Literature DB >> 28131731

Spectroscopic study of prompt-gamma emission for range verification in proton therapy.

Laurent Kelleter1, Aleksandra Wrońska2, Judith Besuglow3, Adam Konefał4, Karim Laihem3, Johannes Leidner3, Andrzej Magiera5, Katia Parodi6, Katarzyna Rusiecka5, Achim Stahl3, Thomas Tessonnier7.   

Abstract

We present the results of an investigation of the prompt-gamma emission from an interaction of a proton beam with phantom materials. Measurements were conducted with a novel setup allowing the precise selection of the investigated depth in the phantom, featuring three different materials composed of carbon, oxygen and hydrogen. We studied two beam energies of 70.54 and 130.87MeV and two detection angles: 90° and 120°. The results are presented in form of profiles of the prompt-gamma yield as a function of depth. In the analysis we focused on the transitions with the largest cross sections: 12C4.44→g.s. and 16O6.13→g.s.. We compare the profiles obtained under various irradiation conditions, with emphasis on the shape of the distal fall-off. The results are also compared to calculations including different cross-section models. They are in agreement with the model exploiting published cross-section data, but the comparison with the Talys model shows discrepancies.
Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Prompt-gamma imaging; Proton therapy; Range verification

Mesh:

Year:  2017        PMID: 28131731     DOI: 10.1016/j.ejmp.2017.01.003

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  8 in total

1.  Exradin W1 plastic scintillation detector for in vivo skin dosimetry in passive scattering proton therapy.

Authors:  Fahed Alsanea; Landon Wootton; Narayan Sahoo; Rajat Kudchadker; Usama Mahmood; Sam Beddar
Journal:  Phys Med       Date:  2018-02-27       Impact factor: 2.685

2.  MC safe bunker designing for an 18 MV linac with nanoparticles included primary barriers and effect of the nanoparticles on the shielding aspects.

Authors:  Amir Ghasemi-Jangjoo; Hosein Ghiasi
Journal:  Rep Pract Oncol Radiother       Date:  2019-06-06

3.  Application of the phase-space distribution approach of Monte Carlo for radiation contamination dose estimation from the (n,γ), (γ,n) nuclear reactions and linac leakage photons in the megavoltage radiotherapy facility.

Authors:  Amir Ghasemi-Jangjoo; Hosein Ghiasi
Journal:  Rep Pract Oncol Radiother       Date:  2020-01-24

4.  Precision imaging of 4.4 MeV gamma rays using a 3-D position sensitive Compton camera.

Authors:  Ayako Koide; Jun Kataoka; Takamitsu Masuda; Saku Mochizuki; Takanori Taya; Koki Sueoka; Leo Tagawa; Kazuya Fujieda; Takuya Maruhashi; Takuya Kurihara; Taku Inaniwa
Journal:  Sci Rep       Date:  2018-05-25       Impact factor: 4.379

5.  Proton range verification with MACACO II Compton camera enhanced by a neural network for event selection.

Authors:  Enrique Muñoz; Ana Ros; Marina Borja-Lloret; John Barrio; Peter Dendooven; Josep F Oliver; Ikechi Ozoemelam; Jorge Roser; Gabriela Llosá
Journal:  Sci Rep       Date:  2021-04-29       Impact factor: 4.379

6.  Detection and discrimination of neutron capture events for NCEPT dose quantification.

Authors:  Andrew Chacon; Marissa Kielly; Harley Rutherford; Daniel R Franklin; Anita Caracciolo; Luca Buonanno; Ilenia D'Adda; Anatoly Rosenfeld; Susanna Guatelli; Marco Carminati; Carlo Fiorini; Mitra Safavi-Naeini
Journal:  Sci Rep       Date:  2022-04-07       Impact factor: 4.996

7.  PIBS: Proton and ion beam spectroscopy for in vivo measurements of oxygen, carbon, and calcium concentrations in the human body.

Authors:  Paulo Magalhaes Martins; Riccardo Dal Bello; Benjamin Ackermann; Stephan Brons; German Hermann; Thomas Kihm; Joao Seco
Journal:  Sci Rep       Date:  2020-04-24       Impact factor: 4.379

8.  Towards real-time PGS range monitoring in proton therapy of prostate cancer.

Authors:  Paulo Magalhaes Martins; Hugo Freitas; Thomas Tessonnier; Benjamin Ackermann; Stephan Brons; Joao Seco
Journal:  Sci Rep       Date:  2021-07-28       Impact factor: 4.379

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.