Cyclic Fatigue Resistance of Reciproc Blue, Reciproc, and WaveOne Gold Reciprocating Instruments.

Cangül Keskin1, Uğur Inan2, Murat Demiral3, Ali Keleş2.   

Abstract

INTRODUCTION: The aim of the present study was to compare the cyclic fatigue resistance of Reciproc Blue R25 (VDW, Munich, Germany) with Reciproc R25 (VDW) and WaveOne Gold Primary (Denstply Maillefer, Ballaigues, Switzerland).
METHODS: Fifteen Reciproc Blue R25, 15 Reciproc R25, and 15 WaveOne Gold Primary instruments were collected and tested in a dynamic cyclic fatigue test device, which has an artificial canal with a 60° angle of curvature and a 5-mm radius of curvature. All instruments were operated until fracture occurred, and time to fracture (TF) and the lengths of the fractured fragments were recorded. The mean and standard deviations of TF and fragment length were calculated for each reciprocating system. TF data were subjected to Kruskal-Wallis 1-way analysis of variance and the Dunn test, whereas fractured fragment length data were subjected to 1-way analysis of variance (P < .05).
RESULTS: Reciproc Blue R25 exhibited the highest cyclic fatigue resistance (P < .05). The cyclic fatigue resistance values of WaveOne Gold Primary were significantly higher than those of Reciproc R25 (P < .05). There was no significant difference in the mean length of the fractured fragments among the instruments (P > .05).
CONCLUSIONS: Reciproc Blue R25 instruments had significantly higher cyclic fatigue resistance than WaveOne Gold and Reciproc R25 instruments.
Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Dynamic cyclic fatigue test model; nickel-titanium; reciprocation

Mesh:

Substances:

Year:  2017        PMID: 28662877     DOI: 10.1016/j.joen.2017.03.036

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  21 in total

1.  Shaping ability of reciprocating single-file systems in severely curved canals: WaveOne and Reciproc versus WaveOne Gold and Reciproc blue.

Authors:  Sebastian Bürklein; Stefanie Flüch; Edgar Schäfer
Journal:  Odontology       Date:  2018-05-18       Impact factor: 2.634

2.  Does the type of endodontic access influence in the cyclic fatigue resistance of reciprocating instruments?

Authors:  Emmanuel João Nogueira Leal Silva; Rafael Santos Attademo; Marcia Cristina Dutra da Silva; Karem Paula Pinto; Henrique Dos Santos Antunes; Victor Talarico Leal Vieira
Journal:  Clin Oral Investig       Date:  2020-11-21       Impact factor: 3.573

3.  Analysis of the Importance of the Motion Used in the Resistance of Different Mechanical Instrumentation Systems in Endodontics: A Comparative Study.

Authors:  Jesús Mena-Álvarez; Manuel Almanzor-López; Norberto Quispe-López; Ana De Pedro-Muñoz; Cristina Rico-Romano
Journal:  Materials (Basel)       Date:  2022-06-24       Impact factor: 3.748

4.  Cyclic fatigue using severely curved canals and torsional resistance of thermally treated reciprocating instruments.

Authors:  Emmanuel João Nogueira Leal Silva; Victor Talarico Leal Vieira; Fernanda Hecksher; Marja Ribeiro Silva Dos Santos Oliveira; Henrique Dos Santos Antunes; Edson Jorge Lima Moreira
Journal:  Clin Oral Investig       Date:  2018-02-01       Impact factor: 3.573

5.  Effect of canal curvature location on the cyclic fatigue resistance of reciprocating files.

Authors:  Tyler Sobotkiewicz; Xiangya Huang; Markus Haapasalo; Christophe Mobuchon; Ahmed Hieawy; Jinghao Hu; Huimin Zhou; Zhejun Wang; Ya Shen
Journal:  Clin Oral Investig       Date:  2020-06-02       Impact factor: 3.573

6.  Cyclic fatigue resistance of R-Pilot, WaveOne Gold Glider, and ProGlider glide path instruments.

Authors:  Cangül Keskin; Uğur İnan; Murat Demiral; Ali Keleş
Journal:  Clin Oral Investig       Date:  2018-02-17       Impact factor: 3.573

7.  Comparison of the shaping ability of novel thermally treated reciprocating instruments.

Authors:  Cangül Keskin; Murat Demiral; Evren Sarıyılmaz
Journal:  Restor Dent Endod       Date:  2018-03-03

8.  Shaping ability of Reciproc Blue reciprocating instruments with or without glide path in simulated S-shaped root canals.

Authors:  Cangul Keskin; Evren Sarıyılmaz; Murat Demiral
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2018-03-14

9.  Torsional Behavior of WaveOne Gold Endodontic File with the Dedicated Motor of the Original WaveOne File.

Authors:  Jung-Hong Ha; Asgeir Sigurdsson; Gustavo De-Deus; Antheunis Versluis; Sang Won Kwak; Hyeon-Cheol Kim
Journal:  Materials (Basel)       Date:  2018-07-06       Impact factor: 3.623

10.  Comparison of the ability of Reciproc and Reciproc Blue instruments to reach the full working length with or without glide path preparation.

Authors:  Mehmet Adıguzel; Pelin Tufenkci
Journal:  Restor Dent Endod       Date:  2018-11-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.