Literature DB >> 29588795

Impact of Intravascular Ultrasound in Clinical Practice.

Andres Vasquez1, Neville Mistry1, Jasvindar Singh1.   

Abstract

Intravascular ultrasound (IVUS) has expanded our understanding of atherosclerotic plaque morphology, and provides an opportunity to guide cardiovascular interventions and evaluate results. Use of this technique requires understanding of ultrasound physics, catheter differences, skills in vessel, plaque and stent quantification and knowledge of artifacts and various physiologic and pathologic findings. Optimal cardiovascular interventions should result in absence of inflow or outflow obstruction, precise geographic landing, while attaining the largest feasible luminal gain without plaque protrusion, vessel dissection or perforation and, if deployed, with complete stent expansion and apposition to the vessel wall. IVUS is safe, cost efficient and effectively optimises cardiovascular interventions. In addition, IVUS improves outcomes when used to guide coronary interventions using bare metal stents (BMS) and drug eluting stents (DES). The role of IVUS in endovascular therapy is rapidly expanding. This review will focus on the impact of IVUS in clinical practice.

Entities:  

Keywords:  Coronary artery disease; Intravascular ultrasonography; percutaneous coronary intervention

Year:  2014        PMID: 29588795      PMCID: PMC5808501          DOI: 10.15420/icr.2014.9.3.156

Source DB:  PubMed          Journal:  Interv Cardiol        ISSN: 1756-1485


  70 in total

1.  Coronary plaque classification with intravascular ultrasound radiofrequency data analysis.

Authors:  Anuja Nair; Barry D Kuban; E Murat Tuzcu; Paul Schoenhagen; Steven E Nissen; D Geoffrey Vince
Journal:  Circulation       Date:  2002-10-22       Impact factor: 29.690

2.  Intravascular ultrasound-guided balloon angioplasty compared with stent: immediate and 6-month results of the multicenter, randomized Balloon Equivalent to Stent Study (BEST).

Authors:  François Schiele; Nicolas Meneveau; Martine Gilard; Jacques Boschat; Philippe Commeau; Liu Pin Ming; Pradip Sewoke; Marie-France Seronde; Mariette Mercier; Sanjiv Gupta; Jean-Pierre Bassand
Journal:  Circulation       Date:  2003-02-04       Impact factor: 29.690

3.  Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: an intravascular ultrasound study.

Authors:  Kenichi Fujii; Stéphane G Carlier; Gary S Mintz; Yi-ming Yang; Issam Moussa; Giora Weisz; George Dangas; Roxana Mehran; Alexandra J Lansky; Edward M Kreps; Michael Collins; Gregg W Stone; Jeffrey W Moses; Martin B Leon
Journal:  J Am Coll Cardiol       Date:  2005-04-05       Impact factor: 24.094

4.  The accuracy of length measurements using different intravascular ultrasound motorized transducer pullback systems.

Authors:  Kaoru Tanaka; Stéphane G Carlier; Gary S Mintz; Koichi Sano; Xuebo Liu; Kenichi Fujii; Jose de Ribamar Costa; Joanna Lui; Jeffrey W Moses; Gregg W Stone; Martin B Leon
Journal:  Int J Cardiovasc Imaging       Date:  2007-03-17       Impact factor: 2.357

5.  Impact of intravascular ultrasound on the long-term clinical outcomes in the treatment of coronary ostial lesions.

Authors:  Yogesh Patel; Jeremiah P Depta; Jayendrakumar S Patel; Shriti K Masrani; Eric Novak; Alan Zajarias; Howard I Kurz; John M Lasala; Richard G Bach; Jasvindar Singh
Journal:  Catheter Cardiovasc Interv       Date:  2015-11-27       Impact factor: 2.692

6.  Safety of intracoronary ultrasound: data from a Multicenter European Registry.

Authors:  B W Batkoff; D T Linker
Journal:  Cathet Cardiovasc Diagn       Date:  1996-07

7.  Patterns of calcification in coronary artery disease. A statistical analysis of intravascular ultrasound and coronary angiography in 1155 lesions.

Authors:  G S Mintz; J J Popma; A D Pichard; K M Kent; L F Satler; Y C Chuang; C J Ditrano; M B Leon
Journal:  Circulation       Date:  1995-04-01       Impact factor: 29.690

8.  Intravascular ultrasound assessment of drug-eluting stent expansion.

Authors:  Jose de Ribamar Costa; Gary S Mintz; Stéphane G Carlier; Kenichi Fujii; Koichi Sano; Masashi Kimura; Kaoru Tanaka; Ricardo A Costa; Joanna Lui; Yingbo Na; Celia Castellanos; Sinan Biro; Issam Moussa; Gregg W Stone; Jeffrey W Moses; Martin B Leon
Journal:  Am Heart J       Date:  2007-02       Impact factor: 4.749

9.  Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: serial intravascular ultrasound analysis from the sirius trial.

Authors:  Shinjo Sonoda; Yoshihiro Morino; Junya Ako; Mitsuyasu Terashima; Ali H M Hassan; Heidi N Bonneau; Martin B Leon; Jeffrey W Moses; Paul G Yock; Yasuhiro Honda; Richard E Kuntz; Peter J Fitzgerald
Journal:  J Am Coll Cardiol       Date:  2004-06-02       Impact factor: 24.094

10.  Stent implantation for chronic total occlusion in the iliac artery using intravascular ultrasound-guided carbon dioxide angiography without iodinated contrast medium.

Authors:  Akihiro Higashimori; Yoshiaki Yokoi
Journal:  Cardiovasc Interv Ther       Date:  2013-05-03
View more
  3 in total

1.  Assessment of the healing process after percutaneous implantation of a cardiovascular device: a systematic review.

Authors:  Elodie Perdreau; Zakaria Jalal; Richard D Walton; Jérôme Naulin; Julie Magat; Bruno Quesson; Hubert Cochet; Olivier Bernus; Jean-Benoît Thambo
Journal:  Int J Cardiovasc Imaging       Date:  2019-11-19       Impact factor: 2.357

Review 2.  Current and Future Applications of Artificial Intelligence in Coronary Artery Disease.

Authors:  Nitesh Gautam; Prachi Saluja; Abdallah Malkawi; Mark G Rabbat; Mouaz H Al-Mallah; Gianluca Pontone; Yiye Zhang; Benjamin C Lee; Subhi J Al'Aref
Journal:  Healthcare (Basel)       Date:  2022-01-26

Review 3.  Mechanically Rotating Intravascular Ultrasound (IVUS) Transducer: A Review.

Authors:  Jin-Ho Sung; Jin-Ho Chang
Journal:  Sensors (Basel)       Date:  2021-06-05       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.