Exradin W1 plastic scintillation detector for in vivo skin dosimetry in passive scattering proton therapy.

Fahed Alsanea1, Landon Wootton2, Narayan Sahoo1, Rajat Kudchadker1, Usama Mahmood3, Sam Beddar4.   

Abstract

In vivo skin dosimetry is desirable in passive scattering proton therapy because of the possibility of high entrance dose with a small number of fields. However, suitable detectors are needed to determine skin dose in proton therapy. Plastic scintillation detectors (PSDs) are particularly well suited for applications in proton therapy because of their water equivalence, small size, and ease of use. We investigated the utility of the Exradin W1, a commercially available PSD, for in vivo skin dosimetry during passive scattering proton therapy. We evaluated the accuracy of the Exradin W1 in six patients undergoing proton therapy for prostate cancer, as part of an Institutional Review Board-approved protocol. Over 22 weeks, we compared in vivo PSD measurements with in-phantom ionization chamber measurements and doses from the treatment planning system, resulting in 96 in vivo measurements. Temperature and ionization quenching correction factors were applied on the basis of the dose response of the PSD in a phantom. The calibrated PSD exhibited an average 7.8% under-response (±1% standard deviation) owing to ionization quenching. We observed 4% under-response at 37 °C relative to the calibration-temperature response. After temperature and quenching corrections were applied, the overall PSD dose response was within ±1% of the expected dose for all patients. The dose differences between the PSD and ionization chamber measurements for all treatment fields were within ±2% (standard deviation 0.67%). The PSD was highly accurate for in vivo skin dosimetry in passively scattered proton beams and could be useful in verifying proton therapy delivery.
Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  In vivo dosimetry; Plastic scintillation detector; Proton therapy; Skin dose

Mesh:

Substances:

Year:  2018        PMID: 29609819      PMCID: PMC5886744          DOI: 10.1016/j.ejmp.2018.02.014

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  19 in total

Review 1.  Dosimetry for ion beam radiotherapy.

Authors:  Christian P Karger; Oliver Jäkel; Hugo Palmans; Tatsuaki Kanai
Journal:  Phys Med Biol       Date:  2010-10-15       Impact factor: 3.609

Review 2.  A literature review of electronic portal imaging for radiotherapy dosimetry.

Authors:  Wouter van Elmpt; Leah McDermott; Sebastiaan Nijsten; Markus Wendling; Philippe Lambin; Ben Mijnheer
Journal:  Radiother Oncol       Date:  2008-08-14       Impact factor: 6.280

Review 3.  In vivo dosimetry in brachytherapy.

Authors:  Kari Tanderup; Sam Beddar; Claus E Andersen; Gustavo Kertzscher; Joanna E Cygler
Journal:  Med Phys       Date:  2013-07       Impact factor: 4.071

4.  Comparison of surface doses from spot scanning and passively scattered proton therapy beams.

Authors:  Bijan Arjomandy; Narayan Sahoo; James Cox; Andrew Lee; Michael Gillin
Journal:  Phys Med Biol       Date:  2009-06-23       Impact factor: 3.609

5.  Impact of physiological breathing motion for breast cancer radiotherapy with proton beam scanning - An in silico study.

Authors:  Anna M Flejmer; Behnaz Chehrazi; Dan Josefsson; Iuliana Toma-Dasu; Alexandru Dasu
Journal:  Phys Med       Date:  2017-06-09       Impact factor: 2.685

6.  Characterization of a commercial scintillation detector for 2-D dosimetry in scanned proton and carbon ion beams.

Authors:  S Russo; A Mirandola; S Molinelli; E Mastella; A Vai; G Magro; A Mairani; D Boi; M Donetti; M Ciocca
Journal:  Phys Med       Date:  2017-01-22       Impact factor: 2.685

7.  Spectroscopic study of prompt-gamma emission for range verification in proton therapy.

Authors:  Laurent Kelleter; Aleksandra Wrońska; Judith Besuglow; Adam Konefał; Karim Laihem; Johannes Leidner; Andrzej Magiera; Katia Parodi; Katarzyna Rusiecka; Achim Stahl; Thomas Tessonnier
Journal:  Phys Med       Date:  2017-01-26       Impact factor: 2.685

Review 8.  In vivo dosimetry in external beam radiotherapy.

Authors:  Ben Mijnheer; Sam Beddar; Joanna Izewska; Chester Reft
Journal:  Med Phys       Date:  2013-07       Impact factor: 4.071

9.  Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurements.

Authors:  A S Beddar; T R Mackie; F H Attix
Journal:  Phys Med Biol       Date:  1992-10       Impact factor: 3.609

10.  Protective effect of transparent film dressing on proton therapy induced skin reactions.

Authors:  Jonathan T Whaley; Maura Kirk; Keith Cengel; James McDonough; Justin Bekelman; John P Christodouleas
Journal:  Radiat Oncol       Date:  2013-01-24       Impact factor: 3.481

View more
  1 in total

1.  Dosimetric properties of a newly developed thermoluminescent sheet-type dosimeter for clinical proton beams.

Authors:  Takahiro Kato; Tatsuhiko Sagara; Shinya Komori; Ryohei Kato; Akihiko Takeuchi; Yuki Narita
Journal:  J Appl Clin Med Phys       Date:  2021-03-15       Impact factor: 2.102

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.