Literature DB >> 20458249

Dual-energy computed-tomography cholangiography in potential donors for living-related liver transplantation: initial experience.

Christof M Sommer1, Christoph B Schwarzwaelder, Wolfram Stiller, Sebastian T Schindera, Tobias Heye, Ulrike Stampfl, Stefanie Ramsauer, Nadine Bellemann, Juergen Weitz, Jan Schmidt, Lars Grenacher, Hans U Kauczor, Boris A Radeleff.   

Abstract

OBJECTIVES: To report our initial experience with dual-energy computed-tomography (CT) cholangiography in potential donors for living-related liver transplantation.
MATERIALS AND METHODS: Seventeen potential donors for living-related liver transplantation (6 women and 11 men; average age 37.8 +/- 10.4 years) underwent contrast-enhanced dual-energy CT cholangiography. A dual-energy CT scan of the liver was carried out with acquisition of 2 raw datasets at tube currents of 140 and 80 kV, respectively. A third weighted average dataset were obtained (weighting ratio: 70% 140 kV, 30% 80 kV). Pure iodine images (fourth dataset) and contrast-optimized images (fifth dataset) were reconstructed. Analysis of all datasets comprised determination of bile duct visualization scores (on a scale of 1 to 4: 1, not visualized; 2, faintly seen; 3, identified but the origin or portions of the duct are not visualized; and 4, excellent visualization from origin to branches), maximum bile duct diameters, bile duct attenuation, and liver parenchyma attenuation as well as image noise, signal-to-noise ratio, and contrast-to-noise ratio.
RESULTS: Highest maximum bile duct diameters were detected for optimized-contrast images and the 80 kV dataset, intermediate for pure iodine images and the weighted average dataset and lowest for the 140 kV dataset with significant differences. Highest bile duct attenuation was detected for optimized-contrast images (535.7 +/- 148.3 HU) and the 80 kV dataset (533.7 +/- 145.9 HU) with significant differences compared with pure iodine images (344.9 +/- 106.5 HU) and the weighted average dataset (355.5 +/- 87.6 HU) (P < 0.001). Highest image noise was detected for the 80 kV dataset (39.3 +/- 5.4 HU) with significant differences compared with the optimized-contrast images (31.5 +/- 4.0) (P < 0.001). Highest signal-to-noise ratio and contrast-to-noise ratio were detected for pure iodine images (18.3 +/- 7.1 and 17.6 +/- 7.0) and optimized-contrast images (17.3 +/- 5.8 and 14.8 +/- 5.5) with significant differences compared with the 80 kV dataset (14.0 +/- 5.2 and 11.8 +/- 4.8) and the weighted average dataset (15.1 +/- 4.4 and 12.1 +/- 4.1) (P < 0.001 and P < 0.01).
CONCLUSIONS: Dual-energy CT cholangiography in potential donors for living-related liver transplantation is remarkable. Pure iodine images and contrast-optimized images allow precise analysis of the biliary system with increased image quality compared with conventional images. Contrast-optimized images should be used for detection and localization of the bile ducts and pure iodine images for quantitative description of the anatomic dimensions of the biliary segments.

Entities:  

Mesh:

Year:  2010        PMID: 20458249     DOI: 10.1097/RLI.0b013e3181dfdabd

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  5 in total

1.  Which should be the routine cross-sectional reconstruction mode in spectral CT imaging: monochromatic or polychromatic?

Authors:  Y Cui; S-Y Gao; Z-L Wang; X-T Li; Y-S Sun; L Tang; X-P Zhang
Journal:  Br J Radiol       Date:  2012-06-20       Impact factor: 3.039

2.  Dual-energy CT iodine maps as an alternative quantitative imaging biomarker to abdominal CT perfusion: determination of appropriate trigger delays for acquisition using bolus tracking.

Authors:  Stephan Skornitzke; Franziska Fritz; Philipp Mayer; Marco Koell; Jens Hansen; Gregor Pahn; Thilo Hackert; Hans-Ulrich Kauczor; Wolfram Stiller
Journal:  Br J Radiol       Date:  2018-03-07       Impact factor: 3.039

3.  Hypodense liver lesions in patients with hepatic steatosis: do we profit from dual-energy computed tomography?

Authors:  Johanna Nattenmüller; Waldemar Hosch; Tri-Thien Nguyen; Stephan Skornitzke; Andreas Jöres; Lars Grenacher; Hans-Ulrich Kauczor; Christof M Sommer; Wolfram Stiller
Journal:  Eur Radiol       Date:  2015-05-17       Impact factor: 5.315

4.  Determinants of second-order bile duct visualization at CT cholangiography in potential living liver donors.

Authors:  Alexander W Keedy; Richard S Breiman; Emily M Webb; John P Roberts; Fergus V Coakley; Benjamin M Yeh
Journal:  AJR Am J Roentgenol       Date:  2013-05       Impact factor: 3.959

5.  Renal cyst pseudoenhancement: intraindividual comparison between virtual monochromatic spectral images and conventional polychromatic 120-kVp images obtained during the same CT examination and comparisons among images reconstructed using filtered back projection, adaptive statistical iterative reconstruction, and model-based iterative reconstruction.

Authors:  Yoshitake Yamada; Minoru Yamada; Koichi Sugisawa; Hirotaka Akita; Eisuke Shiomi; Takayuki Abe; Shigeo Okuda; Masahiro Jinzaki
Journal:  Medicine (Baltimore)       Date:  2015-04       Impact factor: 1.889

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.