Literature DB >> 29622857

Spatial Resolution and Noise Prediction in Flat-Panel Cone-Beam CT Penalized-likelihood Reconstruction.

W Wang1, G J Gang1, J H Siewerdsen1, J W Stayman1.   

Abstract

PURPOSE: Model based iterative reconstruction (MBIR) algorithms such as penalized-likelihood (PL) methods have data-dependent and shift-variant image properties. Predictors of local reconstructed noise and resolution have found application in a number of methods that seek to understand, control, and optimize CT data acquisition and reconstruction parameters in a prospective fashion (as opposed to studies based on exhaustive evaluation). However, previous MBIR prediction methods have relied on idealized system models. In this work, we develop and validate new predictors using accurate physical models specific to flat-panel CT systems.
METHODS: Novel predictors for estimation of local spatial resolution and noise properties are developed for PL reconstruction that include a physical model for blur and correlated noise in flat-panel cone-beam CT (CBCT) acquisitions. Prospective predictions (e.g., without reconstruction) of local point spread function and and local noise power spectrum (NPS) model are applied, compared, and validated using a flat-panel CBCT test bench.
RESULTS: Comparisons between prediction and physical measurements show excellent agreement for both spatial resolution and noise properties. In comparison, traditional prediction methods (that ignore blur/correlation found in flat-panel data) fail to capture important data characteristics and show significant mismatch.
CONCLUSION: Novel image property predictors permit prospective assessment of flat-panel CBCT using MBIR. Such predictors enable standard and task-based performance assessments, and are well-suited to evaluation, control, and optimization of the CT imaging chain (e.g., x-ray technique, reconstruction parameters, novel data acquisition methods, etc.) for improved imaging performance and/or dose utilization.

Entities:  

Keywords:  CT image quality; Local point spread function; image assessment; noise power spectrum

Year:  2018        PMID: 29622857      PMCID: PMC5881953          DOI: 10.1117/12.2294546

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  11 in total

1.  Regularization for uniform spatial resolution properties in penalized-likelihood image reconstruction.

Authors:  J W Stayman; J A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2000-06       Impact factor: 10.048

2.  Spatial resolution properties of penalized-likelihood image reconstruction: space-invariant tomographs.

Authors:  J A Fessler; W L Rogers
Journal:  IEEE Trans Image Process       Date:  1996       Impact factor: 10.856

3.  Mean and variance of implicitly defined biased estimators (such as penalized maximum likelihood): applications to tomography.

Authors:  J A Fessler
Journal:  IEEE Trans Image Process       Date:  1996       Impact factor: 10.856

4.  A method for measuring the presampled MTF of digital radiographic systems using an edge test device.

Authors:  E Samei; M J Flynn; D A Reimann
Journal:  Med Phys       Date:  1998-01       Impact factor: 4.071

5.  Signal, noise power spectrum, and detective quantum efficiency of indirect-detection flat-panel imagers for diagnostic radiology.

Authors:  J H Siewerdsen; L E Antonuk; Y el-Mohri; J Yorkston; W Huang; I A Cunningham
Journal:  Med Phys       Date:  1998-05       Impact factor: 4.071

6.  3D forward and back-projection for X-ray CT using separable footprints.

Authors:  Yong Long; Jeffrey A Fessler; James M Balter
Journal:  IEEE Trans Med Imaging       Date:  2010-06-07       Impact factor: 10.048

7.  Modeling and design of a cone-beam CT head scanner using task-based imaging performance optimization.

Authors:  J Xu; A Sisniega; W Zbijewski; H Dang; J W Stayman; X Wang; D H Foos; N Aygun; V E Koliatsos; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2016-03-30       Impact factor: 3.609

8.  Ordered subsets algorithms for transmission tomography.

Authors:  H Erdogan; J A Fessler
Journal:  Phys Med Biol       Date:  1999-11       Impact factor: 3.609

9.  Task-Based Regularization Design for Detection of Intracranial Hemorrhage in Cone-Beam CT.

Authors:  H Dang; J W Stayman; J Xu; A Sisniega; W Zbijewski; X Wang; D H Foos; N Aygun; V E Koliatsos; J H Siewerdsen
Journal:  Conf Proc Int Conf Image Form Xray Comput Tomogr       Date:  2016-07

10.  Task-Driven Tube Current Modulation and Regularization Design in Computed Tomography with Penalized-Likelihood Reconstruction.

Authors:  G J Gang; J H Siewerdsen; J W Stayman
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-25
View more
  1 in total

1.  Predicting image properties in penalized-likelihood reconstructions of flat-panel CBCT.

Authors:  Wenying Wang; Grace J Gang; Jeffrey H Siewerdsen; J Webster Stayman
Journal:  Med Phys       Date:  2018-11-20       Impact factor: 4.071

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.