Daniel J Friedman1,2, Craig S Parzynski3, E Kevin Heist4, Andrea M Russo5, Joseph G Akar3, James V Freeman3, Jeptha P Curtis3, Sana M Al-Khatib6,2. 1. Division of Cardiology, Duke University Hospital, Durham, NC (D.J.F., S.M.A.-K.). daniel.friedman@duke.edu. 2. Duke Clinical Research Institute, Durham, NC (D.J.F., S.M.A.-K.). 3. Yale University School of Medicine, New Haven, CT (C.S.P., J.G.A., J.V.F., J.P.C.). 4. Cardiac Arrhythmia Service, Massachusetts General Hospital, Boston (E.K.H.). 5. Cooper Medical School of Rowan University, Camden, NJ (A.M.R.). 6. Division of Cardiology, Duke University Hospital, Durham, NC (D.J.F., S.M.A.-K.).
Abstract
BACKGROUND: Compared with transvenous implantable cardioverter defibrillators (ICDs), subcutaneous (S)-ICDs require a higher energy for effective defibrillation. Although ventricular fibrillation conversion testing (CT) is recommended after S-ICD implantation to ensure an adequate margin between the defibrillation threshold and maximum device output (80J), prior work found that adherence to this recommendation is declining. METHODS: We studied first-time recipients of S-ICDs (between September 28, 2012, and April 1, 2016) in the National Cardiovascular Database Registry ICD Registry to determine predictors of use of CT, predictors of an insufficient safety margin (ISM, defined as ventricular fibrillation conversion energy >65J) during testing, and inhospital outcomes associated with use of CT. Multivariable logistic regression analysis was used to predict use of CT and ISM. Inverse probability weighted logistic regression analysis was used to examine the association between use of CT and inhospital adverse events including death. RESULTS: CT testing was performed in 70.7% (n=5624) of 7960 patients with S-ICDs. Although deferral of CT was associated with several patient characteristics (including increased body mass index, increased body surface area, severely reduced ejection fraction, dialysis dependence, warfarin use, anemia, and hypertrophic cardiomyopathy), the facility effect was comparatively more important (area under the curve for patient level versus generalized linear mixed model: 0.619 versus 0.877). An ISM occurred in 6.9% (n=336) of 4864 patients without a prior ICD and was more common among white patients and those with ventricular pacing on the preimplant ECG, higher preimplant blood pressure, larger body surface area, higher body mass index, and lower ejection fraction. A risk score was able to identify patients at low (<5%), medium (5% to 10%), and high risk (>10%) for ISM. CT testing was not associated with a composite of inhospital complications including death. CONCLUSIONS: Use of CT testing after S-ICD implantation was driven by facility preference to a greater extent than patient factors and was not associated with a composite of inhospital complications or death. ISM was relatively uncommon and is associated with several widely available patient characteristics. These data may inform ICD system selection and a targeted approach to CT.
BACKGROUND: Compared with transvenous implantable cardioverter defibrillators (ICDs), subcutaneous (S)-ICDs require a higher energy for effective defibrillation. Although ventricular fibrillation conversion testing (CT) is recommended after S-ICD implantation to ensure an adequate margin between the defibrillation threshold and maximum device output (80J), prior work found that adherence to this recommendation is declining. METHODS: We studied first-time recipients of S-ICDs (between September 28, 2012, and April 1, 2016) in the National Cardiovascular Database Registry ICD Registry to determine predictors of use of CT, predictors of an insufficient safety margin (ISM, defined as ventricular fibrillation conversion energy >65J) during testing, and inhospital outcomes associated with use of CT. Multivariable logistic regression analysis was used to predict use of CT and ISM. Inverse probability weighted logistic regression analysis was used to examine the association between use of CT and inhospital adverse events including death. RESULTS:CT testing was performed in 70.7% (n=5624) of 7960 patients with S-ICDs. Although deferral of CT was associated with several patient characteristics (including increased body mass index, increased body surface area, severely reduced ejection fraction, dialysis dependence, warfarin use, anemia, and hypertrophic cardiomyopathy), the facility effect was comparatively more important (area under the curve for patient level versus generalized linear mixed model: 0.619 versus 0.877). An ISM occurred in 6.9% (n=336) of 4864 patients without a prior ICD and was more common among white patients and those with ventricular pacing on the preimplant ECG, higher preimplant blood pressure, larger body surface area, higher body mass index, and lower ejection fraction. A risk score was able to identify patients at low (<5%), medium (5% to 10%), and high risk (>10%) for ISM. CT testing was not associated with a composite of inhospital complications including death. CONCLUSIONS: Use of CT testing after S-ICD implantation was driven by facility preference to a greater extent than patient factors and was not associated with a composite of inhospital complications or death. ISM was relatively uncommon and is associated with several widely available patient characteristics. These data may inform ICD system selection and a targeted approach to CT.
