Literature DB >> 29500818

A machine learning approach to the accurate prediction of monitor units for a compact proton machine.

Baozhou Sun1, Dao Lam1, Deshan Yang1, Kevin Grantham1, Tiezhi Zhang1, Sasa Mutic1, Tianyu Zhao1.   

Abstract

PURPOSE: Clinical treatment planning systems for proton therapy currently do not calculate monitor units (MUs) in passive scatter proton therapy due to the complexity of the beam delivery systems. Physical phantom measurements are commonly employed to determine the field-specific output factors (OFs) but are often subject to limited machine time, measurement uncertainties and intensive labor. In this study, a machine learning-based approach was developed to predict output (cGy/MU) and derive MUs, incorporating the dependencies on gantry angle and field size for a single-room proton therapy system. The goal of this study was to develop a secondary check tool for OF measurements and eventually eliminate patient-specific OF measurements.
METHOD: The OFs of 1754 fields previously measured in a water phantom with calibrated ionization chambers and electrometers for patient-specific fields with various range and modulation width combinations for 23 options were included in this study. The training data sets for machine learning models in three different methods (Random Forest, XGBoost and Cubist) included 1431 (~81%) OFs. Ten-fold cross-validation was used to prevent "overfitting" and to validate each model. The remaining 323 (~19%) OFs were used to test the trained models. The difference between the measured and predicted values from machine learning models was analyzed. Model prediction accuracy was also compared with that of the semi-empirical model developed by Kooy (Phys. Med. Biol. 50, 2005). Additionally, gantry angle dependence of OFs was measured for three groups of options categorized on the selection of the second scatters. Field size dependence of OFs was investigated for the measurements with and without patient-specific apertures.
RESULTS: All three machine learning methods showed higher accuracy than the semi-empirical model which shows considerably large discrepancy of up to 7.7% for the treatment fields with full range and full modulation width. The Cubist-based solution outperformed all other models (P < 0.001) with the mean absolute discrepancy of 0.62% and maximum discrepancy of 3.17% between the measured and predicted OFs. The OFs showed a small dependence on gantry angle for small and deep options while they were constant for large options. The OF decreased by 3%-4% as the field radius was reduced to 2.5 cm.
CONCLUSION: Machine learning methods can be used to predict OF for double-scatter proton machines with greater prediction accuracy than the most popular semi-empirical prediction model. By incorporating the gantry angle dependence and field size dependence, the machine learning-based methods can be used for a sanity check of OF measurements and bears the potential to eliminate the time-consuming patient-specific OF measurements.
© 2018 American Association of Physicists in Medicine.

Entities:  

Keywords:  machine learning; monitor units; output factor; proton therapy

Mesh:

Year:  2018        PMID: 29500818     DOI: 10.1002/mp.12842

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  11 in total

1.  Developing Predictive or Prognostic Biomarkers for Charged Particle Radiotherapy.

Authors:  Michael D Story; Jing Wang
Journal:  Int J Part Ther       Date:  2018

2.  Detecting Epileptic Seizures in EEG Signals with Complementary Ensemble Empirical Mode Decomposition and Extreme Gradient Boosting.

Authors:  Jiang Wu; Tengfei Zhou; Taiyong Li
Journal:  Entropy (Basel)       Date:  2020-01-24       Impact factor: 2.524

3.  Computer automation for physics chart check should be adopted in clinic to replace manual chart checking for radiotherapy.

Authors:  Edward L Clouser; Quan Chen; Yi Rong
Journal:  J Appl Clin Med Phys       Date:  2021-02-02       Impact factor: 2.102

Review 4.  Integration of AI and Machine Learning in Radiotherapy QA.

Authors:  Maria F Chan; Alon Witztum; Gilmer Valdes
Journal:  Front Artif Intell       Date:  2020-09-29

5.  Development of a Longitudinal Diagnosis and Prognosis in Patients with Chronic Kidney Disease: Intelligent Clinical Decision-Making Scheme.

Authors:  Chin-Chuan Shih; Ssu-Han Chen; Gin-Den Chen; Chi-Chang Chang; Yu-Lin Shih
Journal:  Int J Environ Res Public Health       Date:  2021-12-04       Impact factor: 3.390

6.  Development of Predictive Models in Patients with Epiphora Using Lacrimal Scintigraphy and Machine Learning.

Authors:  Yong-Jin Park; Ji Hoon Bae; Mu Heon Shin; Seung Hyup Hyun; Young Seok Cho; Yearn Seong Choe; Joon Young Choi; Kyung-Han Lee; Byung-Tae Kim; Seung Hwan Moon
Journal:  Nucl Med Mol Imaging       Date:  2019-02-07

7.  Development and evaluation of machine learning models for voxel dose predictions in online adaptive magnetic resonance guided radiation therapy.

Authors:  M Allan Thomas; Yabo Fu; Deshan Yang
Journal:  J Appl Clin Med Phys       Date:  2020-04-19       Impact factor: 2.102

8.  Prediction of the output factor using machine and deep learning approach in uniform scanning proton therapy.

Authors:  Hardev S Grewal; Michael S Chacko; Salahuddin Ahmad; Hosang Jin
Journal:  J Appl Clin Med Phys       Date:  2020-05-17       Impact factor: 2.102

9.  Developing a Novel Machine Learning-Based Classification Scheme for Predicting SPCs in Breast Cancer Survivors.

Authors:  Chi-Chang Chang; Ssu-Han Chen
Journal:  Front Genet       Date:  2019-09-18       Impact factor: 4.599

10.  Prediction of Left Ventricular Mechanics Using Machine Learning.

Authors:  Yaghoub Dabiri; Alex Van der Velden; Kevin L Sack; Jenny S Choy; Ghassan S Kassab; Julius M Guccione
Journal:  Front Phys       Date:  2019-09-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.