Literature DB >> 29541514

Ultrahigh-speed line-scan SD-OCT for four-dimensional in vivo imaging of small animal models.

Zaineb Al-Qazwini1, Zhen Yu Gordon Ko1, Kalpesh Mehta1, Nanguang Chen1.   

Abstract

We report an ultrahigh-speed and high-resolution line-scan spectral-domain optical coherence tomography (SD-OCT) system that integrates a number of mechanisms for improving image quality. The illumination uniformity is significantly improved by the use of a Powell lens; Phase stepping and differential reconstruction are combined to suppress autocorrelation artifacts; Nonlocal means (NLM) is employed to enhance the signal to noise ratio while minimizing motion artifacts. The system is capable of acquiring cross-sectional images at more than 3,500 B-scans per second with sensitivities between 70dB and 90dB. The high B-scan rate enables image post-processing with nonlocal means, an advanced noise reduction algorithm that affords enhanced morphological details and reduced motion artifacts. The achieved axial and lateral resolutions are 2.0 and 6.2 microns, respectively. We have used this system to acquire four-dimensional (three-dimensional space and one-dimensional time) imaging data from live chicken embryos at up to 40 volumes per second. Dynamic cardiac tissue deformation and blood flow could be clearly visualized at high temporal and spatial resolutions, providing valuable information for understanding the mechanical and fluid dynamic properties of the developing cardiac system.

Entities:  

Keywords:  (110.0180) Microscopy; (110.4500) Optical coherence tomography; (120.4570) Optical design of instruments; (170.3880) Medical and biological imaging

Year:  2018        PMID: 29541514      PMCID: PMC5846524          DOI: 10.1364/BOE.9.001216

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  35 in total

1.  Stress-strain relations in embryonic chick heart.

Authors:  L A Taber; R Perucchio
Journal:  Am J Physiol Heart Circ Physiol       Date:  2001-07       Impact factor: 4.733

2.  In vivo human retinal imaging by Fourier domain optical coherence tomography.

Authors:  Maciej Wojtkowski; Rainer Leitgeb; Andrzej Kowalczyk; Tomasz Bajraszewski; Adolf F Fercher
Journal:  J Biomed Opt       Date:  2002-07       Impact factor: 3.170

3.  Multi-megahertz OCT: High quality 3D imaging at 20 million A-scans and 4.5 GVoxels per second.

Authors:  Wolfgang Wieser; Benjamin R Biedermann; Thomas Klein; Christoph M Eigenwillig; Robert Huber
Journal:  Opt Express       Date:  2010-07-05       Impact factor: 3.894

4.  Parallel Fourier domain optical coherence tomography for in vivo measurement of the human eye.

Authors:  Branislav Grajciar; Michael Pircher; Adolf Fercher; Rainer Leitgeb
Journal:  Opt Express       Date:  2005-02-21       Impact factor: 3.894

5.  Spatially resolved spectral interferometry for determination of subsurface structure.

Authors:  A F Zuluaga; R Richards-Kortum
Journal:  Opt Lett       Date:  1999-04-15       Impact factor: 3.776

6.  High-speed optical coherence tomography imaging of the beating avian embryonic heart.

Authors:  Shi Gu; Michael W Jenkins; Michiko Watanabe; Andrew M Rollins
Journal:  Cold Spring Harb Protoc       Date:  2011-02-01

7.  Line-field parallel swept source MHz OCT for structural and functional retinal imaging.

Authors:  Daniel J Fechtig; Branislav Grajciar; Tilman Schmoll; Cedric Blatter; Rene M Werkmeister; Wolfgang Drexler; Rainer A Leitgeb
Journal:  Biomed Opt Express       Date:  2015-02-04       Impact factor: 3.732

8.  A series of normal stages in the development of the chick embryo.

Authors:  V HAMBURGER; H L HAMILTON
Journal:  J Morphol       Date:  1951-01       Impact factor: 1.804

9.  Changes in activation sequence of embryonic chick atria correlate with developing myocardial architecture.

Authors:  David Sedmera; Andy Wessels; Thomas C Trusk; Robert P Thompson; Kenneth W Hewett; Robert G Gourdie
Journal:  Am J Physiol Heart Circ Physiol       Date:  2006-05-05       Impact factor: 4.733

10.  Changes in wall motion and blood flow in the outflow tract of chick embryonic hearts observed with optical coherence tomography after outflow tract banding and vitelline-vein ligation.

Authors:  Sandra Rugonyi; Carley Shaut; Aiping Liu; Kent Thornburg; Ruikang K Wang
Journal:  Phys Med Biol       Date:  2008-08-22       Impact factor: 3.609

View more
  4 in total

1.  Multifunctional laser speckle imaging.

Authors:  E Du; Shuhao Shen; Shau Poh Chong; Nanguang Chen
Journal:  Biomed Opt Express       Date:  2020-03-13       Impact factor: 3.732

2.  Line-scanning SD-OCT for in-vivo, non-contact, volumetric, cellular resolution imaging of the human cornea and limbus.

Authors:  Le Han; Bingyao Tan; Zohreh Hosseinaee; Lin Kun Chen; Denise Hileeto; Kostadinka Bizheva
Journal:  Biomed Opt Express       Date:  2022-06-17       Impact factor: 3.562

Review 3.  Enhanced medical diagnosis for dOCTors: a perspective of optical coherence tomography.

Authors:  Rainer Leitgeb; Fabian Placzek; Elisabet Rank; Lisa Krainz; Richard Haindl; Qian Li; Mengyang Liu; Marco Andreana; Angelika Unterhuber; Tilman Schmoll; Wolfgang Drexler
Journal:  J Biomed Opt       Date:  2021-10       Impact factor: 3.758

4.  Accurate In Vivo Bowman's Thickness Measurement Using Mirau Ultrahigh Axial Resolution Line Field Optical Coherence Tomography.

Authors:  Samuel Lawman; Sharon Mason; Stephen B Kaye; Yao-Chun Shen; Yalin Zheng
Journal:  Transl Vis Sci Technol       Date:  2022-08-01       Impact factor: 3.048

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.