Literature DB >> 29446319

Dual-energy CT iodine maps as an alternative quantitative imaging biomarker to abdominal CT perfusion: determination of appropriate trigger delays for acquisition using bolus tracking.

Stephan Skornitzke1, Franziska Fritz1, Philipp Mayer1, Marco Koell1, Jens Hansen1, Gregor Pahn1, Thilo Hackert2, Hans-Ulrich Kauczor1, Wolfram Stiller1.   

Abstract

OBJECTIVE: Quantitative evaluation of different bolus tracking trigger delays for acquisition of dual energy (DE) CT iodine maps as an alternative to CT perfusion.
METHODS: Prior to this retrospective analysis of prospectively acquired data, DECT perfusion sequences were dynamically acquired in 22 patients with pancreatic carcinoma using dual source CT at 80/140 kVp with tin filtration. After deformable motion-correction, perfusion maps of blood flow (BF) were calculated from 80 kVp image series of DECT, and iodine maps were calculated for each of the 34 DECT acquisitions per patient. BF and iodine concentrations were measured in healthy pancreatic tissue and carcinoma. To evaluate potential DECT acquisition triggered by bolus tracking, measured iodine concentrations from the 34 DECT acquisitions per patient corresponding to different trigger delays were assessed for correlation to BF and intergroup differences between tissue types depending on acquisition time.
RESULTS: Average BF measured in healthy pancreatic tissue and carcinoma was 87.6 ± 28.4 and 38.6 ± 22.2 ml/100 ml min-1, respectively. Correlation between iodine concentrations and BF was statistically significant for bolus tracking with trigger delay greater than 0 s (rmax = 0.89; p < 0.05). Differences in iodine concentrations between healthy pancreatic tissue and carcinoma were statistically significant for DECT acquisitions corresponding to trigger delays of 15-21 s (p < 0.05).
CONCLUSION: An acquisition window between 15 and 21 s after exceeding bolus tracking threshold shows promising results for acquisition of DECT iodine maps as an alternative to CT perfusion measurements of BF. Advances in knowledge: After clinical validation, DECT iodine maps of pancreas acquired using bolus tracking with appropriate trigger delay as determined in this study could offer an alternative quantitative imaging biomarker providing functional information for tumor assessment at reduced patient radiation exposure compared to CT perfusion measurements of BF.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29446319      PMCID: PMC6190794          DOI: 10.1259/bjr.20170351

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  21 in total

1.  Dual-energy computed-tomography cholangiography in potential donors for living-related liver transplantation: initial experience.

Authors:  Christof M Sommer; Christoph B Schwarzwaelder; Wolfram Stiller; Sebastian T Schindera; Tobias Heye; Ulrike Stampfl; Stefanie Ramsauer; Nadine Bellemann; Juergen Weitz; Jan Schmidt; Lars Grenacher; Hans U Kauczor; Boris A Radeleff
Journal:  Invest Radiol       Date:  2010-07       Impact factor: 6.016

2.  Measurement of tissue perfusion by dynamic computed tomography.

Authors:  K A Miles
Journal:  Br J Radiol       Date:  1991-05       Impact factor: 3.039

Review 3.  Dual energy CT: preliminary observations and potential clinical applications in the abdomen.

Authors:  Anno Graser; Thorsten R C Johnson; Hersh Chandarana; Michael Macari
Journal:  Eur Radiol       Date:  2008-08-02       Impact factor: 5.315

4.  Energy-selective reconstructions in X-ray computerized tomography.

Authors:  R E Alvarez; A Macovski
Journal:  Phys Med Biol       Date:  1976-09       Impact factor: 3.609

5.  Qualitative and quantitative evaluation of rigid and deformable motion correction algorithms using dual-energy CT images in view of application to CT perfusion measurements in abdominal organs affected by breathing motion.

Authors:  S Skornitzke; F Fritz; M Klauss; G Pahn; J Hansen; J Hirsch; L Grenacher; H-U Kauczor; W Stiller
Journal:  Br J Radiol       Date:  2014-12-03       Impact factor: 3.039

6.  CT effective dose per dose length product using ICRP 103 weighting factors.

Authors:  Walter Huda; Dennise Magill; Wenjun He
Journal:  Med Phys       Date:  2011-03       Impact factor: 4.071

7.  Pancreatic-phase versus portal vein-phase helical CT of the pancreas: optimal temporal window for evaluation of pancreatic adenocarcinoma.

