Literature DB >> 19494981

Parallel Fourier domain optical coherence tomography for in vivo measurement of the human eye.

Branislav Grajciar, Michael Pircher, Adolf Fercher, Rainer Leitgeb.   

Abstract

A parallel Frequency Domain Optical Coherence Tomography (FD-OCT) system and - to the best of our knowledge- first in vivo tomograms obtained with such system are presented. A full tomogram of 256(x) x 512(z) pixels covering a sample region of 8 mm x 3,8 mm is recorded in only 1 ms. Since the transverse as well as the depth information is obtained in parallel, the structure is free of any motion artifacts. In order to study cross talk issues for parallel illumination the transversal resolution for a thermal light source is compared to that with an SLD.

Entities:  

Year:  2005        PMID: 19494981     DOI: 10.1364/opex.13.001131

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  22 in total

1.  Snapshot 3D optical coherence tomography system using image mapping spectrometry.

Authors:  Thuc-Uyen Nguyen; Mark C Pierce; Laura Higgins; Tomasz S Tkaczyk
Journal:  Opt Express       Date:  2013-06-03       Impact factor: 3.894

2.  Parallel frequency-domain optical coherence tomography scatter-mode imaging of the hamster cheek pouch using a thermal light source.

Authors:  R N Graf; W J Brown; A Wax
Journal:  Opt Lett       Date:  2008-06-15       Impact factor: 3.776

3.  Megahertz streak-mode Fourier domain optical coherence tomography.

Authors:  Rui Wang; Julie X Yun; Xiaocong Yuan; Richard Goodwin; Roger R Markwald; Bruce Z Gao
Journal:  J Biomed Opt       Date:  2011-06       Impact factor: 3.170

4.  Line-field parallel swept source MHz OCT for structural and functional retinal imaging.

Authors:  Daniel J Fechtig; Branislav Grajciar; Tilman Schmoll; Cedric Blatter; Rene M Werkmeister; Wolfgang Drexler; Rainer A Leitgeb
Journal:  Biomed Opt Express       Date:  2015-02-04       Impact factor: 3.732

5.  Design and optimization of line-field optical coherence tomography at visible wavebands.

Authors:  Fangjian Xing; Jang-Hoon Lee; Collin Polucha; Jonghwan Lee
Journal:  Biomed Opt Express       Date:  2021-02-09       Impact factor: 3.732

6.  Twenty-five years of optical coherence tomography: the paradigm shift in sensitivity and speed provided by Fourier domain OCT [Invited].

Authors:  Johannes F de Boer; Rainer Leitgeb; Maciej Wojtkowski
Journal:  Biomed Opt Express       Date:  2017-06-15       Impact factor: 3.732

7.  Measurement of dynamic cell-induced 3D displacement fields in vitro for traction force optical coherence microscopy.

Authors:  Jeffrey A Mulligan; François Bordeleau; Cynthia A Reinhart-King; Steven G Adie
Journal:  Biomed Opt Express       Date:  2017-01-27       Impact factor: 3.732

8.  Reduction of frame rate in full-field swept-source optical coherence tomography by numerical motion correction [Invited].

Authors:  Clara Pfäffle; Hendrik Spahr; Dierck Hillmann; Helge Sudkamp; Gesa Franke; Peter Koch; Gereon Hüttmann
Journal:  Biomed Opt Express       Date:  2017-02-13       Impact factor: 3.732

9.  High-speed and high-sensitivity parallel spectral-domain optical coherence tomography using a supercontinuum light source.

Authors:  Jessica Barrick; Ana Doblas; Michael R Gardner; Patrick R Sears; Lawrence E Ostrowski; Amy L Oldenburg
Journal:  Opt Lett       Date:  2016-12-15       Impact factor: 3.776

10.  A Pico Projector Source for Confocal Fluorescence and Ophthalmic Imaging.

Authors:  Matthew S Muller
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2012-09-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.