| Literature DB >> 29563760 |
Richard Lord1, Nicholas E Burr1, Noor Mohammed1, Venkataraman Subramanian2.
Abstract
AIM: To perform a systematic review and meta-analysis for the diagnostic accuracy of in vivo lesion characterization in colonic inflammatory bowel disease (IBD), using optical imaging techniques, including virtual chromoendoscopy (VCE), dye-based chromoendoscopy (DBC), magnification endoscopy and confocal laser endomicroscopy (CLE).Entities:
Keywords: Confocal laser endomicroscopy; Fujinon intelligence chromoendoscopy; I-scan; Inflammatory bowel disease dysplasia; Lesion characterization; Narrow band imaging
Mesh:
Year: 2018 PMID: 29563760 PMCID: PMC5850135 DOI: 10.3748/wjg.v24.i10.1167
Source DB: PubMed Journal: World J Gastroenterol ISSN: 1007-9327 Impact factor: 5.742
Figure 1Study flow chart for studies eventually included into the meta-analysis. IBD: Inflammatory bowel disease.
Study characteristics
| Virtual Chromoendoscopy | |||||||||
| Cassinotti et al[ | 2016 | Abstract | i-scan HD | / | Single centre/prospective cohort | Real time | 40 | 287 | Kudo PP + other endoscopic features |
| Prospective cohort | |||||||||
| Efthymiou et al[ | 2013 | Article | NBI HD | 2 | Single centre/prospective cohort | Real time | 44 | 121 | Kudo PP + low level magnification |
| Van den broek et al[ | 2011 | Article | NBI HD | 4 | Single centre/randomized cross-over | Real time | 48 | 153 | Kudo PP |
| Cassinotti et al[ | 2015 | Abstract | FICE HD | 1 | Single centre/randomized parallel | Real time | 41 | 261 | Kudo PP |
| Cassinotti et al[ | 2015 | Abstract | FICE HD | 1 | Single centre/prospective cohort | Real time | 59 | 205 | Kudo PP |
| Dye-based Chromoendoscopy | |||||||||
| Carballal et al[ | 2016 | Article | IC 0.4% SD/HD | 15 | Multi-centre/prospective cohort | Real time | 350 | 595 | Kudo PP + 10 other items |
| 2016 | Abstract | MB 0.1% HD | / | Prospective cohort | Real time | 22 | 21 | / | |
| 2016 | Article | MB 0.1% SD | > 1 | Multi-centre/prospective cohort | Real time | 61 | 66 | Kudo PP | |
| Munoz et al [ | 2016 | Abstract | IC 0.2%-0.4% HD | > 1 | Multi-centre/retrospective cohort | Real time | 243 | 953 | Kudo PP |
| Wanders et al[ | 2015 | Article | MB 0.1% or IC 0.3% | 17 | Multi-centre/retrospective questionnaire | Image review | / | 30 | / |
| 2011 | Article | IC 0.4% SD | 2 | Single centre/prospective cohort | Real time | 30 | 100 | Kudo PP | |
| Confocal Laser Endomicroscopy | |||||||||
| 2016 | Article | iCLE | > 1 | Multi-centre/prospective cohort | Real time | 61 | 60 | Mainz criteria | |
| Dlugosz et al[ | 2016 | Article | pCLE | 1 endoscopist (2 reviewed images) | Single centre/retrospective cohort | Image review | 69 | 644 | Crypt + vessel architecture |
| 2016 | Abstract | pCLE | / | Prospective cohort | Real time | 22 | 20 | Miami classification | |
| Freire et al[ | 2014 | Article | iCLE | 1 | Single centre/randomized trial | Real time | 72 | 104 | Mainz criteria |
| Rispo et al[ | 2012 | Article | pCLE | 1 | Single centre/prospective cohort | Real time | 51 | 15 | De Palma classification |
| Shahid et al[ | 2011 | Abstract | pCLE | 3 reviewed images | Single centre/retrospective cohort | Image review | 25 | 61 | / |
| 2011 | Article | iCLE | 2 | Single centre/prospective cohort | Real time | 30 | 68 | Mainz classification | |
| 2011 | Article | pCLE | 4 endoscopists (2 reviewing images) | Single centre/retrospective cohort | Image review | 22 | 48 | Crypt + vessel architecture | |
| Keisslich et al[ | 2007 | Article | iCLE | / | Single centre/randomized trial | Real time | 80 | 134 | Mainz classification |
| Magnification endoscopy | |||||||||
| Nishiyama et al[ | 2016 | Article | NBI | 5 reviewed images | Single centre/retrospective cohort | Image review | 27 | 33 | Surface + vessel patterns |
| 2011 | Article | NBI | 4 | Single centre/prospective cohort | Real time | 22 | 48 | Kudo PP + vascular patterns | |
| Van den broek et al[ | 2008 | Article | NBI | 3 | Single centre/randomized trial | Real time | 50 | 98 | Kudo PP |
| Matsumoto et al[ | 2007 | Article | NBI | 1 | Single centre/prospective cohort | Real time | 46 | 296 | Surface structure |
| Keisslich et al[ | 2003 | Article | MB 0.1% | 1 | Single centre/randomized trial | Real time | 84 | 118 | Kudo PP |
| Studies using combined technologies | |||||||||
| Bisschops et al[ | 2013 | Abstract | Dye-based chromo/NBI | 10 reviewed images | Multi-centre / Retrospective cohort | Image review | 27 | 50 | Kudo PP |
List of studies included in meta-analysis and displayed according to technology type. PP: Pit pattern; /: Data missing.
