Literature DB >> 24938928

Optical dosimetry of radiotherapy beams using Cherenkov radiation: the relationship between light emission and dose.

Adam K Glaser1, Rongxiao Zhang, David J Gladstone, Brian W Pogue.   

Abstract

Recent studies have proposed that light emitted by the Cherenkov effect may be used for a number of radiation therapy dosimetry applications. There is a correlation between the captured light and expected dose under certain conditions, yet discrepancies have also been observed and a complete examination of the theoretical differences has not been done. In this study, a fundamental comparison between the Cherenkov emission and absorbed dose was explored for x-ray photons, electrons, and protons using both a theoretical and Monte Carlo-based analysis. Based on the findings of where dose correlates with Cherenkov emission, it was concluded that for x-ray photons the light emission would be optimally suited for narrow beam stereotactic radiation therapy and surgery validation studies, for verification of dynamic intensity-modulated and volumetric modulated arc therapy treatment plans in water tanks, near monoenergetic sources (e.g., Co-60 and brachy therapy sources) and also for entrance and exit surface imaging dosimetry of both narrow and broad beams. For electron use, Cherenkov emission was found to be only suitable for surface dosimetry applications. Finally, for proton dosimetry, there exists a fundamental lack of Cherenkov emission at the Bragg peak, making the technique of little use, although post-irradiation detection of light emission from radioisotopes could prove to be useful.

Mesh:

Substances:

Year:  2014        PMID: 24938928     DOI: 10.1088/0031-9155/59/14/3789

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  31 in total

1.  Review of biomedical Čerenkov luminescence imaging applications.

Authors:  Kaveh Tanha; Ali Mahmoud Pashazadeh; Brian W Pogue
Journal:  Biomed Opt Express       Date:  2015-07-28       Impact factor: 3.732

2.  Optical cone beam tomography of Cherenkov-mediated signals for fast 3D dosimetry of x-ray photon beams in water.

Authors:  Adam K Glaser; Jacqueline M Andreozzi; Rongxiao Zhang; Brian W Pogue; David J Gladstone
Journal:  Med Phys       Date:  2015-07       Impact factor: 4.071

Review 3.  Optical and x-ray technology synergies enabling diagnostic and therapeutic applications in medicine.

Authors:  Brian W Pogue; Brian C Wilson
Journal:  J Biomed Opt       Date:  2018-10       Impact factor: 3.170

4.  Real-time Cherenkov emission portal imaging during CyberKnife® radiotherapy.

Authors:  Yiannis Roussakis; Rongxiao Zhang; Geoff Heyes; Gareth Webster; Suzannah Mason; Stuart Green; Brian Pogue; Hamid Dehghani
Journal:  Phys Med Biol       Date:  2015-10-29       Impact factor: 3.609

Review 5.  Radioluminescence in biomedicine: physics, applications, and models.

Authors:  Justin S Klein; Conroy Sun; Guillem Pratx
Journal:  Phys Med Biol       Date:  2019-02-06       Impact factor: 3.609

6.  Passively scattered proton beam entrance dosimetry with a plastic scintillation detector.

Authors:  Landon Wootton; Charles Holmes; Narayan Sahoo; Sam Beddar
Journal:  Phys Med Biol       Date:  2015-01-15       Impact factor: 3.609

7.  In Reply to Pratx and Kapp.

Authors:  Mark Oldham; Suk W Yoon; Justus Adamson; Xiaofeng Zhang; Peter Fecci; Mark Dewhirst
Journal:  Int J Radiat Oncol Biol Phys       Date:  2018-06-01       Impact factor: 7.038

8.  Signal intensity analysis and optimization for in vivo imaging of Cherenkov and excited luminescence.

Authors:  Ethan P M LaRochelle; Jennifer R Shell; Jason R Gunn; Scott C Davis; Brian W Pogue
Journal:  Phys Med Biol       Date:  2018-04-20       Impact factor: 3.609

9.  Beam and tissue factors affecting Cherenkov image intensity for quantitative entrance and exit dosimetry on human tissue.

Authors:  Rongxiao Zhang; Adam K Glaser; Jacqueline Andreozzi; Shudong Jiang; Lesley A Jarvis; David J Gladstone; Brian W Pogue
Journal:  J Biophotonics       Date:  2016-08-10       Impact factor: 3.207

10.  Time-gated scintillator imaging for real-time optical surface dosimetry in total skin electron therapy.

Authors:  Petr Bruza; Sarah L Gollub; Jacqueline M Andreozzi; Irwin I Tendler; Benjamin B Williams; Lesley A Jarvis; David J Gladstone; Brian W Pogue
Journal:  Phys Med Biol       Date:  2018-05-02       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.