Literature DB >> 29455371

Cyclic fatigue resistance of R-Pilot, WaveOne Gold Glider, and ProGlider glide path instruments.

Cangül Keskin1, Uğur İnan2, Murat Demiral3, Ali Keleş2.   

Abstract

OBJECTIVE: The aim of the present study was to compare the cyclic fatigue resistance of R-Pilot (VDW; Munich, Germany) with ProGlider (Denstply Sirona; Ballaigues, Switzerland) and WaveOne Gold Glider (Denstply Sirona; Ballaigues, Switzerland) glide path instruments.
MATERIALS AND METHODS: R-Pilot, ProGlider, and WaveOne Gold Glider instruments were collected (n = 15) and tested in a dynamic cyclic fatigue test device, which has an artificial canal with 60° angle of curvature and a 5-mm radius of curvature. All instruments were operated until fracture occurred, and both time to fracture (TF) and the lengths of the fractured fragments were recorded. Mean and standard deviations of TF and fragment length were calculated for each reciprocating system. TF data and fractured fragment length data were subjected to one-way ANOVA and post-hoc Tukey tests (P < 0.05). Also a Weibull analysis was performed on TF data.
RESULTS: The cyclic fatigue resistance values of the WaveOne Gold Glider and R-Pilot were significantly higher than those of the ProGlider (P < 0.05), with no significant difference between them (P > 0.05). Weibull analysis revealed that WaveOne Gold Glider showed the highest predicted TF value for 99% survival rate, which was followed by R-Pilot and ProGlider. Regarding the length of the fractured tips, there were no significant differences among the instruments (P > 0.05).
CONCLUSIONS: The reciprocating WaveOne Gold Glider and R-Pilot instruments had significantly higher cyclic fatigue resistance than rotary ProGlider instruments. CLINICAL RELEVANCE: This study reported that novel reciprocating glide path instruments exhibited higher cyclic fatigue resistance than rotating glide path instrument.

Entities:  

Keywords:  Dynamic cyclic fatigue test model; Nickel-titanium; Pathfile management; Reciprocation

Mesh:

Year:  2018        PMID: 29455371     DOI: 10.1007/s00784-018-2391-4

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  29 in total

1.  Design improvement and failure reduction of endodontic files through finite element analysis: application to V-Taper file designs.

Authors:  Rui He; Jun Ni
Journal:  J Endod       Date:  2010-09       Impact factor: 4.171

2.  Influence of force location in orthodontic shear bond strength testing.

Authors:  Arndt Klocke; Bärbel Kahl-Nieke
Journal:  Dent Mater       Date:  2005-05       Impact factor: 5.304

3.  Effect of electropolishing ProFile nickel-titanium rotary instruments on cyclic fatigue resistance, torsional resistance, and cutting efficiency.

Authors:  Tung B Bui; John C Mitchell; J Craig Baumgartner
Journal:  J Endod       Date:  2008-02       Impact factor: 4.171

4.  Use of nickel-titanium rotary PathFile to create the glide path: comparison with manual preflaring in simulated root canals.

Authors:  Elio Berutti; Giuseppe Cantatore; Arnaldo Castellucci; Giorgio Chiandussi; Francesco Pera; Giuseppe Migliaretti; Damiano Pasqualini
Journal:  J Endod       Date:  2009-03       Impact factor: 4.171

5.  Flexibility and torsional behaviour of rotary nickel-titanium PathFile, RaCe ISO 10, Scout RaCe and stainless steel K-File hand instruments.

Authors:  R K L Nakagawa; J L Alves; V T L Buono; M G A Bahia
Journal:  Int Endod J       Date:  2013-07-02       Impact factor: 5.264

6.  Glide Path Enlargement of Mandibular Molar Canals by Using K-files, the ProGlider File, and G-Files: A Comparative Study of the Preparation Times.

Authors:  Farzana Paleker; Peet J van der Vyver
Journal:  J Endod       Date:  2017-02-09       Impact factor: 4.171

7.  Cyclic Fatigue Resistance of Reciproc Blue, Reciproc, and WaveOne Gold Reciprocating Instruments.

Authors:  Cangül Keskin; Uğur Inan; Murat Demiral; Ali Keleş
Journal:  J Endod       Date:  2017-06-27       Impact factor: 4.171

8.  In vitro comparison of cyclic fatigue resistance of ProTaper, WaveOne, and Twisted Files.

Authors:  Ricardo Castelló-Escrivá; Teresa Alegre-Domingo; Vicente Faus-Matoses; Sophie Román-Richon; Vicente J Faus-Llácer
Journal:  J Endod       Date:  2012-08-30       Impact factor: 4.171

9.  Fatigue Life of Reciproc and Mtwo instruments subjected to static and dynamic tests.

Authors:  Hélio P Lopes; Carlos N Elias; Márcia V B Vieira; José F Siqueira; Marcelo Mangelli; Weber S P Lopes; Victor T L Vieira; Flávio R F Alves; Julio C M Oliveira; Thaiane G Soares
Journal:  J Endod       Date:  2013-02-08       Impact factor: 4.171

10.  Dynamic Torsional and Cyclic Fracture Behavior of ProFile Rotary Instruments at Continuous or Reciprocating Rotation as Visualized with High-speed Digital Video Imaging.

Authors:  Daisuke Tokita; Arata Ebihara; Kana Miyara; Takashi Okiji
Journal:  J Endod       Date:  2017-06-01       Impact factor: 4.171

View more
  5 in total

1.  Comparison of postoperative pain intensity after using reciprocating and continuous rotary glide path systems: a randomized clinical trial.

Authors:  Mehmet Adıgüzel; Koray Yılmaz; Pelin Tüfenkçi
Journal:  Restor Dent Endod       Date:  2019-02-12

2.  Differences in cyclic fatigue lifespan between two different heat treated NiTi endodontic rotary instruments: WaveOne Gold vs EdgeOne Fire.

Authors:  Gianluca Gambarini; Massimo Galli; Dario Di Nardo; Marco Seracchiani; Orlando Donfrancesco; Luca Testarelli
Journal:  J Clin Exp Dent       Date:  2019-07-01

Review 3.  Cyclic Fatigue Resistance of Glide Path Rotary Files: A Systematic Review of in Vitro Studies.

Authors:  Israa Ashkar; José Luis Sanz; Leopoldo Forner
Journal:  Materials (Basel)       Date:  2022-09-26       Impact factor: 3.748

4.  Comparison of the ability of Reciproc and Reciproc Blue instruments to reach the full working length with or without glide path preparation.

Authors:  Mehmet Adıguzel; Pelin Tufenkci
Journal:  Restor Dent Endod       Date:  2018-11-01

5.  Cyclic fatigue resistance of the WaveOne Gold Glider, ProGlider, and the One G glide path instruments in double-curvature canals.

Authors:  Damla Kırıcı; Alper Kuştarcı
Journal:  Restor Dent Endod       Date:  2019-09-09
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.