Time-gated scintillator imaging for real-time optical surface dosimetry in total skin electron therapy.

Petr Bruza1, Sarah L Gollub, Jacqueline M Andreozzi, Irwin I Tendler, Benjamin B Williams, Lesley A Jarvis, David J Gladstone, Brian W Pogue.   

Abstract

The purpose of this study was to measure surface dose by remote time-gated imaging of plastic scintillators. A novel technique for time-gated, intensified camera imaging of scintillator emission was demonstrated, and key parameters influencing the signal were analyzed, including distance, angle and thickness. A set of scintillator samples was calibrated by using thermo-luminescence detector response as reference. Examples of use in total skin electron therapy are described. The data showed excellent room light rejection (signal-to-noise ratio of scintillation SNR  ≈  470), ideal scintillation dose response linearity, and 2% dose rate error. Individual sample scintillation response varied by 7% due to sample preparation. Inverse square distance dependence correction and lens throughput error (8% per meter) correction were needed. At scintillator-to-source angle and observation angle  <50°, the radiant energy fluence error was smaller than 1%. The achieved standard error of the scintillator cumulative dose measurement compared to the TLD dose was 5%. The results from this proof-of-concept study documented the first use of small scintillator targets for remote surface dosimetry in ambient room lighting. The measured dose accuracy renders our method to be comparable to thermo-luminescent detector dosimetry, with the ultimate realization of accuracy likely to be better than shown here. Once optimized, this approach to remote dosimetry may substantially reduce the time and effort required for surface dosimetry.

Entities:  

Mesh:

Year:  2018        PMID: 29588437      PMCID: PMC6233889          DOI: 10.1088/1361-6560/aaba19

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

1.  Investigation of the use of MOSFET for clinical IMRT dosimetric verification.

Authors:  Cynthia F Chuang; Lynn J Verhey; Ping Xia
Journal:  Med Phys       Date:  2002-06       Impact factor: 4.071

2.  Total skin electron irradiation: evaluation of dose uniformity throughout the skin surface.

Authors:  Yavuz Anacak; Zumre Arican; Raquel Bar-Deroma; Ada Tamir; Abraham Kuten
Journal:  Med Dosim       Date:  2003       Impact factor: 1.482

3.  Comparison of p-type commercial electron diodes for in vivo dosimetry.

Authors:  D Marre; G Marinello
Journal:  Med Phys       Date:  2004-01       Impact factor: 4.071

4.  Real-time in vivo Cherenkoscopy imaging during external beam radiation therapy.

Authors:  Rongxiao Zhang; David J Gladstone; Lesley A Jarvis; Rendall R Strawbridge; P Jack Hoopes; Oscar D Friedman; Adam K Glaser; Brian W Pogue
Journal:  J Biomed Opt       Date:  2013-11       Impact factor: 3.170

5.  Optical dosimetry of radiotherapy beams using Cherenkov radiation: the relationship between light emission and dose.

Authors:  Adam K Glaser; Rongxiao Zhang; David J Gladstone; Brian W Pogue
Journal:  Phys Med Biol       Date:  2014-06-18       Impact factor: 3.609

Review 6.  Review of the results of the in vivo dosimetry during total skin electron beam therapy.

Authors:  Gabriele Guidi; Giovanni Gottardi; Paola Ceroni; Tiziana Costi
Journal:  Rep Pract Oncol Radiother       Date:  2013-08-15

7.  Early experience in using and 18 Me V linear accelerator for mycosis fungoides at Howard University Hospital.

Authors:  P P Kumar; K Henschke; K P Mandal; J R Nibhanupudy; I S Patel
Journal:  J Natl Med Assoc       Date:  1977-04-01       Impact factor: 1.798

8.  Alanine/EPR dosimetry applied to the verification of a total body irradiation protocol and treatment planning dose calculation using a humanoid phantom.

Authors:  B Schaeken; S Lelie; P Meijnders; D Van den Weyngaert; H Janssens; D Verellen
Journal:  Med Phys       Date:  2010-12       Impact factor: 4.071

9.  Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurements.

Authors:  A S Beddar; T R Mackie; F H Attix
Journal:  Phys Med Biol       Date:  1992-10       Impact factor: 3.609

10.  Cherenkov imaging method for rapid optimization of clinical treatment geometry in total skin electron beam therapy.

Authors:  Jacqueline M Andreozzi; Rongxiao Zhang; David J Gladstone; Benjamin B Williams; Adam K Glaser; Brian W Pogue; Lesley A Jarvis
Journal:  Med Phys       Date:  2016-02       Impact factor: 4.071

  10 in total
  6 in total

1.  Imaging luminescent tattoo inks for direct visualization of linac and cobalt irradiation.

Authors:  Ethan P M LaRochelle; Jennifer Soter; Leonardo Barrios; Marysia Guzmán; Samuel S Streeter; Jason R Gunn; Suyapa Bejarano; Brian W Pogue
Journal:  Med Phys       Date:  2020-03-05       Impact factor: 4.071

2.  Direct in-water radiation dose measurements using Cherenkov emission corrected signals from polarization imaging for a clinical radiotherapy application.

Authors:  Émily Cloutier; Luc Beaulieu; Louis Archambault
Journal:  Sci Rep       Date:  2022-06-10       Impact factor: 4.996

3.  Optical imaging method to quantify spatial dose variation due to the electron return effect in an MR-linac.

Authors:  Jacqueline M Andreozzi; Petr Brůža; Jochen Cammin; Brian W Pogue; David J Gladstone; Olga Green
Journal:  Med Phys       Date:  2019-12-25       Impact factor: 4.071

4.  Assessment of imaging Cherenkov and scintillation signals in head and neck radiotherapy.

Authors:  Daniel A Alexander; Irwin I Tendler; Petr Bruza; Xu Cao; Philip E Schaner; Bethany S Marshall; Lesley A Jarvis; David J Gladstone; Brian W Pogue
Journal:  Phys Med Biol       Date:  2019-07-18       Impact factor: 3.609

5.  Technical Note: A novel dosimeter improves total skin electron therapy surface dosimetry workflow.

Authors:  Irwin I Tendler; Petr Bruza; Michael Jermyn; Jennifer Soter; Gregory Sharp; Benjamin Williams; Lesley A Jarvis; Brian Pogue; David J Gladstone
Journal:  J Appl Clin Med Phys       Date:  2020-04-19       Impact factor: 2.102

6.  Improvements to an optical scintillator imaging-based tissue dosimetry system.

Authors:  Irwin I Tendler; Petr Bruza; Michael Jermyn; Antoine Fleury; Benjamin B Williams; Lesley A Jarvis; Brian W Pogue; David J Gladstone
Journal:  J Biomed Opt       Date:  2019-07       Impact factor: 3.170

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.