Authors:  G W Boland; M E O'Malley; M Saez; C Fernandez-del-Castillo; A L Warshaw; P R Mueller
Journal:  AJR Am J Roentgenol       Date:  1999-03       Impact factor: 3.959

8.  Perfusion CT best predicts outcome after radioembolization of liver metastases: a comparison of radionuclide and CT imaging techniques.

Authors:  Fabian Morsbach; Bert-Ram Sah; Lea Spring; Gilbert Puippe; Sonja Gordic; Burkhardt Seifert; Niklaus Schaefer; Thomas Pfammatter; Hatem Alkadhi; Caecilia S Reiner
Journal:  Eur Radiol       Date:  2014-05-12       Impact factor: 5.315

9.  [Hydro-CT in detection and staging of pancreatic carcinoma].

Authors:  G M Richter; C Wunsch; B Schneider; M Düx; E Klar; R Seelos; G W Kauffmann
Journal:  Radiologe       Date:  1998-04       Impact factor: 0.635

10.  Iodine concentration as a perfusion surrogate marker in oncology: Further elucidation of the underlying mechanisms using Volume Perfusion CT with 80 kVp.

Authors:  Wolfgang M Thaiss; Ulrike Haberland; Sascha Kaufmann; Daniel Spira; Christoph Thomas; Konstantin Nikolaou; Marius Horger; Alexander W Sauter
Journal:  Eur Radiol       Date:  2015-12-17       Impact factor: 5.315

View more
  7 in total

1.  Evaluation of the effect of image noise on CT perfusion measurements using digital perfusion phantoms.

Authors:  Stephan Skornitzke; Jessica Hirsch; Hans-Ulrich Kauczor; Wolfram Stiller
Journal:  Eur Radiol       Date:  2018-10-11       Impact factor: 5.315

Review 2.  Dual-energy CT: theoretical principles and clinical applications.

Authors:  Andrea Agostini; Alessandra Borgheresi; Alberto Mari; Chiara Floridi; Federico Bruno; Marina Carotti; Nicolò Schicchi; Antonio Barile; Stefania Maggi; Andrea Giovagnoni
Journal:  Radiol Med       Date:  2019-12-02       Impact factor: 3.469

3.  Improving Structure Delineation for Radiation Therapy Planning Using Dual-Energy CT.

Authors:  George Noid; Justin Zhu; An Tai; Nilesh Mistry; Diane Schott; Douglas Prah; Eric Paulson; Christopher Schultz; X Allen Li
Journal:  Front Oncol       Date:  2020-08-28       Impact factor: 6.244

4.  Detection of Incomplete Irreversible Electroporation (IRE) and Microwave Ablation (MWA) of Hepatocellular Carcinoma (HCC) Using Iodine Quantification in Dual Energy Computed Tomography (DECT).

Authors:  Wolf Bäumler; Lukas Philipp Beyer; Lukas Lürken; Philipp Wiggermann; Christian Stroszczynski; Marco Dollinger; Andreas Schicho
Journal:  Diagnostics (Basel)       Date:  2022-04-14

5.  Quantitative contrast enhanced dual energy CT to predict avascular necrosis: a feasibility study of proximal humerus fractures.

Authors:  Kevin B Hoover; Alexandria O Starks; Valentina Robila; Daniel L Riddle
Journal:  BMC Med Imaging       Date:  2021-12-11       Impact factor: 1.930

6.  Spectral Detector CT-Derived Pulmonary Perfusion Maps and Pulmonary Parenchyma Characteristics for the Semiautomated Classification of Pulmonary Hypertension.

Authors:  Roman Johannes Gertz; Felix Gerhardt; Jan Robert Kröger; Rahil Shahzad; Liliana Caldeira; Jonathan Kottlors; Nils Große Hokamp; David Maintz; Stephan Rosenkranz; Alexander Christian Bunck
Journal:  Front Cardiovasc Med       Date:  2022-02-28

7.  Diagnostic Effectiveness of Dual Source Dual Energy Computed Tomography for Benign and Malignant Thyroid Nodules.

Authors:  Tong Zhu; Kanglin Xie; Chongxiao Wang; Linkui Wang; Wei Liu; Faping Zhang
Journal:  Evid Based Complement Alternat Med       Date:  2022-08-17       Impact factor: 2.650

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.