herniation.

Authors:  Zhong Y Wan; Hua Shan; Tang F Liu; Fang Song; Jun Zhang; Zhi H Liu; Kun L Ma; Hai Q Wang
Journal:  Front Surg       Date:  2022-03-28
  3 in total