Two different technologies from same abstract;
Two different technologies from same article;
Two different technologies from same article;
Two different technologies from the same article.
Figure 2Stacked bar charts showing proportion of studies with low, high or unclear risks of bias. Vertical axis represents the four domains of the quality assessment of diagnostic accuracy studies 2.
Figure 3Stacked bar charts showing proportion of studies with low, high or unclear applicability. Vertical axis represents the three domains of the quality assessment of diagnostic accuracy studies 2.
quality assessment of diagnostic accuracy studies 2 for each study
| DOMAIN 1 | ||||||||||||||||||||||
| Patient selection | ||||||||||||||||||||||
| Risk of bias | ||||||||||||||||||||||
| Could selection of patients introduced bias? | L | L | L | L | L | L | U | L | L | H | U | L | L | L | H | H | L | H | L | L | L | H |
| Concerns regarding applicability | ||||||||||||||||||||||
| Concern included patients don’t match review question? | L | L | L | L | L | L | L | L | L | L | L | L | L | L | L | L | L | L | L | L | L | L |
| DOMAIN 2 | ||||||||||||||||||||||
| Index test | ||||||||||||||||||||||
| Risk of bias | ||||||||||||||||||||||
| Conduct or interpretation of index test introduced bias? | L | L | L | L | L | L | L | L | U | H | H | H | L | L | H | H | L | H | L | L | L | H |
| Concerns regarding applicability | ||||||||||||||||||||||
| Concern index test, its conduct or interpretation differs from review question? | L | L | L | L | L | L | L | L | L | L | L | L | L | L | L | L | L | L | L | L | L | L |
| DOMAIN 3 | ||||||||||||||||||||||
| Reference standard | ||||||||||||||||||||||
| Risk of bias | ||||||||||||||||||||||
| Could reference standard, conduct or interpretation have introduced bias? | U | U | L | U | U | U | U | L | U | U | L | L | L | L | U | L | L | U | L | L | L | U |
| Concerns regarding applicability | ||||||||||||||||||||||
| Concern target condition as defined by reference standard not match review question? | L | L | L | L | L | L | L | L | L | L | L | L | L | L | L | L | L | L | L | L | L | L |
| DOMAIN 4 | ||||||||||||||||||||||
| Flow and timing | ||||||||||||||||||||||
| Risk of bias | ||||||||||||||||||||||
| Could patient flow introduced bias? | U | L | H | U | U | L | U | L | U | H | H | U | L | L | H | H | L | H | L | L | L | H |
L: Low risk; H: High risk; U: Unclear.
Accuracy of the different technologies
| All | |||||||
| VCE | 5 | 0.86 (0.62-0.95) | 0.87 (0.72-0.95) | 6.7 (2.6-17.8) | 0.17 (0.05-0.53) | 41 (6-297) | 0.93 (0.90-0.95) |
| DBC | 6 | 0.67 (0.44-0.84) | 0.86 (0.72-0.94) | 4.9 (2.1-11.3) | 0.38 (0.20-0.73) | 13 (3-48) | 0.84 (0.81-0.87) |
| Magnification | 5 | 0.90 (0.77-0.96) | 0.87 (0.81-0.91) | 7.0 (4.6-10.7) | 0.11 (0.05-0.28) | 62 (18-209) | 0.93 (0.91-0.95) |
| CLE | 9 | 0.87 (0.71-0.95) | 0.94 (0.87-0.97) | 14.0 (6.1-32.4) | 0.14 (0.06-0.33) | 101 (23-442) | 0.96 (0.94-0.97) |
| Real-time | |||||||
| Kudo PP | 10 | 0.78 (0.57-0.91) | 0.89 (0.80-0.94) | 6.9 (3.5-13.5) | 0.24 (0.11-0.55) | 28 (7-110) | 0.91 (0.89-0.94) |
| CLE | 6 | 0.91 (0.66-0.98) | 0.97 (0.94-0.98) | 28.4 (13.6-59.1) | 0.09 (0.02-0.43) | 322 (41-2529) | 0.98 (0.97-0.99) |
| All Kudo PP | 12 | 0.78 (0.61-0.88) | 0.86 (0.76-0.92) | 5.5 (2.9-10.1) | 0.26 (0.14-0.50) | 21 (7-66) | 0.89 (0.86-0.92) |
All using both real-time and image based studies for the different technologies. Real-time, sub-group analysis with studies using only real time Kudo pit pattern (both VCE and DBC) and real-time CLE. All Kudo PP includes all studies using Kudo pit pattern (real-time and image-based). VCE: Virtual chromoendoscopy; DBC: Dye-based chromoendoscopy; CLE: Confocal laser endomicroscopy; Kudo PP: Kudo pit pattern; LHR+: Positive likelihood ratios; LHR-: Negative likelihood ratios; DOR: Diagnostic odd ratios.
Figure 4Forest plot for real-time Kudo pit pattern (A), and forest plot for real-time confocal laser endomicroscopy (B).
Figure 5Area under SROC curve for real-time Kudo pit pattern (A) and area under SROC curve for real-time confocal laser endomicroscopy (B).
Figure 6Funnel plot with superimposed regression line looking for publication bias.