Authors: S T Normand; M B Landrum; E Guadagnoli; J Z Ayanian; T J Ryan; P D Cleary; B J McNeil Journal: J Clin Epidemiol Date: 2001-04 Impact factor: 6.437
Authors: Bruce L Wilkoff; Laurent Fauchier; Martin K Stiles; Carlos A Morillo; Sana M Al-Khatib; Jesús Almendral; Luis Aguinaga; Ronald D Berger; Alejandro Cuesta; James P Daubert; Sergio Dubner; Kenneth A Ellenbogen; N A Mark Estes; Guilherme Fenelon; Fermin C Garcia; Maurizio Gasparini; David E Haines; Jeff S Healey; Jodie L Hurtwitz; Roberto Keegan; Christof Kolb; Karl-Heinz Kuck; Germanas Marinskis; Martino Martinelli; Mark McGuire; Luis G Molina; Ken Okumura; Alessandro Proclemer; Andrea M Russo; Jagmeet P Singh; Charles D Swerdlow; Wee Siong Teo; William Uribe; Sami Viskin; Chun-Chieh Wang; Shu Zhang Journal: Heart Rhythm Date: 2015-12-01 Impact factor: 6.343
Authors: Judith L Bonnes; Sjoerd W Westra; Leon H R Bouwels; Menko Jan DE Boer; Marc A Brouwer; Joep L R M Smeets Journal: J Cardiovasc Electrophysiol Date: 2016-03-09
Authors: Michael R Gold; Johan D Aasbo; Mikhael F El-Chami; Mark Niebauer; John Herre; Jordan M Prutkin; Bradley P Knight; Steven Kutalek; Kevin Hsu; Raul Weiss; Eric Bass; Michael Husby; Timothy M Stivland; Martin C Burke Journal: Heart Rhythm Date: 2017-05-11 Impact factor: 6.343
Authors: Daniel J Friedman; Craig S Parzynski; Paul D Varosy; Jordan M Prutkin; Kristen K Patton; Ali Mithani; Andrea M Russo; Jeptha P Curtis; Sana M Al-Khatib Journal: JAMA Cardiol Date: 2016-11-01 Impact factor: 14.676
Authors: Lucas Boersma; Craig Barr; Reinoud Knops; Dominic Theuns; Lars Eckardt; Petr Neuzil; Marcoen Scholten; Margaret Hood; Juergen Kuschyk; Paul Jones; Elizabeth Duffy; Michael Husby; Kenneth Stein; Pier D Lambiase Journal: J Am Coll Cardiol Date: 2017-08-15 Impact factor: 24.094
Authors: Jeff S Healey; Stefan H Hohnloser; Michael Glikson; Jorg Neuzner; Phillipe Mabo; Xavier Vinolas; Josef Kautzner; Gilles O'Hara; Lieselot VanErven; Fredrik Gadler; Janice Pogue; Ursula Appl; Jim Gilkerson; Thierry Pochet; Kenneth M Stein; Bela Merkely; Susan Chrolavicius; Brandi Meeks; Csaba Foldesi; Bernard Thibault; Stuart J Connolly Journal: Lancet Date: 2015-02-23 Impact factor: 79.321
Authors: Andrea M Russo; Yongfei Wang; Sana M Al-Khatib; Jeptha P Curtis; Rachel Lampert Journal: Pacing Clin Electrophysiol Date: 2013-08-26 Impact factor: 1.976
Authors: Emily P Zeitler; Daniel J Friedman; Zak Loring; Kristen B Campbell; Sarah A Goldstein; Zachary K Wegermann; Jane Schutz; Nicole Smith; Eric Black-Maier; Sana M Al-Khatib; Jonathan P Piccini Journal: Heart Rhythm Date: 2019-09-24 Impact factor: 6.343
Authors: Patrick H Pun; Craig S Parzynski; Daniel J Friedman; Gillian Sanders; Jeptha P Curtis; Sana M Al-Khatib Journal: Clin J Am Soc Nephrol Date: 2020-09-23 Impact factor: 8.237
Authors: Rohit J Timal; Veronique de Gucht; Joris I Rotmans; Liselotte C R Hensen; Maurits S Buiten; Mihaly K de Bie; Hein Putter; Martin J Schalij; Ton J Rabelink; J Wouter Jukema Journal: Qual Life Res Date: 2021-02-19 Impact factor: 4.147
Authors: Pier D Lambiase; Dominic A Theuns; Francis Murgatroyd; Craig Barr; Lars Eckardt; Petr Neuzil; Marcoen Scholten; Margaret Hood; Jȕrgen Kuschyk; Amy J Brisben; Nathan Carter; Timothy M Stivland; Reinoud Knops; Lucas V A Boersma Journal: Eur Heart J Date: 2022-06-01 Impact factor: 35.855